Static and Dynamic Analysis of Osteoarthritic and Orthotic Human Knee

被引:0
作者
Daniela Tarnita
Doina Pisla
Ionut Geonea
Calin Vaida
Marius Catana
Danut Nicolae Tarnita
机构
[1] University of Craiova,Faculty of Mechanics
[2] Technical University Cluj Napoca,CESTER
[3] INAS, Research Centre for the Robot Simulation and Testing
[4] University of Medicine and Pharmacy Craiova & Emergency Hospital Craiova,undefined
来源
Journal of Bionic Engineering | 2019年 / 16卷
关键词
osteoarthritic knee; bioinspired orthosis; finite element method; gait stability; Lyapunov exponents;
D O I
暂无
中图分类号
学科分类号
摘要
The first objective of this paper is to study the influence of the orthotic device on the maximum values of stresses in knee cartilages by using Ansys Workbench 14.5 software and applying the Finite Element Analysis (FEA) on a virtual assembly composed by an orthotic device and osteoarthritic knee (OAK). The second objective consists into quantifying and investigating the nonlinear motion of the human knee joint for OAK patients, with and without the orthotic device mounted on OAK, using tools of dynamics stability analysis. The short Lyapunov Exponents (LEs) are calculated, as measures of human knee and ankle joints stability, based on the experimental time series collected by using the biometrics acquisition system during walking on horizontal and inclined treadmills from a sample of healthy subjects and a sample of patients suffering by OAK disease. The values of LEs obtained for OAK patients are larger on the inclined treadmill than on horizontal treadmill and are larger than those obtained for healthy knees, being associated with more divergence and less stability. The results confirm that the influence of an orthotic device mounted on OAK on its stability is significant, the values obtained for LEs being smaller than those calculated for OAK, and closer to the values of normal knees of patients and of healthy subjects.
引用
收藏
页码:514 / 525
页数:11
相关论文
共 129 条
  • [1] Tarnita D(2016)Wearable sensors used for human gait analysis Romanian Journal of Morphology Embryology 57 373-382
  • [2] Yakhdani H F(2010)Stability and variability of knee kinematics during gait in knee osteoarthritis before and after replacement surgery Clinical Biomechanics 25 230-236
  • [3] Bafghi H A(2007)Biomechanical features of gait waveform data associated with knee osteoarthritis. An application of principal component analysis Gait & Posture 25 86-93
  • [4] Meijer O(2004)Reports of joint instability in knee osteoarthritis: Its prevalence and relationship to physical function Arthritis & Rheumatism 51 941-946
  • [5] Bruijn S(2009)Variability analysis of lower extremity joint kinematics during walking in healthy young adults Medical Engineering & Physics 31 784-792
  • [6] van den Dikkenberg N(2005)Powered lower limb orthoses for gait rehabilitation Topics in Spinal Cord Injury Rehabilitation 11 34-49
  • [7] Stibbe A B(2014)On the kinematics of a new parallel robot for brachytherapy Proceedings of the Romanian Academy A 15 354-361
  • [8] van Royeng B J(2008)A low-cost easy-operation hexa-pod walking machine International Journal of Advanced Robotic Systems 5 161-166
  • [9] van Dien J H(2008)A mechanical design of a low-cost easy-operation anthropomorphic wheeled leg for walking machines International Journal Robotica & Management 9 3-8
  • [10] Deluzio K J(2003)The bone and joint decade 2000–2010 Bulletin of the World Health Organization 81 629-S103