A High Performance Pulsatile Pump for Aortic Flow Experiments in 3-Dimensional Models

被引:0
作者
Rafeed A. Chaudhury
Victor Atlasman
Girish Pathangey
Nicholas Pracht
Ronald J. Adrian
David H. Frakes
机构
[1] Arizona State University,School of Biological and Health Systems Engineering
[2] Arizona State University,School of Electrical, Computer, and Energy Engineering
[3] Arizona State University,School for Engineering of Matter, Transport and Energy
来源
Cardiovascular Engineering and Technology | 2016年 / 7卷
关键词
Piston pump; Flow loop; Pulsatile flow; Blood flow; Aorta; Physiological waveform; Heart valves;
D O I
暂无
中图分类号
学科分类号
摘要
Aortic pathologies such as coarctation, dissection, and aneurysm represent a particularly emergent class of cardiovascular diseases. Computational simulations of aortic flows are growing increasingly important as tools for gaining understanding of these pathologies, as well as for planning their surgical repair. In vitro experiments are required to validate the simulations against real world data, and the experiments require a pulsatile flow pump system that can provide physiologic flow conditions characteristic of the aorta. We designed a newly capable piston-based pulsatile flow pump system that can generate high volume flow rates (850 mL/s), replicate physiologic waveforms, and pump high viscosity fluids against large impedances. The system is also compatible with a broad range of fluid types, and is operable in magnetic resonance imaging environments. Performance of the system was validated using image processing-based analysis of piston motion as well as particle image velocimetry. The new system represents a more capable pumping solution for aortic flow experiments than other available designs, and can be manufactured at a relatively low cost.
引用
收藏
页码:148 / 158
页数:10
相关论文
共 32 条
  • [1] A High Performance Pulsatile Pump for Aortic Flow Experiments in 3-Dimensional Models
    Chaudhury, Rafeed A.
    Atlasman, Victor
    Pathangey, Girish
    Pracht, Nicholas
    Adrian, Ronald J.
    Frakes, David H.
    CARDIOVASCULAR ENGINEERING AND TECHNOLOGY, 2016, 7 (02) : 148 - 158
  • [2] SIMULATION OF 3-DIMENSIONAL PULSATILE FLOW-THROUGH AN ASYMMETRIC STENOSIS
    DVINSKY, AS
    OJHA, M
    MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1994, 32 (02) : 138 - 142
  • [3] Experimental and computational study of pulsatile flow characteristics in Romanesque and gothic aortic arch models
    Zhang, Yan
    Zhang, Ruihang
    Thomas, Nick
    Ullah, Al Habib
    Eichholz, Benjamin
    Estevadeordal, Jordi
    Suzen, Yildirim Bora
    MEDICAL ENGINEERING & PHYSICS, 2022, 102
  • [4] Experimental analysis of pulsatile flow characteristics in prosthetic aortic valve models with stenosis
    Zhang, Ruihang
    Zhang, Yan
    MEDICAL ENGINEERING & PHYSICS, 2020, 79 : 10 - 18
  • [5] Collapse in high-grade stenosis during pulsatile flow experiments
    Kobayashi, S
    Tang, DL
    Ku, DN
    JSME INTERNATIONAL JOURNAL SERIES C-MECHANICAL SYSTEMS MACHINE ELEMENTS AND MANUFACTURING, 2004, 47 (04) : 1010 - 1018
  • [6] Altered Aortic 3-Dimensional Hemodynamics in Patients With Functionally Unicuspid Aortic Valves
    Ma, Liliana E.
    Vali, Alireza
    Blanken, Carmen
    Barker, Alex J.
    Malaisrie, Chris
    McCarthy, Patrick
    Collins, Jeremy D.
    Carr, James C.
    Schnell, Susanne
    Markl, Michael
    CIRCULATION-CARDIOVASCULAR IMAGING, 2018, 11 (08)
  • [7] Body perfusion during adult cardiopulmonary bypass is improved by pulsatile flow with intra-aortic balloon pump
    Onorati, F.
    Santarpino, G.
    Rubino, A. S.
    Caroleo, S.
    Dardano, A.
    Scalas, C.
    Gulletta, E.
    Santangelo, E.
    Renzulli, A.
    INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 2009, 32 (01) : 50 - 61
  • [8] Intra-aortic balloon pump-induced pulsatile flow reduces coagulative and fibrinolytic response to cardiopulmonary bypass
    Onorati, Francesco
    Esposito, Antonio
    Comi, Maria Caterina
    Impiombato, Barbara
    Cristodoro, Lucia
    Mastroroberto, Pasquale
    Renzulli, Attilio
    ARTIFICIAL ORGANS, 2008, 32 (06) : 433 - 441
  • [9] Time-resolved, 3-dimensional magnetic resonance flow analysis at 3 T: Visualization of normal and pathological aortic vascular Hemodynamics
    Frydrychowicz, Alex
    Harloff, Andreas
    Jung, Bernd
    Zaitsev, Maxim
    Weigang, Ernst
    Bley, Thorsten A.
    Langer, Mathias
    Hennig, Juergen
    Markl, Michael
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2007, 31 (01) : 9 - 15
  • [10] Effect of Curvature on Displacement Forces Acting on Aortic Endografts: A 3-Dimensional Computational Analysis
    Figueroa, C. Alberto
    Taylor, Charles A.
    Yeh, Victoria
    Chiou, Allen J.
    Zarins, Christopher K.
    JOURNAL OF ENDOVASCULAR THERAPY, 2009, 16 (03) : 284 - 294