Vibration control of structure by top base isolated storey as tuned mass damper

被引:0
作者
Manchalwar A. [1 ]
Bakre S.V. [2 ]
机构
[1] Gokaraju Rangaraju Institute of Engineering and Technology, Hyderabad
[2] Visvesvaraya National Institute of Technology, Nagpur
来源
Intl. J. Dyn. Cont. | 2020年 / 3卷 / 963-972期
关键词
Base isolation; Lead rubber bearing; Time history analysis; Tuned mass damper; Vibration control;
D O I
10.1007/s40435-020-00614-1
中图分类号
学科分类号
摘要
Presently, earthquake-resistant design provisions are based on the assumption of inelastic behaviour of structures in major earthquake occurrences. It is generally possible to achieve ductile behaviour with significant damage in steel and reinforced concrete structures. The passive control system is generally used to protect a building from the damaging effect of an earthquake. In the present work, the study of building with Base Isolated top floor as a tuned mass damper (TMD) is considered. The top storey is used as TMD for this purpose, the isolation system is provided at the base of the top storey of a building. This TMD being made up of concrete has the same damping ratio as that of the main building. Effectiveness of Base Isolated TMD is ascertained by comparing the results of the considered building of analysis by using Time History Analysis. By comparing the results, it is observed that Base Isolated TMD is quite effective as compared to building without TMD. © 2020, Springer-Verlag GmbH Germany, part of Springer Nature.
引用
收藏
页码:963 / 972
页数:9
相关论文
共 16 条
[1]  
Housner G.W., Bergman L.A., Caughey T.K., Chassiakos A.G., Claus R.O., Masri S.F., Skelton R.E., Soong T.T., Spencer B.F., Yao J.T.P., Structural control: past, present and future, J Eng Mech, 123, 9, pp. 897-971, (1997)
[2]  
Palazzo B., Petti L., Combined control strategy: base isolation and tuned mass damping, ISET J Earthq Technol, 36, 2-4, pp. 121-137, (1999)
[3]  
Jangid R.S., Bakre S.V., Optimum parameters of tuned mass damper for damped main system, Struct Control Health Monit, 14, 3, pp. 448-470, (2007)
[4]  
Taniguchi T., Kiureghian A.D., Melkumyan M., Effect of tuned mass damper on displacement demand of base-isolated structures, Eng Struct, 30, 12, pp. 3478-3488, (2008)
[5]  
Thakur V.M., Pachpor P.D., Seismic analysis of multistoried building with TMD, Int J Eng Res Appl, 2, 1, pp. 319-326, (2012)
[6]  
Matta E., Effectiveness of tuned mass dampers against ground motion pulses, J Struct Eng, 139, 2, pp. 188-198, (2013)
[7]  
Shariatmadara H., Razavi H.M., Seismic control response of structures using an ATMD with fuzzy logic controller and PSO method, Struct Eng Mech, 51, 4, pp. 547-564, (2014)
[8]  
Sadek F., Mohraz B., Taylor A.W., Chung R.M., A method of estimating the parameters of tuned mass dampers for seismic application, Earthq Eng Struct Dyn, 26, pp. 617-635, (1997)
[9]  
Su L., Ahmadi G., Tadjbakhsh I.G., Performance of sliding resilient-friction base isolation system, J Struct Eng, 117, 1, pp. 165-181, (1991)
[10]  
Naeim F., Kelly J.M., Design of seismic isolated structures: from theory and practice, (1999)