Procedures were developed for determining ionol by voltammetry and by coulometric titration with electrogenerated chlorine using the amperometric indication of the titration end point. Possible mechanisms of ionol oxidation with electrogenerated chlorine and its electrochemical oxidation at a glassy carbon and a gold electrode were discussed. Procedures were developed for determining ionol in mineral oil in analytical ranges from 1.0 × 10–4 to 1.0 × 10–2 M (RSD = 9%) and from 3.0 × 10–5 to 4.0 × 10–3 M (RSD = 9%) using a glassy carbon and a gold electrode, respectively. The detection limits for ionol at the glassy carbon and gold electrode were 2.8 × 10–4 and 1.0 × 10–5 M, respectively. The detection limit in coulometric titration was 20 μg/mL.
引用
收藏
页码:248 / 252
页数:4
相关论文
共 50 条
  • [21] Determination of Barium by Stripping Voltammetry
    S. V. Kovaleva
    V. P. Gladyshev
    N. V. Chikineva
    Journal of Analytical Chemistry, 2001, 56 : 449 - 452
  • [22] Determination of iodide ions at poly(3-methylthiophene)-modified electrode by differential pulse stripping voltammetry
    S. Titretir
    G. Erdoğdu
    A. E. Karagözler
    Journal of Analytical Chemistry, 2006, 61 : 592 - 595
  • [23] Precise coulometric titration of precious metals .3. Determination of gold(III) with electrogenerated chlorocuprous ion in KCl-Cu-EDTA buffer medium
    Dong, SA
    Yang, XY
    TALANTA, 1996, 43 (07) : 1109 - 1115
  • [24] Electrochemical Preconcentration of Iodide and Its Determination by Cathodic Stripping Voltammetry
    N. K. Zaitsev
    E. A. Osipova
    D. M. Fedulov
    A. G. Dedov
    Journal of Analytical Chemistry, 2004, 59 : 474 - 480
  • [25] Ceramic composite electrode for the determination of selenium(IV) by stripping voltammetry
    N. Yu. Stozhko
    E. I. Morosanova
    L. I. Kolyadina
    S. V. Fomina
    Journal of Analytical Chemistry, 2006, 61 : 158 - 165
  • [26] Galvanostatic coulometric determination of salicylic acid and some of its derivatives using electrogenerated halogens
    Abdullin, IF
    Chernysheva, NN
    Budnikov, GK
    JOURNAL OF ANALYTICAL CHEMISTRY, 2002, 57 (08) : 721 - 723
  • [27] Galvanostatic Coulometric Determination of Salicylic Acid and Some of Its Derivatives Using Electrogenerated Halogens
    I. F. Abdullin
    N. N. Chernysheva
    G. K. Budnikov
    Journal of Analytical Chemistry, 2002, 57 : 721 - 723
  • [28] THIOUREA DETERMINATION FOR THE PRECIOUS METALS LEACHING PROCESS BY IODATE TITRATION
    Calla-Choque, D.
    Nava-Alonso, F.
    REVISTA MEXICANA DE INGENIERIA QUIMICA, 2020, 19 (01): : 275 - 284
  • [29] Coulometric Determination of Purine Alkaloid Series with Electrogenerated Chlorine
    N. N. Chernysheva
    I. F. Abdullin
    G. K. Budnikov
    Journal of Analytical Chemistry, 2001, 56 : 663 - 665
  • [30] Coulometric determination of purine alkaloid series with electrogenerated chlorine
    Chernysheva, NN
    Abdullin, IF
    Budnikov, GK
    JOURNAL OF ANALYTICAL CHEMISTRY, 2001, 56 (07) : 663 - 665