Silicone-selective multishot echo-planar imaging for rapid MRI survey of breast implants

被引:0
作者
Yasuo Amano
Ritsu Aoki
Shinichiro Kumita
Tatsuo Kumazaki
机构
[1] Nippon Medical School,Department of Radiology
[2] Nippon Medical School,Department of Plastic Surgery
来源
European Radiology | 2007年 / 17卷
关键词
Magnetic resonance; Breast; Silicone; Multishot echo-planer imaging;
D O I
暂无
中图分类号
学科分类号
摘要
The purpose of this study was to assess the usefulness of silicone-selective multishot echo-planar imaging (EPI) for the rapid magnetic resonance imaging (MRI) survey of breast implants. Twenty patients with bilateral breast implants underwent MRI. The use of inversion recovery and magnetization transfer pulses led to silicone-selective images. The rapid MRI survey required only 43 s, which accurately distinguished between silicone and non-silicone materials in the implants, and therefore induced the final MRI sequences appropriate for the detailed characterization of the implants. In 5 of the 20 patients, the rapid MRI survey showed implanted materials that were not indicated from clinical information. This silicone-selective multishot EPI allows a rapid survey of breast implants, which is useful to avoid unnecessary sequences in these patients.
引用
收藏
页码:1875 / 1878
页数:3
相关论文
共 49 条
[1]  
Robinson OG(1995)Analysis of explanted silicone implants: a report of 300 patients Ann Plast Surg 34 1-7
[2]  
Bradley EL(1994)Risk of connective-tissue diseases and other disorders after breast implantation N Engl J Med 330 1697-1702
[3]  
Wilson DS(1998)MR imaging of the augmented breast Eur Radiol 8 371-376
[4]  
Gabriel SE(1997)Rupture of silicone-gel breast implants: causes, sequelae, and diagnosis Lancet 350 1531-1537
[5]  
O’Fallon WM(2001)Silicone gel breast implant rupture, extracapsular silicone, and health status in a population of women J Rheumatol 28 996-1003
[6]  
Kurland LT(1994)Diagnosis of breast implant rupture: imaging findings and relative efficacies of imaging techniques AJR Am J Roentgenol 163 57-60
[7]  
Beard CM(1999)Silicone breast implant rupture: pitfalls of magnetic resonance imaging and relative efficacies of magnetic resonance, mammography, and ultrasound Plast Reconstr Surg 104 2054-2061
[8]  
Woods JE(1994)MR detection of leakage from silicone breast implants: value of a silicone-selective pulse sequence AJR Am J Roentgenol 163 51-56
[9]  
Melton LJ(1996)Complex radial folds versus subtle signs of intracapsular rupture of breast implants: MR findings with surgical correlation AJR Am J Roentgenol 166 1421-1427
[10]  
Huch RA(1993)Ultrafast interleaved gradient-echo-planar imaging on a standard scanner Magn Reson Med 30 609-616