Endoleaks after endovascular repair of abdominal aortic aneurysm: value of CEUS

被引:0
作者
R. Iezzi
A. R. Cotroneo
R. Basilico
A. Simeone
M. L. Storto
L. Bonomo
机构
[1] Institute of Radiology,Department of Bioimaging and Radiological Sciences
[2] “A. Gemelli” Hospital,Department of Clinical Science and Bioimaging, Section of Radiology
[3] Catholic University,undefined
[4] University “G. D’Annunzio”,undefined
来源
Abdominal Imaging | 2010年 / 35卷
关键词
Abdominal aortic aneurysm; Computed tomography; Endovascular repair; Endoleaks; Ultrasonography; Contrast-enhanced ultrasonography;
D O I
暂无
中图分类号
学科分类号
摘要
Endovascular repair (EVAR) is playing an increasingly role in the treatment of abdominal aortic aneurysm. A successful procedure depends on the complete sealing of the aneurysm sac from blood flow to achieve general pressure relief and avoid aneurysm rupture, with a shrinkage of the aneurysm sac. The most common complication of EVAR is endoleak that is the persistence of perigraft flow within the aneurysm sac, which has to be considered the major cause of enlargement and rupture of the aneurysm, and the main indication for surgical late conversion. For this reason, strict surveillance of these patients is mandatory for the early detection of endoleaks and the preferred method of follow-up is represented by CT angiography. However, CTA has limitations. The investigation is repeated several times, making radiation exposure a necessary concern. Therefore, it would be useful to have another reliable diagnostic examination during follow-up. Color duplex ultrasound is non-invasive, does not use radiation or contrast medium, is less expensive, easy to perform and widely available. However, this technique obtained poor results in terms of sensitivity in the detection of endoleaks. In the last years, the introduction of ultrasound contrast agents and contrast-specific imaging has, however, rekindled interest in this modality and its potential for replacing of CTA in routine surveillance. The purpose of this review is to highlight the diagnostic value of CEUS in the post-EVAR endoleaks detection.
引用
收藏
页码:106 / 114
页数:8
相关论文
共 50 条
  • [1] Endoleaks after endovascular repair of abdominal aortic aneurysm: value of CEUS
    Iezzi, R.
    Cotroneo, A. R.
    Basilico, R.
    Simeone, A.
    Storto, M. L.
    Bonomo, L.
    ABDOMINAL IMAGING, 2010, 35 (01): : 106 - 114
  • [2] Effect of endoleaks on changes in aortoiliac volume after endovascular repair for abdominal aortic aneurysm
    Meinel, Felix G.
    Haack, Mareike
    Weidenhagen, Rolf
    Hellbach, Katharina
    Rottenkolber, Marietta
    Armbruster, Marco
    Jerkku, Thomas
    Thierfelder, Kolja M.
    Pluma, Jessica L. V.
    Koeppelb, Thomas A.
    Rubind, Geoffrey D.
    Sommera, Wieland H.
    CLINICAL HEMORHEOLOGY AND MICROCIRCULATION, 2016, 64 (02) : 135 - 147
  • [3] Endoleaks after endovascular abdominal aortic aneurysm repair: what one needs to know
    Schloesser, Felix J. V.
    Muhs, Bart E.
    CURRENT OPINION IN CARDIOLOGY, 2012, 27 (06) : 598 - 603
  • [4] Percutaneous Transabdominal Approach for the Treatment of Endoleaks after Endovascular Repair of Infrarenal Abdominal Aortic Aneurysm
    Choi, Sun Young
    Won, Jong Yun
    Lee, Do Yun
    Choi, Donghoon
    Shim, Won-Heum
    Lee, Kwang-Hun
    KOREAN JOURNAL OF RADIOLOGY, 2010, 11 (01) : 107 - 114
  • [5] Cyanoacrylate embolization of endoleaks after abdominal aortic aneurysm repair
    Buckenham, Timothy
    McKewen, Michael
    Laing, Andrew
    Roake, Justin
    Lewis, David
    Gordon, Malcolm K.
    ANZ JOURNAL OF SURGERY, 2009, 79 (11) : 841 - 843
  • [6] Length of abdominal aortic aneurysm and incidence of endoleaks type II after endovascular repair
    Dinh Dong Nghi Phan
    Frank Meyer
    Maciej Pech
    Zuhir Halloul
    Wiener klinische Wochenschrift, 2015, 127 : 851 - 857
  • [7] Length of abdominal aortic aneurysm and incidence of endoleaks type II after endovascular repair
    Dinh Dong Nghi Phan
    Meyer, Frank
    Pech, Maciej
    Halloul, Zuhir
    WIENER KLINISCHE WOCHENSCHRIFT, 2015, 127 (21-22) : 851 - 857
  • [8] Treatment of endoleaks after endovascular abdominal aorta aneurysm repair
    Duman, Enes
    Cifci, Egemen
    Yildirim, Erkan
    Boyvat, Fatih
    TURK GOGUS KALP DAMAR CERRAHISI DERGISI-TURKISH JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2016, 24 (03): : 569 - 572
  • [9] Imaging of endoleaks after endovascular aneurysm repair (EVAR) with contrast-enhanced ultrasound (CEUS)
    Clevert, D-A.
    Horng, A.
    Kopp, R.
    Schick, K.
    Meimarakis, G.
    Sommer, W. H.
    Reiser, M.
    RADIOLOGE, 2009, 49 (11): : 1033 - 1039
  • [10] Endoleaks After Endovascular Abdominal Aortic Aneurysm Repair: Management Strategies According to CT Findings
    Bashir, Mustafa R.
    Ferral, Hector
    Jacobs, Chad
    McCarthy, Walter
    Goldin, Marshall
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2009, 192 (04) : W178 - W186