Characterization of arterial plaque composition with dual energy computed tomography: a simulation study

被引:0
|
作者
Huanjun Ding
Chenggong Wang
Shant Malkasian
Travis Johnson
Sabee Molloi
机构
[1] University of California,Department of Radiological Sciences
来源
The International Journal of Cardiovascular Imaging | 2021年 / 37卷
关键词
Dual energy; CT; Plaque; Material decomposition;
D O I
暂无
中图分类号
学科分类号
摘要
To investigate the feasibility of quantifying the chemical composition of coronary artery plaque in terms of water, lipid, protein, and calcium contents using dual-energy computed tomography (CT) in a simulation study. A CT simulation package was developed based on physical parameters of a clinical CT scanner. A digital thorax phantom was designed to simulate coronary arterial plaques in the range of 2–5 mm in diameter. Both non-calcified and calcified plaques were studied. The non-calcified plaques were simulated as a mixture of water, lipid, and protein, while the calcified plaques also contained calcium. The water, lipid, protein, and calcium compositions of the plaques were selected to be within the expected clinical range. A total of 95 plaques for each lesion size were simulated using the CT simulation package at 80 and 135 kVp. Half-value layer measurements were made to make sure the simulated dose was within the range of clinical dual energy scanning protocols. Dual-energy material decomposition using a previously developed technique was performed to determine the volumetric fraction of water, lipid, protein, and calcium contents in each plaque. For non-calcified plaque, the total volume conservation provides the third constrain for three-material decomposition with dual energy CT. For calcified plaque, a fourth criterion was introduced from a previous report suggesting a linear correlation between water and protein contents in soft tissue. For non-calcified plaque, the root mean-squared error (RMSE) of the image-based decomposition was estimated to be 0.7%, 1.5%, and 0.3% for water, lipid, and protein contents, respectively. As for the calcified plaques, the RMSE of the 5 mm plaques were estimated to be 5.6%, 5.7%, 0.2%, and 3.1%, for water, lipid, calcium, and protein contents, respectively. The RMSE increases as the plaque size reduces. The simulation results indicate that chemical composition of coronary arterial plaques can be quantified using dual-energy CT. By accurately quantifying the content of a coronary plaque lesion, our decomposition method may provide valuable insight for the assessment and stratification of coronary artery disease.
引用
收藏
页码:331 / 341
页数:10
相关论文
共 50 条
  • [1] Characterization of arterial plaque composition with dual energy computed tomography: a simulation study
    Ding, Huanjun
    Wang, Chenggong
    Malkasian, Shant
    Johnson, Travis
    Molloi, Sabee
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2021, 37 (01) : 331 - 341
  • [2] Evaluation of cholesterol crystals in carotid plaque by dual energy computed tomography
    Saito, Takuya
    Endo, Hidenori
    Ando, Daisuke
    Miyagi, Itsuki
    Kawabata, Yuichi
    Watanabe, Mika
    Saito, Atsushi
    Fujimura, Miki
    Yazawa, Yukako
    NEURORADIOLOGY, 2023, 65 (05) : 979 - 982
  • [3] Non-Calcified Coronary Artery Plaque Characterization by Dual-Energy Computed Tomography
    Haghighi, Rezvan Ravanfar
    Chatterjee, Sabyasachi
    Vani, Vardahan C.
    Kumar, Pratik
    Tabin, Milo
    Ray, Ruma
    Jalli, Reza
    Sefidbakht, Sepide
    Zarei, Fariba
    Shakibafard, Ali Reza
    Bardeji, Somayeh Gholami
    Dodangeh, Mahdi
    Bijan, Bijan
    IRANIAN JOURNAL OF RADIOLOGY, 2018, 15 (02)
  • [4] Spectral Signal Density of Carotid Plaque Using Dual-Energy Computed Tomography
    Reynoso, Exequiel
    Rodriguez-Granillo, Gaston A.
    Capunay, Carlos
    Deviggiano, Alejandro
    Meli, Francisco
    Carrascosa, Patricia
    JOURNAL OF NEUROIMAGING, 2017, 27 (05) : 511 - 516
  • [5] Evaluation of cholesterol crystals in carotid plaque by dual energy computed tomography
    Takuya Saito
    Hidenori Endo
    Daisuke Ando
    Itsuki Miyagi
    Yuichi Kawabata
    Mika Watanabe
    Atsushi Saito
    Miki Fujimura
    Yukako Yazawa
    Neuroradiology, 2023, 65 : 979 - 982
  • [6] Dual energy exposure control (DEEC) for computed tomography: Algorithm and simulation study
    Stenner, Philip
    Kachelriess, Marc
    MEDICAL PHYSICS, 2008, 35 (11) : 5054 - 5060
  • [7] Measurement of breast tissue composition with dual energy cone-beam computed tomography: A postmortem study
    Ding, Huanjun
    Ducote, Justin L.
    Molloi, Sabee
    MEDICAL PHYSICS, 2013, 40 (06)
  • [8] Male Gender and Arterial Hypertension are Plaque Predictors at Coronary Computed Tomography Angiography
    Menezes Oliveira, Joselina Luzia
    Hirata, Mario Hiroyuki
    de Moraes Rego Sousa, Amanda Guerra
    Gabriel, Fabiola Santos
    Crespo Hirata, Thiago Dominguez
    Tavares, Irlaneide da Silva
    Melo, Luiza Dantas
    Doria, Fabiana de Santana
    Sobral Sousa, Antonio Carlos
    Francisco Pinto, Ibraim Masciarelli
    ARQUIVOS BRASILEIROS DE CARDIOLOGIA, 2015, 104 (05) : 409 - 416
  • [9] THE COMPOSITION OF BONE-MARROW FOR A DUAL-ENERGY QUANTITATIVE COMPUTED-TOMOGRAPHY TECHNIQUE - A CADAVER AND COMPUTER-SIMULATION STUDY
    GOODSITT, MM
    HOOVER, P
    VELDEE, MS
    HSUEH, SL
    INVESTIGATIVE RADIOLOGY, 1994, 29 (07) : 695 - 704
  • [10] Computation of Calcium Score With Dual-Energy Computed Tomography: A Phantom Study
    Kumar, Vidhya
    Min, James K.
    He, Xin
    Raman, Subha V.