Determination of Ionol by Voltammetry and Coulometric Titration

被引:0
|
作者
I. F. Abdullin
E. N. Turova
Yu. V. Parshakova
G. K. Budnikov
E. L. Gogolashvili
机构
[1] Kazan State University,Department of Chemistry
[2] Energoprogress Research Center,undefined
来源
Journal of Analytical Chemistry | 2002年 / 57卷
关键词
Oxidation; Gold; Analytical Chemistry; Titration; Detection Limit;
D O I
暂无
中图分类号
学科分类号
摘要
Procedures were developed for determining ionol by voltammetry and by coulometric titration with electrogenerated chlorine using the amperometric indication of the titration end point. Possible mechanisms of ionol oxidation with electrogenerated chlorine and its electrochemical oxidation at a glassy carbon and a gold electrode were discussed. Procedures were developed for determining ionol in mineral oil in analytical ranges from 1.0 × 10–4 to 1.0 × 10–2 M (RSD = 9%) and from 3.0 × 10–5 to 4.0 × 10–3 M (RSD = 9%) using a glassy carbon and a gold electrode, respectively. The detection limits for ionol at the glassy carbon and gold electrode were 2.8 × 10–4 and 1.0 × 10–5 M, respectively. The detection limit in coulometric titration was 20 μg/mL.
引用
收藏
页码:248 / 252
页数:4
相关论文
共 50 条
  • [1] Determination of Uric Acid by Voltammetry and Coulometric Titration
    I. F. Abdullin
    Yu. N. Bakanina
    E. N. Turova
    G. K. Budnikov
    Journal of Analytical Chemistry, 2001, 56 : 453 - 456
  • [2] Determination of Some Catecholamines by Coulometric Titration and Cyclic Voltammetry
    G. K. Ziyatdinova
    G. K. Budnikov
    Journal of Analytical Chemistry, 2005, 60 : 673 - 677
  • [3] Determination of some catecholamines by coulometric titration and cyclic voltammetry
    Ziyatdinova, GK
    Budnikov, GK
    JOURNAL OF ANALYTICAL CHEMISTRY, 2005, 60 (07) : 673 - 677
  • [4] Coulometric titration of substituted LixLa(2−x)/3 TiO3
    M. Klingler
    W. F. Chu
    W. Weppner
    Ionics, 1997, 3 : 289 - 291
  • [5] Coulometric Determination of Iridium in Fluoride and Chloride Solutions
    N. A. Ezerskaya
    I. N. Kiseleva
    Journal of Analytical Chemistry, 2001, 56 : 855 - 858
  • [6] Coulometric determination of iridium in fluoride and chloride solutions
    Ezerskaya, NA
    Kiseleva, IN
    JOURNAL OF ANALYTICAL CHEMISTRY, 2001, 56 (09) : 855 - 858
  • [7] Coulometric Titration of Substituted LixLa(2-x)/3TiO3
    Klingler, M.
    Chu, W. F.
    Weppner, W.
    IONICS, 1997, 3 (3-4) : 289 - 291
  • [8] Simple and Automated Coulometric Titration of Acid Using Nonisolated Electrodes
    Kuntzleman, Thomas S.
    Kenney, Joshua B.
    Hasbrouck, Scott
    Collins, Michael J.
    Amend, John R.
    JOURNAL OF CHEMICAL EDUCATION, 2011, 88 (11) : 1565 - 1568
  • [9] Determination of Ochratoxin at Nanocomposite Modified Glassy Carbon Electrode Combine with FFT Coulometric Admittance Voltammetry and Flow Injection Analysis
    Norouzi, Parviz
    Alahdadi, Iraj
    Shahtaheri, Seyed Jamaleddin
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2015, 10 (04): : 3400 - 3413
  • [10] Difficulties with the Determination of Mercury in Foodstuffs by Stripping Voltammetry
    V. N. Batalova
    E. A. Zakharova
    G. B. Slepchenko
    M. V. Malygina
    Journal of Analytical Chemistry, 2004, 59 : 468 - 473