Characterization of arterial plaque composition with dual energy computed tomography: a simulation study

被引:0
作者
Huanjun Ding
Chenggong Wang
Shant Malkasian
Travis Johnson
Sabee Molloi
机构
[1] University of California,Department of Radiological Sciences
来源
The International Journal of Cardiovascular Imaging | 2021年 / 37卷
关键词
Dual energy; CT; Plaque; Material decomposition;
D O I
暂无
中图分类号
学科分类号
摘要
To investigate the feasibility of quantifying the chemical composition of coronary artery plaque in terms of water, lipid, protein, and calcium contents using dual-energy computed tomography (CT) in a simulation study. A CT simulation package was developed based on physical parameters of a clinical CT scanner. A digital thorax phantom was designed to simulate coronary arterial plaques in the range of 2–5 mm in diameter. Both non-calcified and calcified plaques were studied. The non-calcified plaques were simulated as a mixture of water, lipid, and protein, while the calcified plaques also contained calcium. The water, lipid, protein, and calcium compositions of the plaques were selected to be within the expected clinical range. A total of 95 plaques for each lesion size were simulated using the CT simulation package at 80 and 135 kVp. Half-value layer measurements were made to make sure the simulated dose was within the range of clinical dual energy scanning protocols. Dual-energy material decomposition using a previously developed technique was performed to determine the volumetric fraction of water, lipid, protein, and calcium contents in each plaque. For non-calcified plaque, the total volume conservation provides the third constrain for three-material decomposition with dual energy CT. For calcified plaque, a fourth criterion was introduced from a previous report suggesting a linear correlation between water and protein contents in soft tissue. For non-calcified plaque, the root mean-squared error (RMSE) of the image-based decomposition was estimated to be 0.7%, 1.5%, and 0.3% for water, lipid, and protein contents, respectively. As for the calcified plaques, the RMSE of the 5 mm plaques were estimated to be 5.6%, 5.7%, 0.2%, and 3.1%, for water, lipid, calcium, and protein contents, respectively. The RMSE increases as the plaque size reduces. The simulation results indicate that chemical composition of coronary arterial plaques can be quantified using dual-energy CT. By accurately quantifying the content of a coronary plaque lesion, our decomposition method may provide valuable insight for the assessment and stratification of coronary artery disease.
引用
收藏
页码:331 / 341
页数:10
相关论文
共 50 条
[1]   Characterization of arterial plaque composition with dual energy computed tomography: a simulation study [J].
Ding, Huanjun ;
Wang, Chenggong ;
Malkasian, Shant ;
Johnson, Travis ;
Molloi, Sabee .
INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2021, 37 (01) :331-341
[2]   Evaluation of cholesterol crystals in carotid plaque by dual energy computed tomography [J].
Saito, Takuya ;
Endo, Hidenori ;
Ando, Daisuke ;
Miyagi, Itsuki ;
Kawabata, Yuichi ;
Watanabe, Mika ;
Saito, Atsushi ;
Fujimura, Miki ;
Yazawa, Yukako .
NEURORADIOLOGY, 2023, 65 (05) :979-982
[3]   Non-Calcified Coronary Artery Plaque Characterization by Dual-Energy Computed Tomography [J].
Haghighi, Rezvan Ravanfar ;
Chatterjee, Sabyasachi ;
Vani, Vardahan C. ;
Kumar, Pratik ;
Tabin, Milo ;
Ray, Ruma ;
Jalli, Reza ;
Sefidbakht, Sepide ;
Zarei, Fariba ;
Shakibafard, Ali Reza ;
Bardeji, Somayeh Gholami ;
Dodangeh, Mahdi ;
Bijan, Bijan .
IRANIAN JOURNAL OF RADIOLOGY, 2018, 15 (02)
[4]   Spectral Signal Density of Carotid Plaque Using Dual-Energy Computed Tomography [J].
Reynoso, Exequiel ;
Rodriguez-Granillo, Gaston A. ;
Capunay, Carlos ;
Deviggiano, Alejandro ;
Meli, Francisco ;
Carrascosa, Patricia .
JOURNAL OF NEUROIMAGING, 2017, 27 (05) :511-516
[5]   Evaluation of cholesterol crystals in carotid plaque by dual energy computed tomography [J].
Takuya Saito ;
Hidenori Endo ;
Daisuke Ando ;
Itsuki Miyagi ;
Yuichi Kawabata ;
Mika Watanabe ;
Atsushi Saito ;
Miki Fujimura ;
Yukako Yazawa .
Neuroradiology, 2023, 65 :979-982
[6]   Dual energy exposure control (DEEC) for computed tomography: Algorithm and simulation study [J].
Stenner, Philip ;
Kachelriess, Marc .
MEDICAL PHYSICS, 2008, 35 (11) :5054-5060
[7]   Measurement of breast tissue composition with dual energy cone-beam computed tomography: A postmortem study [J].
Ding, Huanjun ;
Ducote, Justin L. ;
Molloi, Sabee .
MEDICAL PHYSICS, 2013, 40 (06)
[8]   Algorithm for using dual energy computed tomography to determine chemical composition: A feasibility study [J].
Choi, Dong Hyeok ;
Ahn, So Hyun ;
Park, Kwangwoo ;
Han, Min Cheol ;
Kim, Jin Sung .
PLOS ONE, 2025, 20 (06)
[9]   Differentiation of Atherosclerotic Carotid Plaque Components With Dual-Energy Computed Tomography [J].
Aizaz, Mueez ;
Bierens, Juul ;
Gijbels, Marion J. J. ;
Schreuder, Tobien H. C. M. L. ;
van Orshoven, Narender P. ;
Daemen, Jan-Willem H. C. ;
Mess, Werner H. ;
Flohr, Thomas ;
van Oostenbrugge, Robert J. ;
Postma, Alida A. ;
Kooi, M. Eline .
INVESTIGATIVE RADIOLOGY, 2025, 60 (08) :508-516
[10]   Male Gender and Arterial Hypertension are Plaque Predictors at Coronary Computed Tomography Angiography [J].
Menezes Oliveira, Joselina Luzia ;
Hirata, Mario Hiroyuki ;
de Moraes Rego Sousa, Amanda Guerra ;
Gabriel, Fabiola Santos ;
Crespo Hirata, Thiago Dominguez ;
Tavares, Irlaneide da Silva ;
Melo, Luiza Dantas ;
Doria, Fabiana de Santana ;
Sobral Sousa, Antonio Carlos ;
Francisco Pinto, Ibraim Masciarelli .
ARQUIVOS BRASILEIROS DE CARDIOLOGIA, 2015, 104 (05) :409-416