Simultaneous detection of five biomarkers of lung cancer by electrochemical immunoassay

被引:1
|
作者
Jiao Shan
Zhanfang Ma
机构
[1] Capital Normal University,Department of Chemistry
来源
Microchimica Acta | 2016年 / 183卷
关键词
Polymerized dye; Gold composite; Polyaniline; Electrochemical immunoassay; Square wave voltammetry; Lung tumor;
D O I
暂无
中图分类号
学科分类号
摘要
Four kinds of redox species including three kinds of polymerized dye-gold composites and one kind of a polyaniline-gold composite were synthesized by a one-pot method at room temperature. Gold in these composites plays the roles of improving the conductivity and fixing the detection antibodies. The four composites together with hexacyanocobaltate were used as redox active species for simultaneous detection of five biomarkers of lung cancer including the carcinoembryonic antigen (CEA), neuron specific enolase (NSE), carbohydrate antigen 125 (CA125), cytokeratin 19 fragment antigen 21–1 (Cyfra21–1), and squamous cell carcinoma antigen (SCCA). The immunoassays display good linear relationship between the current response and the logarithm of the analyte. The analytical ranges extend from 1 to 150 ng⋅mL-1 for CEA, NSE and Cyfra21–1, from 1 to 150 U⋅mL-1 for CA125, and from 0.1 to 100 ng⋅mL-1 for SCCA. The corresponding detection limits are 0.2 ng⋅mL-1, 0.9 ng⋅mL-1, 0.4 ng⋅mL-1, 0.9 U⋅mL-1 and 30 pg⋅mL-1, respectively. The immunoassay was applied to the analysis of human serum samples, and the results were found to agree well with those of the enzyme-linked immunosorbent assay.
引用
收藏
页码:2889 / 2897
页数:8
相关论文
共 50 条
  • [1] Simultaneous detection of five biomarkers of lung cancer by electrochemical immunoassay
    Shan, Jiao
    Ma, Zhanfang
    MICROCHIMICA ACTA, 2016, 183 (11) : 2889 - 2897
  • [2] Electrochemical immunoassay for the detection of stress biomarkers
    Abdulsattar, Jwan O.
    Greenway, Gillian M.
    Wadhawan, Jay D.
    HELIYON, 2020, 6 (03)
  • [3] Electrochemical biosensors for the detection of lung cancer biomarkers: A review
    Khanmohammadi, Akbar
    Aghaie, Ali
    Vahedi, Ensieh
    Qazvini, Ali
    Ghanei, Mostafa
    Afkhami, Abbas
    Hajian, Ali
    Bagheri, Hasan
    TALANTA, 2020, 206
  • [4] Redox-labelled detection probe enabled immunoassay for simultaneous detection of multiple cancer biomarkers
    Chellachamy Anbalagan, Amarnath
    Sawant, Shilpa N.
    MICROCHIMICA ACTA, 2023, 190 (03)
  • [5] Redox-labelled detection probe enabled immunoassay for simultaneous detection of multiple cancer biomarkers
    Amarnath Chellachamy Anbalagan
    Shilpa N. Sawant
    Microchimica Acta, 2023, 190
  • [6] Simultaneous Multianalyte Immunoassay Measurement of Five Serum Tumor Markers in the Detection of Colorectal Cancer
    Lumachi, Franco
    Marino, Filippo
    Orlando, Rocco
    Chiara, Giordano B.
    Basso, Stefano M. M.
    ANTICANCER RESEARCH, 2012, 32 (03) : 985 - 988
  • [7] Simultaneous Electrochemical Multiplexed Immunoassay of Biomarkers Based on Multifunctionalized Graphene Nanotags
    Li, Qunfang
    Tang, Dianping
    Lou, Fangming
    Yang, Ximei
    Chen, Guonan
    CHEMELECTROCHEM, 2014, 1 (02): : 441 - 447
  • [8] Electrochemical immunosensor for simultaneous detection of multiplex cancer biomarkers based on graphene nanocomposites
    Chen, Xia
    Jia, Xinle
    Han, Jingman
    Ma, Jie
    Ma, Zhanfang
    BIOSENSORS & BIOELECTRONICS, 2013, 50 : 356 - 361
  • [9] Five years of advances in electrochemical analysis of protein biomarkers in lung cancer: a systematic review
    Regiart, Matias
    Fernandez-Baldo, Martin A.
    Navarrete, Bernardino Alcazar
    Garcia, Concepcion Morales
    Gomez, Beatriz
    Tortella, Gonzalo R.
    Valero, Teresa
    Ortega, Francisco Gabriel
    FRONTIERS IN CHEMISTRY, 2024, 12
  • [10] Detection of biomarkers for inflammatory diseases by an electrochemical immunoassay: The case of neopterin
    Centi, Sonia
    Tombelli, Sara
    Puntoni, Mariarita
    Domenici, Claudio
    Franek, Milan
    Palchetti, Ilaria
    TALANTA, 2015, 134 : 48 - 53