A review on synchrophasor communication system: communication technologies, standards and applications

被引:45
作者
Appasani B. [1 ]
Mohanta D.K. [2 ]
机构
[1] School of Electronics Engineering, KIIT University, Bhubaneswar
[2] Department Electrical and Electronics Engineering, Birla Institute of Technology, Mesra
关键词
Communication standards; Communication technologies; Optimal placement; Phasor measurement unit; Synchrophasor communication system; Wide area measurement system;
D O I
10.1186/s41601-018-0110-4
中图分类号
学科分类号
摘要
The present-day power system is a complex network that caters to the demands of several applications with diverse energy requirements. Such a complex network is susceptible to faults caused due to several reasons such as the failure of the equipment, hostile weather conditions, etc. These faults if not detected in the real-time may lead to cascading failures resulting in a blackout. These blackouts have catastrophic consequences which result in a huge loss of resources. For example, a blackout in 2004 caused an economic loss of 10 billion U.S dollars as per the report of the Electricity Consumers Resource Council. Subsequent investigation of the blackout revealed that the catastrophe could have been prevented if there was an early warning system. Similar other blackouts across the globe forced the power system engineers to devise an effective solution for real-time monitoring and control of the power system. The consequence of these efforts is the wide area measurement system (WAMS). The WAMS consists of several sensors known as the phasor measurement units (PMUs) that collect the real information pertaining to the health of the power grid. This information in the form time synchronized voltage and current phasors is communicated to the central control center or the phasor data concentrator (PDC) where the data is analyzed for detection of power system anomalies. The communication of the synchrophasor data from each PMU to the PDC constitutes the synchrophasor communication system (SPCS). Thus, the SPCS can be considered as the edifice of the WAMS and its reliable operation is essential for the effective monitoring and control of the power system. This paper presents a comprehensive review of the various synchrophasor communication technologies, communication standards and applications. It also identifies the existing knowledge gaps and the scope for future research work. © 2018, The Author(s).
引用
收藏
相关论文
共 115 条
  • [1] Pourbeik P., Kundur P.S., Taylor C.W., The anatomy of a power grid blackout - root causes and dynamics of recent major blackouts, IEEE Power and Energy Magazine, 4, 5, pp. 22-29, (2006)
  • [2] Phadke A.G., The wide world of wide-area measurement, IEEE Power and Energy Magazine, 6, 5, pp. 52-65, (2008)
  • [3] Phadke A.G., Thorp J.S., Synchronized phasor measurements and their applications, (2008)
  • [4] New Delhi: Central Electricity Regulation Commission, (2016)
  • [5] Mohanta D.K., Cherukuri M., Roy D.S., A brief review of phasor measurement units as sensors for smart grid, Electric Power Components & Systems, 44, 4, pp. 411-425, (2016)
  • [6] Murthy C., Varma K.A., Roy D.S., Mohanta D.K., Reliability evaluation of phasor measurement unit using Type-2 fuzzy set theory, IEEE Systems Journal, 8, 4, pp. 1302-1309, (2014)
  • [7] Zurawski R., From wireline to wireless networks and technologies, IEEE Transactions on Industrial Informatics, 3, 2, pp. 93-94, (2007)
  • [8] Deng Y., Lin H., Phadke A.G., Shukla S., Thorp J.S., Networking technologies for wide-area measurement applications, Smart Grid Communications and Networking, pp. 205-233, (2012)
  • [9] Khan R.H., Khan J.Y., A comprehensive review of the application characteristics and traffic requirements of a smart grid communications network, Computer Networks, 57, 3, pp. 825-845, (2013)
  • [10] Berger L., Schwager A., Escudero-Garzas J., Power line Communications for Smart Grid Applications, Journal of Electrical and Computer Engineering, 2013, pp. 1-16, (2013)