Variation in segmentation of bone from micro-CT imaging: implications for quantitative morphometric analysis
被引:0
|
作者:
I. H. Parkinson
论文数: 0引用数: 0
h-index: 0
机构:Institute of Medical and Veterinary Science and Hanson Institute,Bone and Joint Research Laboratory, Division of Tissue Pathology
I. H. Parkinson
A. Badiei
论文数: 0引用数: 0
h-index: 0
机构:Institute of Medical and Veterinary Science and Hanson Institute,Bone and Joint Research Laboratory, Division of Tissue Pathology
A. Badiei
N. L. Fazzalari
论文数: 0引用数: 0
h-index: 0
机构:Institute of Medical and Veterinary Science and Hanson Institute,Bone and Joint Research Laboratory, Division of Tissue Pathology
N. L. Fazzalari
机构:
[1] Institute of Medical and Veterinary Science and Hanson Institute,Bone and Joint Research Laboratory, Division of Tissue Pathology
来源:
Australasian Physics & Engineering Sciences in Medicine
|
2008年
/
31卷
关键词:
image segmentation;
micro-CT;
tomographs;
bias;
random error;
cancellous bone;
D O I:
暂无
中图分类号:
学科分类号:
摘要:
Segmentation of bone in grey-level tomographs from micro-CT imaging is critical in determining the accuracy of morphometric analysis. The degree of variability in image segmentation between and within multiple operators will be quantified and compared with automated image segmentation. Three cubes of cancellous bone were cut from T12, L1, L3 and L4 human vertebral bodies (n=12). Micro-CT imaging was performed and a global threshold was determined by 3 operators independently and automatically using Otsu′s algorithm. Bone volume, trabecular thickness, trabecular separation, trabecular number, trabecular bone pattern factor, structure model index and degree of anisotropy were calculated. Percent bias and percent random error were calculated between all operators and Otsu’s method. For BV/TV, the maximum percent bias and percent random error were 22.0% and 11.3%, respectively, which constitutes differences in individual measurements between operators of up to 0.07. For Tb.Th, the maximum percent bias and percent random error were 13.1% and 6.4%, respectively, which constitutes differences in individual measurements between operators of up to 35μm. These data highlight to users of micro-CT imaging that morphometric analysis is highly sensitive to operating parameters. The effect on measurements of cancellous bone structure of different operators can be greater than experimental differences, which can lead to erroneous interpretation of results.
机构:
Nihon Univ, Grad Sch Dent, Div Appl Oral Sci, Tokyo 1018310, JapanNihon Univ, Grad Sch Dent, Div Appl Oral Sci, Tokyo 1018310, Japan
Udagawa, Asami
Sato, Shuichi
论文数: 0引用数: 0
h-index: 0
机构:
Nihon Univ, Sch Dent, Dept Periodontol, Tokyo 1018310, Japan
Nihon Univ, Sch Dent, Dent Res Ctr, Div Adv Dent Treatment, Tokyo 1018310, JapanNihon Univ, Grad Sch Dent, Div Appl Oral Sci, Tokyo 1018310, Japan
Sato, Shuichi
Hasuike, Akira
论文数: 0引用数: 0
h-index: 0
机构:
Nihon Univ, Grad Sch Dent, Div Appl Oral Sci, Tokyo 1018310, JapanNihon Univ, Grad Sch Dent, Div Appl Oral Sci, Tokyo 1018310, Japan
Hasuike, Akira
Kishida, Mamoru
论文数: 0引用数: 0
h-index: 0
机构:
Nihon Univ, Sch Dent, Dept Periodontol, Tokyo 1018310, JapanNihon Univ, Grad Sch Dent, Div Appl Oral Sci, Tokyo 1018310, Japan
Kishida, Mamoru
Arai, Yoshinori
论文数: 0引用数: 0
h-index: 0
机构:
Nihon Univ, Sch Dent, Tokyo 1018310, JapanNihon Univ, Grad Sch Dent, Div Appl Oral Sci, Tokyo 1018310, Japan
Arai, Yoshinori
Ito, Koichi
论文数: 0引用数: 0
h-index: 0
机构:
Nihon Univ, Sch Dent, Dept Periodontol, Tokyo 1018310, Japan
Nihon Univ, Sch Dent, Dent Res Ctr, Div Adv Dent Treatment, Tokyo 1018310, JapanNihon Univ, Grad Sch Dent, Div Appl Oral Sci, Tokyo 1018310, Japan