Critical parameters of nylon and other fibres for spalling protection of high strength concrete in fire

被引:0
作者
Young-Sun Heo
Jay G. Sanjayan
Cheon-Goo Han
Min-Cheol Han
机构
[1] Monash University,Department of Civil Engineering
[2] Swinburne University of Technology,Engineering and Industrial Sciences
[3] Cheongju University,Division of Architectural Engineering
来源
Materials and Structures | 2011年 / 44卷
关键词
High strength concrete; Fire; Spalling; Fibre; Nylon; Polypropylene;
D O I
暂无
中图分类号
学科分类号
摘要
This study investigated various types of fibre length, fibre diameter, fibre type and fibre content on the degree of spalling of concrete in fire. Four types of fibres, namely, polypropylene, polyvinyl alcohol, cellulose and nylon with various lengths and diameters were studied. Fibre contents ranged from 0.05 to 0.15% by volume of concrete. Fire tests were conducted according to the ISO 834 standard heating curve. Results showed that when comparing all the fibres under the same fibre content levels (% volume of concrete), the nylon fibre was the most effective in protecting concrete from spalling. This is because the diameter of the nylon fibres were significantly less than the other fibres, hence there were significantly more number of nylon fibres present for the same fibre content (% volume) in concrete. Analysis revealed, regardless of the amount of fibre, the type of fibre, diameter of and length of fibre, there is a strong relationship between the total number of fibres present per unit volume, length of fibres and the degree of spalling observed. Based on this relationship, the authors established a critical minimum for total number of fibres per unit volume for spalling protection in fire.
引用
收藏
页码:599 / 610
页数:11
相关论文
共 50 条
[21]   Fire Protection of Concrete Tunnel Linings with Waste Tyre Fibres [J].
Figueiredo, Fabio P. ;
Shah, Asif Hussain ;
Huang, Shan-Shan ;
Angelakopoulos, Harris ;
Pilakoutas, Kypros ;
Burgess, Ian .
PERFORMANCE OF MATERIALS AND STRUCTURES UNDER EXTREME CONDITIONS, 2017, 210 :472-478
[22]   Explosive Spalling of Concrete Columns with Steel and Polypropylene Fibres Subjected to Severe Fire [J].
Doherty, P. ;
Ali, F. ;
Nadjai, A. .
STRUCTURES IN FIRE: PROCEEDINGS OF THE 6TH INTERNATIONAL CONFERENCE, 2010, :165-172
[23]   Critical parameters for the compressive strength of high-strength concrete [J].
Hoang Thanh Nam Le ;
Poh, Leong Hien ;
Wang, Shasha ;
Zhang, Min-Hong .
CEMENT & CONCRETE COMPOSITES, 2017, 82 :202-216
[24]   Role of Polypropylene Fibres in Concrete Spalling Risk Mitigation in Fire and Test Methods of Fibres Effectiveness Evaluation [J].
Hager, Izabela ;
Mroz, Katarzyna .
MATERIALS, 2019, 12 (23)
[25]   Performance of Rubberized High Strength Concrete After Fire [J].
Liu, Feng ;
Chen, Guixuan ;
Li, Lijuan .
ADVANCES IN STRUCTURES, PTS 1-5, 2011, 163-167 :1403-1408
[26]   PERFORMANCE OF RUBBERIZED HIGH STRENGTH CONCRETE AFTER FIRE [J].
Li, Li-Juan ;
Xie, Wei-Feng ;
Chen, Zhi-Ze ;
Chen, Ying-Qin ;
Lu, Hui-Xiang ;
Wan, Rui-Hua .
PROCEEDINGS OF THE TENTH INTERNATIONAL SYMPOSIUM ON STRUCTURAL ENGINEERING FOR YOUNG EXPERTS, VOLS I AND II, 2008, :1992-1996
[27]   Critical Fiber Dimesions for Preventing Spalling of Ultra-high Performance Concrete at High Temperature [J].
Zhang, Dong ;
Tan, Kang Hai .
FIRE TECHNOLOGY, 2024, 60 (05) :3043-3058
[28]   Explosive spalling of normal strength concrete slabs subjected to severe fire [J].
Ali, Faris ;
Nadjai, Ali ;
Abu-Tair, Abid .
MATERIALS AND STRUCTURES, 2011, 44 (05) :943-956
[29]   Explosive spalling of normal strength concrete slabs subjected to severe fire [J].
Faris Ali ;
Ali Nadjai ;
Abid Abu-Tair .
Materials and Structures, 2011, 44 :943-956
[30]   An experimental evaluation to determine the required thickness of passive fire protection layer for high strength concrete tunnel segments [J].
Bezgin, Niyazi Ozgur .
CONSTRUCTION AND BUILDING MATERIALS, 2015, 95 :279-286