Probing the influence of graphene oxide sheets size on the performance of label-free electrochemical biosensors

被引:0
|
作者
Shimaa Eissa
Jeanne N’diaye
Patrick Brisebois
Ricardo Izquierdo
Ana C. Tavares
Mohamed Siaj
机构
[1] Université du Québec à Montréal,Dept. de Chimie et Biochimie, NanoQAM, QCAM/CQMF
[2] Institut National de la Recherche Scientifique – Énergie,Department of Chemistry
[3] Matériaux et Télécommunications,undefined
[4] Alfaisal University,undefined
来源
关键词
D O I
暂无
中图分类号
学科分类号
摘要
The integration of graphene materials into electrochemical biosensing platforms has gained significant interest in recent years. Bulk quantities of graphene can be synthesized by oxidation of graphite to graphite oxide and subsequent exfoliation to graphene oxide (GO). However, the size of the resultant GO sheets changes from the parent graphite yielding a polydispersed solution of sizes ranging from a few nanometers to tens of micrometers. Here, we investigate the direct effect of GO sheets sizes on biosensor performance. We separated different GO sheets sizes, and we characterized them via atomic force, scanning electron, Raman and X-ray photoelectron spectroscopies and solid state nuclear magnetic resonance (NMR). As proof of concept, the sensing performance of these GO samples was probed using a well-known ssDNA aptasensor against microcystin-LR toxin and an immunosensor against β-lactoglobulin. The resulting aptasensors and immunosensors are fabricated by using covalent attachment and physical adsorption. We found that the aptasensors fabricated using physical adsorption, the binding signal variation was dramatically increased with increasing the GO sheet size. In contrast, for the aptasensor fabricated using covalent immobilization, the binding signal variation decreased with increasing GO sheet size. However, for the β-lactoglobulin immunosensors, the optimum signals were observed at intermediate GO sheet size. GO sheet size could enhance or inhibit the sensitivity of the graphene-based electrochemical sensors. Our results demonstrate that controlling the size of GO sheets may have a profound impact in specific biosensing applications.
引用
收藏
相关论文
共 50 条
  • [31] Label-Free and Regenerative Electrochemical Microfluidic Biosensors for Continual Monitoring of Cell Secretomes
    Shin, Su Ryon
    Kilic, Tugba
    Zhang, Yu Shrike
    Avci, Huseyin
    Hu, Ning
    Kim, Duckjin
    Branco, Cristina
    Aleman, Julio
    Massa, Solange
    Silvestri, Antonia
    Kang, Jian
    Desalvo, Anna
    Hussaini, Mohammed Abdullah
    Chae, Su-Kyoung
    Polini, Alessandro
    Bhise, Nupura
    Hussain, Mohammad Asif
    Lee, HeaYeon
    Dokmeci, Mehmet R.
    Khademhosseini, Ali
    ADVANCED SCIENCE, 2017, 4 (05):
  • [32] Label-Free Electrochemical Biosensors for the Determination of Flaviviruses: Dengue, Zika, and Japanese Encephalitis
    Khristunova, Ekaterina
    Dorozhko, Elena
    Korotkova, Elena
    Kratochvil, Bohumil
    Vyskocil, Vlastimil
    Barek, Jiri
    SENSORS, 2020, 20 (16) : 1 - 24
  • [33] Size and time dependent internalization of label-free nano-graphene oxide in human macrophages
    Mendes, Rafael G.
    Mandarino, Angelo
    Koch, Britta
    Meyer, Anne K.
    Bachmatiuk, Alicja
    Hirsch, Cordula
    Gemming, Thomas
    Schmidt, Oliver G.
    Liu, Zhongfan
    Ruemmeli, Mark H.
    NANO RESEARCH, 2017, 10 (06) : 1980 - 1995
  • [34] Label-free fluorescent and electrochemical biosensors based on defective G-quadruplexes
    Zhang, Jing
    Wang, Liang-Liang
    Hou, Mei-Feng
    Luo, Li-Pei
    Liao, Yi-Juan
    Xia, Yao-Kun
    Yan, An
    Weng, Yun-Ping
    Zeng, Lu-Peng
    Chen, Jing-Hua
    BIOSENSORS & BIOELECTRONICS, 2018, 118 : 1 - 8
  • [35] Recent advances in label-free optical, electrochemical, and electronic biosensors for glioma biomarkers
    Saha, Soumyadeep
    Sachdev, Manoj
    Mitra, Sushanta K.
    BIOMICROFLUIDICS, 2023, 17 (01)
  • [36] Label-free electrochemical monitoring of vasopressin in aptamer-based microfluidic biosensors
    He, Peng
    Oncescu, Vlad
    Lee, Seoho
    Choi, Inhee
    Erickson, David
    ANALYTICA CHIMICA ACTA, 2013, 759 : 74 - 80
  • [37] Size and time dependent internalization of label-free nano-graphene oxide in human macrophages
    Rafael G. Mendes
    Angelo Mandarino
    Britta Koch
    Anne K. Meyer
    Alicja Bachmatiuk
    Cordula Hirsch
    Thomas Gemming
    Oliver G. Schmidt
    Zhongfan Liu
    Mark H. Rümmeli
    Nano Research, 2017, 10 : 1980 - 1995
  • [38] Label-free electrochemical aptasensor for detection of Acinetobacter baumannii : Unveiling the kinetic behavior of reduced graphene oxide v/s graphene oxide
    Singhal, Chaitali
    Gupta, Shruti
    Dhingra, Jyoti
    Pandey, Sweta
    Chatterjee, Sudarshana
    Bargakshatriya, Rupa
    Avasthi, Devesh Kumar
    Pramanik, Sumit
    Chaudhuri, Susmita
    ELECTROCHIMICA ACTA, 2024, 492
  • [39] Label-free optical biosensors in the pandemic era
    Nava, Giovanni
    Zanchetta, Giuliano
    Giavazzi, Fabio
    Buscaglia, Marco
    NANOPHOTONICS, 2022, 11 (18) : 4159 - 4181
  • [40] Emerging applications of label-free optical biosensors
    Zanchetta, Giuliano
    Lanfranco, Roberta
    Giavazzi, Fabio
    Bellini, Tommaso
    Buscaglia, Marco
    NANOPHOTONICS, 2017, 6 (04) : 627 - 645