Contrast-enhanced ultrasound: a comprehensive review of safety in children

被引:0
作者
Aikaterini Ntoulia
Sudha A. Anupindi
Susan J. Back
Ryne A. Didier
Misun Hwang
Ann M. Johnson
M. Beth McCarville
Frederica Papadopoulou
Maciej Piskunowicz
Maria E. Sellars
Kassa Darge
机构
[1] Children’s Hospital of Philadelphia,Department of Radiology
[2] University of Pennsylvania,Perelman School of Medicine
[3] St. Jude Children’s Research Hospital,Department of Diagnostic Imaging
[4] Pediatric Ultrasound Center,Department of Radiology
[5] Medical University of Gdansk,Department of Radiology
[6] King’s College Hospital,undefined
来源
Pediatric Radiology | 2021年 / 51卷
关键词
Adverse events; Adverse reactions; Children; Contrast-enhanced ultrasound; Intracavitary; Intravenous; Intravesical; Safety; Ultrasound; Ultrasound contrast agents;
D O I
暂无
中图分类号
学科分类号
摘要
Contrast-enhanced ultrasound (CEUS) has been increasingly used in pediatric radiology practice worldwide. For nearly two decades, CEUS applications have been performed with the off-label use of gas-containing second-generation ultrasound contrast agents (UCAs). Since 2016, the United States Food and Drug Administration (FDA) has approved the UCA Lumason for three pediatric indications: the evaluation of focal liver lesions and echocardiography via intravenous administration and the assessment of vesicoureteral reflux via intravesical application (contrast-enhanced voiding urosonography, ceVUS). Prior to the FDA approval of Lumason, numerous studies with the use of second-generation UCAs had been conducted in adults and children. Comprehensive protocols for clinical safety evaluations have demonstrated the highly favorable safety profile of UCA for intravenous, intravesical and other intracavitary uses. The safety data on CEUS continue to accumulate as this imaging modality is increasingly utilized in clinical settings worldwide. As of August 2021, 57 pediatric-only original research studies encompassing a total of 4,518 children with 4,906 intravenous CEUS examinations had been published. As in adults, there were a few adverse events; the majority of these were non-serious, although very rarely serious anaphylactic reactions were reported. In the published pediatric-only intravenous CEUS studies included in our analysis, the overall incidence rate of serious adverse events was 0.22% (10/4,518) of children and 0.20% (10/4,906) of all CEUS examinations. Non-serious adverse events from the intravenous CEUS were observed in 1.20% (54/4,518) of children and 1.10% (54/4,906) of CEUS examinations. During the same time period, 31 studies with the intravesical use of UCA were conducted in 12,362 children. A few non-serious adverse events were encountered (0.31%; 38/12,362), but these were most likely attributable to the bladder catheterization rather than the UCA. Other developing clinical applications of UCA in children, including intracavitary and intralymphatic, are ongoing. To date, no serious adverse events have been reported with these applications. This article reviews the existing pediatric CEUS literature and provides an overview of safety-related information reported from UCA uses in children.
引用
收藏
页码:2161 / 2180
页数:19
相关论文
共 327 条
[1]  
Piscaglia F(2006)The safety of Sonovue in abdominal applications: retrospective analysis of 23,188 investigations Ultrasound Med Biol 32 1369-1375
[2]  
Bolondi L(2017)Safety of sulfur hexafluoride microbubbles in sonography of abdominal and superficial organs: retrospective analysis of 30,222 cases J Ultrasound Med 36 531-538
[3]  
Tang C(2019)Adverse reactions after the use of SonoVue contrast agent: characteristics and nursing care experience Medicine 98 e17745-277
[4]  
Fang K(2021)European Federation of Societies for ultrasound in medicine and biology (EFSUMB): an update on the pediatric CEUS registry on behalf of the "EFSUMB pediatric CEUS registry working group" Ultrasound in Medicine and Biology 42 270-1480
[5]  
Guo Y(2012)Application of a second-generation US contrast agent in infants and children — a European questionnaire-based survey Pediatr Radiol 42 1471-452
[6]  
Hu C(2019)The safety and effectiveness of intravenous contrast-enhanced sonography in Chinese children — a single center and prospective study in China Front Pharmacol 10 1447-1399
[7]  
Feng Y(2017)Retrospective analysis of the safety and cost implications of pediatric contrast-enhanced ultrasound at a single center AJR Am J Roentgenol 208 446-1099
[8]  
Huang P(2017)Contrast-enhanced ultrasound using sulfur hexafluoride is safe in the pediatric setting Acta Radiol 58 1395-1001
[9]  
Dietrich CF(2015)Safety of intravenous application of second-generation ultrasound contrast agent in children: prospective analysis Ultrasound Med Biol 41 1095-626
[10]  
Augustiniene R(2018)Contrast-enhanced ultrasound for identifying circulatory complications after liver transplants in children Pediatr Transplant 23 e13327-155