New acquisitions in the assessment of breath-by-breath alveolar gas transfer in humans

被引:0
作者
M. Cautero
P. E. di Prampero
C. Capelli
机构
[1] University of Udine,Dipartimento di Scienze e Tecnologie Biomediche, School of Medicine
[2] Microgravity-Ageing-Training-Immobility (MATI) Center of Excellence,undefined
来源
European Journal of Applied Physiology | 2003年 / 90卷
关键词
Breath-by-breath O; uptake; Breath-by-breath CO; output; Alveolar gas changes; Exercise; O; uptake kinetics;
D O I
暂无
中图分类号
学科分类号
摘要
We summarise recent results obtained in testing some of the algorithms utilised for estimating breath-by-breath (BB) alveolar O2 transfer (VO2A) in humans. VO2A is the difference of the O2 volume transferred at the mouth minus the alveolar O2 stores changes. These are given by the alveolar volume change at constant O2 fraction (FAiO2 ΔVAi) plus the O2 alveolar fraction change at constant volume [VAi−1(FAi−FAi−1)O2], where VAi−1 is the alveolar volume at the beginning of the breath i. All these quantities can be measured BB, with the exception of VAi−1, which is usually set equal to the subject’s functional residual capacity (FRC) (Auchincloss algorithm, AU). Alternatively, the respiratory cycle can be defined as the time elapsing between two equal O2 fractions in two subsequent breaths (Grønlund algorithm, GR). In this case, FAiO2=FAi−1O2 and the term VAi−1(FAi−FAi−1)O2 disappears. BB alveolar gas transfer was first determined at rest and during exercise at steady-state. AU and GR showed the same accuracy in estimating alveolar gas transfer; however GR turned out to be significantly more precise than AU. Secondly, the effects of using different VAi−1 values in estimating the time constant of alveolar O2 uptake (V̇O2A) kinetics at the onset of 120 W step exercise were evaluated. V̇O2A was calculated by using GR and by using (in AU) VAi−1 values ranging from 0 to FRC +0.5 l. The time constant of the phase II kinetics (τ2) of V̇O2A increased linearly, with VAi−1 ranging from 36.6 s for VAi−1=0 to 46.8 s for VAi−1=FRC+0.5 l, whereas τ2 amounted to 34.3 s with GR. We concluded that, when using AU in estimating V̇O2A during step exercise transitions, the τ2 value obtained depends on the assumed value of VAi−1.
引用
收藏
页码:231 / 241
页数:10
相关论文
共 37 条
[1]  
Auchincloss JH(1966)Effect of ventilation on oxygen transfer during early exercise J Appl Physiol: 21 810-818
[2]  
Gilbert R(1991)The regulation of respiration and circulation during the initial stages of muscular work J Appl Physiol 71 2099-136
[3]  
Baule GH(1968)Dynamics of pulmonary gas exchange and heart rate at start and end of exercise J Appl Physiol 21 390-68
[4]  
Barstow A(1973)Breath-by-breath estimate of alveolar gas transfer variability in man at rest and during exercise J Appl Physiol 34 128-475
[5]  
Beaver J(1981)Inferences from pulmonary O2 uptake with respect to intramuscular [phosphocreatine] kinetics during moderate exercise in humans J Appl Physiol 51 1662-932
[6]  
Beaver D(1997)Regional differences in gas exchange in the lung of erect man J Appl Physiol 82 1963-989
[7]  
Beaver PE(2001)undefined Pflugers Arch 441 566-undefined
[8]  
Busso CL(2002)undefined Eur J Appl Physiol 88 203-undefined
[9]  
Capelli HB(1976)undefined J Appl Physiol 41 474-undefined
[10]  
Cautero SA(1983)undefined J Appl Physiol 55 583-undefined