Factors Affecting Accuracy of Ventricular Volume and Ejection Fraction Measured by Gated Tl-201 Myocardial Perfusion Single Photon Emission Computed Tomography

被引:0
|
作者
Moonsun Pai
You-Jung Yang
Ki Chun Im
Il Ki Hong
Sung Cheol Yun
Duk-Hyun Kang
Jae-Kwan Song
Dae Hyuk Moon
机构
[1] University of Ulsan College of Medicine,Department of Nuclear Medicine
[2] Ewha Womans University Mokdong Hospital,Division of Nuclear Medicine, Department of Radiology
[3] Asan Medical Center,Department of Nuclear Medicine
[4] Asan Medical Center,Division of Epidemiology and Biostatistics
[5] University of Ulsan College of Medicine,Division of Cardiology, Asan Medical Center
来源
The International Journal of Cardiovascular Imaging | 2006年 / 22卷
关键词
Left ventricular function; Left ventricular ejection fraction; Single photon emission-computed tomography; Thallium-201;
D O I
暂无
中图分类号
学科分类号
摘要
The electrocardiogram-gated single photon emission computed tomography (SPECT) measurement of left ventricular end-diastolic volume, end-systolic volume and ejection fraction may contain substantial errors. We evaluated whether patient-related factors affect the accuracy of left ventricular volume and ejection fraction measured by gated Tl-201 SPECT. A total of 518 patients without perfusion defects on Tl-201 SPECT or coronary artery disease were studied. Left ventricular volume and ejection fraction were measured from echocardiography and adenosine stress/redistribution gated Tl-201 SPECT using commercially available software packages (QGS and 4D-MSPECT). We identified factors affecting the accuracy of gated SPECT via multiple linear regression analysis of the differences between echocardiography and gated SPECT. Gated SPECT analyzed with QGS underestimated end-diastolic and end-systolic volume, and overestimated ejection fraction, but 4D-MSPECT overestimated all those values (P<0.001). Independent variables associated with increasing the difference in end-diastolic volume between echocardiography and gated SPECT were decreasing left ventricular end-diastolic wall thickness, decreasing body surface area, female sex and increasing end-diastolic volume (P<0.001). Those for end-systolic volume were decreasing left ventricular end-systolic wall thickness, female sex, and decreasing end-systolic volume (P<0.001). Increasing end-systolic wall thickness, male sex and decreasing age were independent determinants associated with an increased difference in ejection fraction (P<0.001). Adenosine stress SPECT showed significantly higher end-diastolic and end-systolic volume values and a lower ejection fraction than did redistribution SPECT (P<0.001). Patient-related factors affect the accuracy of left ventricular volume and ejection fraction measured by gated Tl-201 SPECT. Modification of gated SPECT measurements by taking account of these factors would lead to reduce systemic errors.
引用
收藏
页码:671 / 681
页数:10
相关论文
共 50 条
  • [21] Diagnostic accuracy of myocardial perfusion imaging with single photon emission computed tomography and positron emission tomography: a comparison with coronary angiography
    Husmann, Lars
    Wiegand, Mischa
    Valenta, Ines
    Gaemperli, Oliver
    Schepis, Tiziano
    Siegrist, Patrick T.
    Namdar, Mehdi
    Wyss, Christophe A.
    Alkadhi, Hatem
    Kaufmann, Philipp A.
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2008, 24 (05) : 511 - 518
  • [22] Diagnostic accuracy of myocardial perfusion imaging with single photon emission computed tomography and positron emission tomography: a comparison with coronary angiography
    Lars Husmann
    Mischa Wiegand
    Ines Valenta
    Oliver Gaemperli
    Tiziano Schepis
    Patrick T. Siegrist
    Mehdi Namdar
    Christophe A. Wyss
    Hatem Alkadhi
    Philipp A. Kaufmann
    The International Journal of Cardiovascular Imaging, 2008, 24 : 511 - 518
  • [23] Single-Photon Emission Computed Tomography Myocardial Perfusion Imaging and the Risk of Sudden Cardiac Death in Patients With Coronary Disease and Left Ventricular Ejection Fraction &gt;35%
    Piccini, Jonathan P.
    Starr, Aijing Z.
    Horton, John R.
    Shaw, Linda K.
    Lee, Kerry L.
    Al-Khatib, Sana M.
    Iskandrian, Ami E.
    O'Connor, Christopher M.
    Borges-Neto, Salvador
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2010, 56 (03) : 206 - 214
  • [24] TIME-SEQUENTIAL SINGLE PHOTON-EMISSION COMPUTED-TOMOGRAPHY STUDIES IN BRAIN-TUMOR USING TL-201
    UEDA, T
    KAJI, Y
    WAKISAKA, S
    WATANABE, K
    HOSHI, H
    JINNOUCHI, S
    FUTAMI, S
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 1993, 20 (02): : 138 - 145
  • [25] Impact of Diabetes Mellitus on Left Ventricular Synchrony by Gated Single-Photon Emission Computed Tomography Myocardial Perfusion Imaging Phase Analysis
    Malek, Hadi
    Noveiry, Rezvaneh Saken
    Yaghoobi, Nahid
    Bakhshandeh, Hooman
    Bitarafan-Rajabi, Ahmad
    Hassanzadeh, Leila
    Hedayati, Raheleh
    IRANIAN HEART JOURNAL, 2023, 24 (01): : 54 - 61
  • [26] Thallium-201 gated single-photon emission tomography for the assessment of left ventricular ejection fraction and regional wall motion abnormalities in comparison with two-dimensional echocardiography
    Claudia Bacher-Stier
    Silvana Müller
    Othmar Pachinger
    Silvia Strolz
    Hermann Erler
    Roy Moncayo
    Martin Wenger
    Eveline Donnemiller
    Georg Riccabona
    European Journal of Nuclear Medicine, 1999, 26 : 1533 - 1540
  • [27] Comparison of contemporaneous left ventricular ejection fraction (LVEF) obtained from planar gated cardiac blood pool scans (GCBPS) and Tl-201 gated myocardial perfusion scans (MPS) using a novel solid state dedicated cardiac camera
    Kenneth S. K. Yap
    Martin Cherk
    Bruce Van Every
    Michael Bailey
    Michael J. Kelly
    Victor Kalff
    Journal of Nuclear Cardiology, 2013, 20 : 367 - 374
  • [28] Reducing the small-heart effect in pediatric gated myocardial perfusion single-photon emission computed tomography
    Yoneyama, Hiroto
    Nakajima, Kenichi
    Okuda, Koichi
    Matsuo, Shinro
    Onoguchi, Masahisa
    Kinuya, Seigo
    Edenbrandt, Lars
    JOURNAL OF NUCLEAR CARDIOLOGY, 2017, 24 (04) : 1378 - 1388
  • [29] Comparison of contemporaneous left ventricular ejection fraction (LVEF) obtained from planar gated cardiac blood pool scans (GCBPS) and Tl-201 gated myocardial perfusion scans (MPS) using a novel solid state dedicated cardiac camera
    Yap, Kenneth S. K.
    Cherk, Martin
    Van Every, Bruce
    Bailey, Michael
    Kelly, Michael J.
    Kalff, Victor
    JOURNAL OF NUCLEAR CARDIOLOGY, 2013, 20 (03) : 367 - 374
  • [30] Effect of tracer dose on left ventricular mechanical dyssynchrony indices by phase analysis of gated single photon emission computed tomography myocardial perfusion imaging
    AlJaroudi, Wael
    Jaber, Wael A.
    Cerqueira, Manuel D.
    JOURNAL OF NUCLEAR CARDIOLOGY, 2012, 19 (01) : 63 - 72