A High Performance Pulsatile Pump for Aortic Flow Experiments in 3-Dimensional Models

被引:0
作者
Rafeed A. Chaudhury
Victor Atlasman
Girish Pathangey
Nicholas Pracht
Ronald J. Adrian
David H. Frakes
机构
[1] Arizona State University,School of Biological and Health Systems Engineering
[2] Arizona State University,School of Electrical, Computer, and Energy Engineering
[3] Arizona State University,School for Engineering of Matter, Transport and Energy
来源
Cardiovascular Engineering and Technology | 2016年 / 7卷
关键词
Piston pump; Flow loop; Pulsatile flow; Blood flow; Aorta; Physiological waveform; Heart valves;
D O I
暂无
中图分类号
学科分类号
摘要
Aortic pathologies such as coarctation, dissection, and aneurysm represent a particularly emergent class of cardiovascular diseases. Computational simulations of aortic flows are growing increasingly important as tools for gaining understanding of these pathologies, as well as for planning their surgical repair. In vitro experiments are required to validate the simulations against real world data, and the experiments require a pulsatile flow pump system that can provide physiologic flow conditions characteristic of the aorta. We designed a newly capable piston-based pulsatile flow pump system that can generate high volume flow rates (850 mL/s), replicate physiologic waveforms, and pump high viscosity fluids against large impedances. The system is also compatible with a broad range of fluid types, and is operable in magnetic resonance imaging environments. Performance of the system was validated using image processing-based analysis of piston motion as well as particle image velocimetry. The new system represents a more capable pumping solution for aortic flow experiments than other available designs, and can be manufactured at a relatively low cost.
引用
收藏
页码:148 / 158
页数:10
相关论文
共 32 条
  • [31] Magnetic Resonance-Derived 3-Dimensional Blood Flow Patterns in the Main Pulmonary Artery as a Marker of Pulmonary Hypertension and a Measure of Elevated Mean Pulmonary Arterial Pressure
    Reiter, Gert
    Reiter, Ursula
    Kovacs, Gabor
    Kainz, Bernhard
    Schmidt, Karin
    Maier, Robert
    Olschewski, Horst
    Rienmueller, Rainer
    CIRCULATION-CARDIOVASCULAR IMAGING, 2008, 1 (01) : 23 - 30
  • [32] Flow Assessment Through Four Heart Valves Simultaneously Using 3-Dimensional 3-Directional Velocity-Encoded Magnetic Resonance Imaging With Retrospective Valve Tracking in Healthy Volunteers and Patients With Valvular Regurgitation
    Roes, Stijntje D.
    Hammer, Sebastiaan
    van der Geest, Rob J.
    Marsan, Nina Ajmone
    Bax, Jeroen J.
    Lamb, Hildo J.
    Reiber, Johan H. C.
    de Roos, Albert
    Westenberg, Jos J. M.