The measurement of tibial torsion by magnetic resonance imaging in children: the comparison of three different methods

被引:8
|
作者
Basaran S.H. [1 ]
Ercin E. [2 ]
Bayrak A. [2 ]
Cumen H. [2 ]
Bilgili M.G. [2 ]
Inci E. [3 ]
Avkan M.C. [2 ]
机构
[1] Department of Orthopaedics and Traumatology, Faculty of Medicine, Karabuk University, Balıklarkayası Mevkii, Karabuk
[2] Orthopaedics and Traumatology Clinic, Bakırkoy Dr. Sadi Konuk Research and Training Hospital, Istanbul
[3] Radiology Clinic, Bakırkoy Dr. Sadi Konuk Research and Training Hospital, Istanbul
关键词
Children; Magnetic resonance imaging; Reliability; Tibial torsion;
D O I
10.1007/s00590-015-1694-2
中图分类号
学科分类号
摘要
Background: There is no consensus about the measurement techniques to determine the tibial torsion by using MRI. The primary research question of this study was to find out which MRI-based tibial torsion measurement method is more reliable and reproducible. Secondly, we compared tibial torsion values measured by three measurement methods in T1- and T2-weighted images. Methods: We retrospectively analyzed voluntary children performed MRI for determination of the lower limb torsional alignment after the surgical treatment between January 2013 and December 2013. Thirty-four extremities of 17 patients were included in the present study. The mean age of patients was 7.3 years (range 3–12 years). The transmalleolar, posterior intermalleolar and anterior talus angles were used for the measurement of tibial torsion. All tibial torsion measurements were calculated by three blinded observers in T1- and T2-weighted images, and these measurements were repeated blindly after 2 months. Results: All measured intra- and interobserver intra-class correlations were greater than 0.60. The best scores were achieved with the anterior talus angle. It was followed by the posterior malleolar angle and the intermalleolar angle, respectively. Furthermore, there were no statistically significant differences between tibial torsion values measured by each observer in T1- and T2-weighted images of each method. Conclusion: MRI-based tibial torsion measurements were reliable and reproducible for all three methods. But we think that the anterior talus angle and the posterior malleolar angle are easier and more successful in determination of the tibial torsion. Also, both T1- and T2-weighted images can be used successfully for this purpose. © 2015, Springer-Verlag France.
引用
收藏
页码:1327 / 1332
页数:5
相关论文
共 50 条
  • [1] Evaluation of Different Methods for Measuring Lateral Tibial Slope Using Magnetic Resonance Imaging
    Lipps, David B.
    Wilson, Annie M.
    Ashton-Miller, James A.
    Wojtys, Edward M.
    AMERICAN JOURNAL OF SPORTS MEDICINE, 2012, 40 (12) : 2731 - 2736
  • [2] Prospective, randomised comparison of two intravenous sedation methods for magnetic resonance imaging in children
    Brzozka, Viktor Mark
    Piotrowski, Andrzej Jerzy
    ANAESTHESIOLOGY INTENSIVE THERAPY, 2023, 55 (02) : 81 - 86
  • [3] Tibial cartilage volume measurement in knee osteoarthritis using magnetic resonance imaging
    Vanichtantikul, Varalee
    Hongvilai, Sarit
    Numkarunarunrote, Numphung
    ASIAN BIOMEDICINE, 2015, 9 (01) : 41 - 47
  • [4] Comparison of Two Different Intranasal Doses of Dexmedetomidine in Children for Magnetic Resonance Imaging Sedation
    Aslihan Tug
    Ayse Hanci
    Hacer Sebnem Turk
    Ferda Aybey
    Canan Tulay Isil
    Pinar Sayin
    Sibel Oba
    Pediatric Drugs, 2015, 17 : 479 - 485
  • [5] Magnetic resonance imaging measurement of the anorectal striated muscle complex in normal children
    Tang, Shaotao
    Tong, Qiangsong
    Mao, Yongzhong
    Wang, Yong
    Li, Shiwang
    Cao, Zhiqing
    Ruan, Qinglan
    JOURNAL OF PEDIATRIC SURGERY, 2006, 41 (09) : 1549 - 1555
  • [6] Magnetic resonance imaging in children with implants
    Camilo Jaimes
    Diane Biaggotti
    Gayathri Sreedher
    Apeksha Chaturvedi
    Michael M. Moore
    Amy R. Danehy
    Pediatric Radiology, 2021, 51 : 748 - 759
  • [7] Proximal tibial epiphysis in magnetic resonance imaging
    Jopp, E.
    Schroeder, I.
    Maas, R.
    Adam, G.
    Pueschel, K.
    RECHTSMEDIZIN, 2010, 20 (06) : 464 - 468
  • [8] Magnetic resonance imaging findings in adnexial torsion
    Castro Trindade, Ronald Meira
    Baroni, Ronaldo Hueb
    Rosemberg, Michelle
    de Quadros, Marianne Siquara
    Jorge Racy, Marcelo de Castro
    Tachibana, Adriano
    de Gusmao Funari, Marcelo Buarque
    EINSTEIN-SAO PAULO, 2010, 8 (01): : 92 - 96
  • [9] Femoral and Tibial Torsion Measurement in Children and Adolescents: Comparison of 3D Models Based on Low- Dose Biplanar Radiography and LowDose CT
    Rosskopf, Andrea B.
    Ramseier, Leonhard E.
    Sutter, Reto
    Pfirrmann, Christian W. A.
    Buck, Florian M.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2014, 202 (03) : W285 - W291
  • [10] Magnetic resonance imaging of experimental testicular torsion
    Kaipia, A
    Ryymin, P
    Mäkelä, E
    Aaltonen, M
    Kähärä, V
    Kangasniemi, M
    INTERNATIONAL JOURNAL OF ANDROLOGY, 2005, 28 (06): : 355 - 359