Determination of129I in ambient air by inductively coupled plasma mass spectrometry (ICP/MS)

被引:0
|
作者
O. T. Farmer
C. J. Barinaga
D. W. Koppenaal
机构
[1] Pacific Northwest National Laboratory,
来源
Journal of Radioanalytical and Nuclear Chemistry | 1998年 / 234卷
关键词
Precipitation; Mass Spectrometry; Water Sample; Radionuclide; Inductively Couple Plasma Mass Spectrometry;
D O I
暂无
中图分类号
学科分类号
摘要
The detection of129I by Inductively Coupled Plasma Mass Spectrometry (ICP/MS) in environmental samples can be used to determine anthropogenic release of this long-lived radionuclide, which is a definitive indicator of certain nuclear activities. By using selective precipitation techniques with on-line ICP/MS detection, low levels of129I can be detected. The major interference for the ICP/MS detection of129I is due the presence of natural129Xe found in water samples at a concentration of about 1 ng/ml. This work will demonstrate a instrument detection of less than 50 fg129I from environmental air samples and shows promise for a rugged ICP/MS technique to monitor129I levels in ambient air for nonproliferation monitoring purposes.
引用
收藏
页码:153 / 158
页数:5
相关论文
共 50 条
  • [1] Determination of 129I in ambient air by inductively coupled plasma mass spectrometry (ICP/MS)
    Farmer, OT
    Barinaga, CJ
    Koppenaal, DW
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 1998, 234 (1-2) : 153 - 157
  • [2] Neptunium determination by inductively coupled plasma mass spectrometry (ICP-MS)
    D. E. Vance
    V. F. Belt
    T. J. Oatts
    D. K. Mann
    Journal of Radioanalytical and Nuclear Chemistry, 1998, 234 : 143 - 147
  • [3] Determination of plutonium by inductively coupled plasma mass spectrometry (ICP-MS)
    Tonouchi, S
    Habuki, H
    Katoh, K
    Yamazaki, K
    Hashimoto, T
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2002, 252 (02) : 367 - 371
  • [4] Determination of plutonium by inductively coupled plasma mass spectrometry (ICP-MS)
    S. Tonouchi
    H. Habuki
    K. Katoh
    K. Yamazaki
    T. Hashimoto
    Journal of Radioanalytical and Nuclear Chemistry, 2002, 252 : 367 - 371
  • [5] Determination of arsenic in blood and stomach contents by inductively coupled plasma/mass spectrometry (ICP/MS)
    Tanaka, T
    Hara, K
    Tanimoto, A
    Kasai, K
    Kita, T
    Tanaka, N
    Takayasu, T
    FORENSIC SCIENCE INTERNATIONAL, 1996, 81 (01) : 43 - 50
  • [6] Determination of trace elements in marine plankton by inductively coupled plasma mass spectrometry (ICP-MS)
    Z. Arslan
    N. Ertas
    J. F. Tyson
    P. C. Uden
    E. R. Denoyer
    Fresenius' Journal of Analytical Chemistry, 2000, 366 : 273 - 282
  • [7] An investigation of different modifiers in electrothermal vaporization inductively coupled plasma mass spectrometry (ETV-ICP-MS)
    K. Grünke
    H.-J. Stärk
    R. Wennrich
    H. M. Ortner
    J. A. C. Broekaert
    Fresenius' Journal of Analytical Chemistry, 1997, 359 : 465 - 468
  • [8] Inductively coupled plasma mass spectrometric (ICP/MS) determination of thallium in soils and winter rapeseeds
    Medek, P
    Pavlícková, J
    Zbíral, J
    Cizmárová, E
    Kubán, V
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 2001, 81 (03) : 207 - 219
  • [9] Determination of selenium in red blood cells by inductively coupled plasma mass spectrometry (ICP-MS) after microwave digestion
    U. Tinggi
    T. Gianduzzo
    R. Francis
    D. Nicol
    M. Shahin
    P. Scheelings
    Journal of Radioanalytical and Nuclear Chemistry, 2004, 259 : 469 - 472
  • [10] Capabilities and limitations of high-resolution - Inductively coupled plasma - Mass spectrometry (ICP-MS)
    Moor, C
    Devos, W
    Bissig, C
    CHIMIA, 2001, 55 (1-2) : 26 - 29