Behaviour of cold-formed steel built-up closed columns composed by angle profiles

被引:0
作者
Aruna G. [1 ]
Sukumar S. [2 ]
Karthika V. [3 ]
机构
[1] Department of Civil Engineering, CMR Institute of Technology, Hyderabad
[2] Department of Civil Engineering, Paavai College of Engineering, Namakkal, Tamil Nadu
[3] Department of Civil Engineering, Jai Shriram Group of Institution, Tiruppur, Tamil Nadu
关键词
Columns; Distortional buckling; Finite-element analysis; Flexural buckling; Local buckling;
D O I
10.1007/s42107-019-00164-8
中图分类号
学科分类号
摘要
This paper presents the experimental investigation of cold-formed built-up closed sections with intermediate web stiffeners under axial compression with hinged end conditions. The specimens were formed using two angle sections with edge and intermediate stiffeners, connected by self-tapping screws. Three series of tests were conducted by varying the width of the intermediate web element. Twelve columns were tested by varying the column length. The specimens were failed by local, flexural, and interaction of these buckling modes. Non-linear Finite-element Analysis (FEA) was carried out using ANSYS. FEA results were compared with the experimental results. It is observed that FEA results closely resemble to experimental results. An extensive parametric study was carried out using validated finite-element model by varying the cross-sectional geometries of cold-formed built-up closed section with intermediate stiffeners. The column strengths predicted from the FEA was compared with the design strengths calculated using the AISI specification of cold-formed steel structures. The reliability of the current design method was assessed by reliability analysis. © 2019, Springer Nature Switzerland AG.
引用
收藏
页码:1037 / 1048
页数:11
相关论文
共 32 条
[21]  
Schafer B.W., Pekoz T., Computational modeling of cold-formed steel: characterizing geometric imperfections and residual stresses, Journal of Constructional Steel Research, 47, pp. 193-210, (1998)
[22]  
Stone T.A., Laboube R.A., Behavior of cold-formed steel built-up I-sections, Thin-Walled Structures, 43, pp. 185-1817, (2005)
[23]  
Sukumar S., Parameswaran P., Jayagopal L.S., Local-, distortional- and euler-buckling of thin walled built-up open sections under compression, Journal of Structural Engineering, SERC India, 32, 6, pp. 447-454, (2006)
[24]  
Ting T.C.H., Roy K., Lau H.H., Lim B.P., Effect of screw spacing on behavior of axially loaded back-to-back cold formed steel built-up channel section, Advances in Structural Engineering, (2017)
[25]  
Whittle J., Ramseyer C., Buckling capacities of axially loaded, cold-formed, built-up C-channels, Thin-Walled Structures, 47, pp. 190-201, (2009)
[26]  
Yan J., Young B., Column test of cold-formed steel channels with complex stiffeners, Journal of Structural Engineering, 128, 6, pp. 737-745, (2002)
[27]  
Yong B., Chen J., Column test of cold-formed steel non-symmetric lipped angle sections, Journal of Constructional Steel Research, 64, pp. 808-815, (2008)
[28]  
Young B., Chen J., Design of cold-formed steel built-up closed sections with intermediate stiffeners, Journal of Structural Engineering, 134, 5, pp. 727-737, (2008)
[29]  
Young B., Ellobody E., Design of cold-formed steel unequal angle compression members, Thin-Walled Structures, 45, pp. 330-338, (2007)
[30]  
Young B., Hancock G.J., Tests of cold-formed channels with local and distortional buckling, Journal of Structural Engineering, 117, 7, pp. 1789-1803, (1992)