A microcantilever-based gas flow sensor for flow rate and direction detection

被引:0
|
作者
Rong-Hua Ma
Po-Cheng Chou
Yu-Hsiang Wang
Tzu-Han Hsueh
Lung-Ming Fu
Chia-Yen Lee
机构
[1] R.O.C. Military Academy,
[2] Shu-Te University,undefined
[3] Da-Yeh University,undefined
[4] National Pingtung University,undefined
来源
Microsystem Technologies | 2009年 / 15卷
关键词
Residual Stress; Cantilever Beam; Nitride Layer; Upward Direction; Flow Sensor;
D O I
暂无
中图分类号
学科分类号
摘要
Utilizing conventional micro-electro-mechanical systems techniques, this study fabricates and characterizes a novel micro gas flow sensor comprising four silicon nitride/silicon wafer cantilever beams arranged in a cross-form configuration. The residual stresses induced within the beams during their fabrication cause the tip of each beam to curve slightly in the upward direction. However, as air travels over the surface of the sensor, the upstream cantilevers are deflected in the downward direction, while the downstream cantilevers are deflected in the upward direction. The velocity of the air flow is then determined by measuring the corresponding change in resistance of the piezoresistors patterned on the upper surface of each cantilever beam. It is shown that by measuring the change in resistance of all four cantilever beams, the proposed sensor can detect not only the velocity of the air flow, but also its direction.
引用
收藏
页码:1201 / 1205
页数:4
相关论文
共 50 条
  • [31] Fabrication, calibration, and preliminary testing of microcantilever-based piezoresistive sensor for BioMEMS applications
    Rotake, Dinesh
    Darji, Anand
    Kale, Nitin
    IET NANOBIOTECHNOLOGY, 2020, 14 (05) : 357 - 368
  • [32] Fabrication and sensing behavior of ultrasensitive piezoelectric microcantilever-based precision mass sensor
    Shin, Sanghun
    Lee, Jaichan
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2006, 49 : S608 - S611
  • [33] A Micromachined Cantilever Based Flow Rate and Flow Direction Sensing Scheme
    Ashish
    Shanmuganantham, T.
    2014 INTERNATIONAL CONFERENCE ON COMMUNICATIONS AND SIGNAL PROCESSING (ICCSP), 2014,
  • [34] A smart flow sensor for flow direction measurement
    Lee, Chia-Yen
    Wang, Yu-Hsiang
    Hsueh, Tzu-Han
    Ma, Rong-Hua
    Fu, Lung-Ming
    Chou, Po-Cheng
    MULTI-FUNCTIONAL MATERIALS AND STRUCTURES, PTS 1 AND 2, 2008, 47-50 : 189 - +
  • [35] Rapid and Reliable Calibration of Laser Beam Deflection System for Microcantilever-Based Sensor Setups
    Mishra, Rohit
    Grange, Wilfried
    Hegner, Martin
    JOURNAL OF SENSORS, 2012, 2012
  • [36] Simple and sensitive method of microcantilever-based DNA detection using nanoparticles conjugates
    Cha, Byung Hak
    Lee, Sang-Myung
    Hwang, Kyo Seon
    Kim, Sang Kyung
    Lee, Yoon-Sik
    Ju, Byeong-Kwon
    Kim, Tae Song
    2008 3RD IEEE INTERNATIONAL CONFERENCE ON NANO/MICRO ENGINEERED AND MOLECULAR SYSTEMS, VOLS 1-3, 2008, : 160 - 160
  • [37] Highly sensitive microcantilever-based immunosensor for the detection of carbofuran in soil and vegetable samples
    Dai, Yingping
    Wang, Ting
    Hu, Xiaoya
    Liu, Shuzhao
    Zhang, Ming
    Wang, Chengyin
    FOOD CHEMISTRY, 2017, 229 : 432 - 438
  • [38] A Characterization of the Performance of Gas Sensor Based on Heater in Different Gas Flow Rate Environments
    Dong, Linxi
    Xu, Zhongren
    Xuan, Weipeng
    Yan, Haixia
    Liu, Chaoran
    Zhao, Wen-Sheng
    Wang, Gaofeng
    Teh, Kwok Siong
    IEEE TRANSACTIONS ON INDUSTRIAL INFORMATICS, 2020, 16 (10) : 6281 - 6290
  • [39] Design and Performance Analysis of a Microbridge and Microcantilever-Based MEMS Pressure Sensor for Glucose Monitoring
    Lakshmi, Guttikonda Sai
    Karumuri, Srinivasa Rao
    Kondavitee, Girija Sravani
    Lay-Ekuakille, Aime
    IEEE SENSORS JOURNAL, 2023, 23 (05) : 4589 - 4596
  • [40] Piezoresistive microcantilever-based DNA sensor for sensitive detection of pathogenic Vibrio cholerae O1 in food sample
    Khemthongcharoen, Numfon
    Wonglumsom, Wijit
    Suppat, Assawapong
    Jaruwongrungsee, Kata
    Tuantranont, Adisorn
    Promptmas, Chamras
    BIOSENSORS & BIOELECTRONICS, 2015, 63 : 347 - 353