The microcalorimeter X-ray detector: A true paradigm shift in X-ray spectroscopy

被引:0
|
作者
T. Jach
J. N. Ullom
W. T. Elam
机构
[1] National Institute of Standards and Technology,
[2] National Institute of Standards and Technology,undefined
[3] Applied Physics Laboratory,undefined
[4] University of Washington,undefined
关键词
European Physical Journal Special Topic; Transition Edge Sensor; High Energy Resolution; Grating Spectrometer; Advance Light Source;
D O I
暂无
中图分类号
学科分类号
摘要
The microcalorimeter x-ray detector registers the heat deposited in an absorber from individual x-ray photons by means of a sensitive thermometer. It combines advantages of wavelength-dispersive and energy-dispersive detectors: relatively high energy resolution over a broad energy spectrum. Operating at very low temperatures reduces the noise, making the high energy resolution possible. The absorber can be tailored to any energy range, from soft x-rays to gamma rays. After many years of development, several designs have reached a level of performance and reliability that makes them competitive x-ray detectors for many kinds of experiment. We survey current microcalorimeter detectors using several different thermometers. Their applications already run from chemical analysis to plasma physics and x-ray astronomy. We describe two examples of how the microcalorimeter detector can enable novel determinations in x-ray physics.
引用
收藏
页码:237 / 242
页数:5
相关论文
共 50 条
  • [41] The X-ray microcalorimeter instruments on the Astro-E2 and constellation-X X-ray observatories
    Kelley, RL
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2004, 520 (1-3): : 364 - 367
  • [42] A NEW MICROCALORIMETER CONCEPT FOR PHOTON-COUNTING X-RAY SPECTROSCOPY
    SILVER, EH
    LABOV, SE
    GOULDING, F
    MADDEN, N
    LANDIS, D
    BEEMAN, J
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1989, 277 (2-3): : 657 - 663
  • [43] A multielectrode X-ray detector
    Barykov, IA
    Gott, YV
    Stepanenko, MM
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES, 2006, 49 (02) : 270 - 273
  • [44] A multielectrode X-ray detector
    I. A. Barykov
    Yu. V. Gott
    M. M. Stepanenko
    Instruments and Experimental Techniques, 2006, 49 : 270 - 273
  • [45] THE PHOTOMULTIPLIER X-RAY DETECTOR
    MARSHALL, FH
    COLTMAN, JW
    HUNTER, LP
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1947, 18 (07): : 504 - 513
  • [46] A spectrozonal X-ray detector
    Lelyukhin A.S.
    Kornev E.A.
    Biomedical Engineering, 2004, 38 (4) : 176 - 179
  • [47] THE PHOTOMULTIPLIER X-RAY DETECTOR
    MARSHALL, FH
    HUNTER, LP
    PHYSICAL REVIEW, 1946, 69 (1-2): : 48 - 48
  • [48] Silicon pixel detector for X-ray spectroscopy.
    Seller, P
    Gannon, WJF
    Holland, A
    Iles, G
    Lowe, B
    Prydderch, ML
    Thomas, SL
    Wade, R
    EUV, X-RAY, AND GAMMA-RAY INSTRUMENTATION FOR ASTRONOMY IX, 1998, 3445 : 584 - 592
  • [49] X-Ray Spectroscopy with a Room Temperature CdZnTe Detector
    Fritz, S. G.
    Shikhaliev, P. M.
    MEDICAL PHYSICS, 2010, 37 (06)
  • [50] Thin CdTe detector in diagnostic x-ray spectroscopy
    Miyajima, S
    MEDICAL PHYSICS, 2003, 30 (05) : 771 - 777