Selective improvement of peptides imaging on tissue by supercritical fluid wash of lipids for matrix-assisted laser desorption/ionization mass spectrometry

被引:0
作者
Shoko Matsushita
Noritaka Masaki
Kohei Sato
Takahiro Hayasaka
Eiji Sugiyama
Shu-Ping Hui
Hitoshi Chiba
Nobuyuki Mase
Mitsutoshi Setou
机构
[1] Hamamatsu University School of Medicine,Department of Cellular and Molecular Anatomy
[2] Hamamatsu University School of Medicine,International Mass Imaging Center
[3] Research Fellow of Japan Society for the Promotion of Science,Department of Applied Chemistry and Biochemical Engineering, Faculty of Engineering
[4] Kojimachi Business Center Building,Health Innovation and Technology Center, Faculty of Health Sciences
[5] Shizuoka University,Preeminent Medical Photonics Education and Research Center
[6] Hokkaido University,Department of Anatomy
[7] Hamamatsu University School of Medicine,Division of Neural Systematics
[8] The University of Hong Kong,undefined
[9] Riken Center for Molecular Imaging Science,undefined
[10] National Institute for Physiological Sciences,undefined
来源
Analytical and Bioanalytical Chemistry | 2017年 / 409卷
关键词
Imaging mass spectrometry; Supercritical fluid of CO; Peptides; Pretreatment; Matrix-assisted laser desorption/ionization;
D O I
暂无
中图分类号
学科分类号
摘要
There is a high analytical demand for improving the detection sensitivity for various peptides in matrix-assisted laser desorption/ionization imaging mass spectrometry (MALDI-IMS) because exhaustive distribution analyses of various peptides could help to reveal the function of peptides in vivo. To improve the sensitivity of peptide detection, we used supercritical fluid of CO2 (scCO2) as washing solvent for a pretreatment to remove lipids. We evaluated whether our wash method using scCO2 with an entrainer improved the detection of peptides and suppressed lipid detection in MALDI-IMS. Our analysis revealed that the signal intensities of peptides such as m/z 3339.8, 3530.9, 4233.3, 4936.7, and 4963.7 were increased in scCO2-washed samples. The greatest improvement in the signal-to-noise ratio (S/N) was found at m/z 4963.7, which was identified as thymosin β4, with the S/N reaching almost 190-fold higher than the control. Additionally, all of the improved signals were associated with the morphologic structure. Our method allows us to analyze the distribution of molecules, especially in the region of m/z 3000–5200. For these improvements, the polarity difference between scCO2 and the matrix solution used was considered as a key. A wider variety of molecules can be analyzed in the future due to this improvement of the detection sensitivity by optimizing the polarity of scCO2 with various entrainers.
引用
收藏
页码:1475 / 1480
页数:5
相关论文
共 50 条
  • [1] Selective improvement of peptides imaging on tissue by supercritical fluid wash of lipids for matrix-assisted laser desorption/ionization mass spectrometry
    Matsushita, Shoko
    Masaki, Noritaka
    Sato, Kohei
    Hayasaka, Takahiro
    Sugiyama, Eiji
    Hui, Shu-Ping
    Chiba, Hitoshi
    Mase, Nobuyuki
    Setou, Mitsutoshi
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2017, 409 (06) : 1475 - 1480
  • [2] Matrix-Assisted Laser Desorption/Ionization Imaging Mass Spectrometry
    Zaima, Nobuhiro
    Hayasaka, Takahiro
    Goto-Inoue, Naoko
    Setou, Mitsutoshi
    INTERNATIONAL JOURNAL OF MOLECULAR SCIENCES, 2010, 11 (12) : 5041 - 5056
  • [3] Matrix-Assisted Laser Desorption/Ionization Imaging Mass Spectrometry for the Investigation of Proteins and Peptides
    Burnum, Kristin E.
    Frappier, Sara L.
    Caprioli, Richard M.
    ANNUAL REVIEW OF ANALYTICAL CHEMISTRY, 2008, 1 : 689 - 705
  • [4] Matrix-assisted laser desorption ionization imaging mass spectrometry in lipidomics
    Fernandez, J. A.
    Ochoa, B.
    Fresnedo, O.
    Giralt, M. T.
    Rodriguez-Puertas, R.
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2011, 401 (01) : 29 - 51
  • [5] Matrix-assisted laser desorption ionization imaging mass spectrometry in lipidomics
    J. A. Fernández
    B. Ochoa
    O. Fresnedo
    M. T. Giralt
    R. Rodríguez-Puertas
    Analytical and Bioanalytical Chemistry, 2011, 401 : 29 - 51
  • [6] Effect of solvent on ionization efficiency in matrix-assisted laser desorption/ionization mass spectrometry of peptides
    Hazama, Hisanao
    Furukawa, Satoshi
    Awazu, Kunio
    CHEMICAL PHYSICS, 2013, 419 : 196 - 199
  • [7] Selective Analysis of Lipids by Thin-Layer Chromatography Blot Matrix-Assisted Laser Desorption/Ionization Imaging Mass Spectrometry
    Zaima, Nobuhiro
    Goto-Inoue, Naoko
    Adachi, Kohsuke
    Setou, Mitsutoshi
    JOURNAL OF OLEO SCIENCE, 2011, 60 (02) : 93 - 98
  • [8] Review of Matrix-Assisted Laser Desorption Ionization-Imaging Mass Spectrometry for Lipid Biochemical Histopathology
    Yalcin, Emine B.
    de la Monte, Suzanne M.
    JOURNAL OF HISTOCHEMISTRY & CYTOCHEMISTRY, 2015, 63 (10) : 762 - 771
  • [9] Considerations for quantification of lipids in nerve tissue using matrix-assisted laser desorption/ionization mass spectrometric imaging
    Landgraf, Rachelle R.
    Garrett, Timothy J.
    Conaway, Maria C. Prieto
    Calcutt, Nigel A.
    Stacpoole, Peter W.
    Yost, Richard A.
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2011, 25 (20) : 3178 - 3184
  • [10] Systematic assessment of surfactants for matrix-assisted laser desorption/ionization mass spectrometry imaging
    Banstola, Bijay
    Grodner, Eulalie T.
    Cao, Fan
    Donnarumma, Fabrizio
    Murray, Kermit K.
    ANALYTICA CHIMICA ACTA, 2017, 963 : 76 - 82