Selective improvement of peptides imaging on tissue by supercritical fluid wash of lipids for matrix-assisted laser desorption/ionization mass spectrometry

被引:0
作者
Shoko Matsushita
Noritaka Masaki
Kohei Sato
Takahiro Hayasaka
Eiji Sugiyama
Shu-Ping Hui
Hitoshi Chiba
Nobuyuki Mase
Mitsutoshi Setou
机构
[1] Hamamatsu University School of Medicine,Department of Cellular and Molecular Anatomy
[2] Hamamatsu University School of Medicine,International Mass Imaging Center
[3] Research Fellow of Japan Society for the Promotion of Science,Department of Applied Chemistry and Biochemical Engineering, Faculty of Engineering
[4] Kojimachi Business Center Building,Health Innovation and Technology Center, Faculty of Health Sciences
[5] Shizuoka University,Preeminent Medical Photonics Education and Research Center
[6] Hokkaido University,Department of Anatomy
[7] Hamamatsu University School of Medicine,Division of Neural Systematics
[8] The University of Hong Kong,undefined
[9] Riken Center for Molecular Imaging Science,undefined
[10] National Institute for Physiological Sciences,undefined
来源
Analytical and Bioanalytical Chemistry | 2017年 / 409卷
关键词
Imaging mass spectrometry; Supercritical fluid of CO; Peptides; Pretreatment; Matrix-assisted laser desorption/ionization;
D O I
暂无
中图分类号
学科分类号
摘要
There is a high analytical demand for improving the detection sensitivity for various peptides in matrix-assisted laser desorption/ionization imaging mass spectrometry (MALDI-IMS) because exhaustive distribution analyses of various peptides could help to reveal the function of peptides in vivo. To improve the sensitivity of peptide detection, we used supercritical fluid of CO2 (scCO2) as washing solvent for a pretreatment to remove lipids. We evaluated whether our wash method using scCO2 with an entrainer improved the detection of peptides and suppressed lipid detection in MALDI-IMS. Our analysis revealed that the signal intensities of peptides such as m/z 3339.8, 3530.9, 4233.3, 4936.7, and 4963.7 were increased in scCO2-washed samples. The greatest improvement in the signal-to-noise ratio (S/N) was found at m/z 4963.7, which was identified as thymosin β4, with the S/N reaching almost 190-fold higher than the control. Additionally, all of the improved signals were associated with the morphologic structure. Our method allows us to analyze the distribution of molecules, especially in the region of m/z 3000–5200. For these improvements, the polarity difference between scCO2 and the matrix solution used was considered as a key. A wider variety of molecules can be analyzed in the future due to this improvement of the detection sensitivity by optimizing the polarity of scCO2 with various entrainers.
引用
收藏
页码:1475 / 1480
页数:5
相关论文
共 50 条
  • [41] Deuterated Matrix-Assisted Laser Desorption Ionization Matrix Uncovers Masked Mass Spectrometry Imaging Signals of Small Molecules
    Shariatgorji, Mohammadreza
    Nilsson, Anna
    Goodwin, Richard J. A.
    Svenningsson, Per
    Schintu, Nicoletta
    Banka, Zoltan
    Kladni, Laszlo
    Hasko, Tibor
    Szabo, Andras
    Andren, Per E.
    ANALYTICAL CHEMISTRY, 2012, 84 (16) : 7152 - 7157
  • [42] Applications of Matrix-Assisted Laser Desorption Ionization In-Source Decay Mass Spectrometry
    Ju, Yue
    ADVANCEMENTS OF MASS SPECTROMETRY IN BIOMEDICAL RESEARCH, 2ND EDITION, 2019, 1140 : 45 - 54
  • [43] Fundamentals of matrix-assisted laser desorption/ionization mass spectrometry with pulsed infrared lasers
    Dreisewerd, K
    Berkenkamp, S
    Leisner, A
    Rohlfing, A
    Menzel, C
    INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2003, 226 (01) : 189 - 209
  • [44] Infrared matrix-assisted laser desorption/ionization quadrupole ion trap mass spectrometry
    Lippa, T
    Taranenko, NI
    Prasad, CR
    Doroshenko, VM
    EUROPEAN JOURNAL OF MASS SPECTROMETRY, 2002, 8 (03) : 263 - 271
  • [45] Continuous flow infrared matrix-assisted laser desorption electrospray ionization mass spectrometry
    Huang, Fan
    Murray, Kermit K.
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2010, 24 (19) : 2799 - 2804
  • [46] GUMBOS matrices of variable hydrophobicity for matrix-assisted laser desorption/ionization mass spectrometry
    Al Ghafly, Hashim
    Siraj, Noureen
    Das, Susmita
    Regmi, Bishnu P.
    Magut, Paul K. S.
    Galpothdeniya, Waduge Indika S.
    Murray, Kermit K.
    Warner, Isiah M.
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2014, 28 (21) : 2307 - 2314
  • [47] Silver nanoparticles as matrix for laser desorption/ionization mass spectrometry of peptides
    Lin Hua
    Jianrong Chen
    Liya Ge
    Swee Ngin Tan
    Journal of Nanoparticle Research, 2007, 9 : 1133 - 1138
  • [48] Effective detection of peptides containing cysteine sulfonic acid using matrix-assisted laser desorption/ionization and laser desorption/ionization on porous silicon mass spectrometry
    Kinumi, T
    Shimomae, Y
    Arakawa, R
    Tatsu, Y
    Shigeri, Y
    Yumoto, N
    Niki, E
    JOURNAL OF MASS SPECTROMETRY, 2006, 41 (01): : 103 - 112
  • [49] Towards monitoring of protein purification by matrix-assisted laser desorption ionization mass spectrometry
    Jensen, C
    Haebel, S
    Andersen, SO
    Roepstorff, P
    INTERNATIONAL JOURNAL OF MASS SPECTROMETRY AND ION PROCESSES, 1997, 160 (1-3): : 339 - 356
  • [50] Matrix-assisted laser desorption/ionization mass spectrometry imaging as a new tool for molecular histopathology in epilepsy surgery
    Cagnoli, Cinzia
    De Santis, Dalia
    Caccia, Claudio
    Bongarzone, Italia
    Capitoli, Giulia
    Rossini, Laura
    Rizzi, Michele
    Deleo, Francesco
    Tassi, Laura
    de Curtis, Marco
    Garbelli, Rita
    EPILEPSIA, 2024, 65 (12) : 3631 - 3643