On the full stand modeling and tension control for the hot strip finishing mill with PID structure

被引:0
作者
Byoung Joon Ahn
Ju Yong Choi
Yu Shin Chang
Man Hyung Lee
机构
[1] Pusan National University,Department of Mechanical and Intelligent Systems Engineering
[2] Pusan National University,Department of Mechanical and Intelligent Systems Engineering
[3] ERC/NSDM Pusan National University,Department of Mechanical and Intelligent Systems Engineering
[4] Pusan National University,School of Mechanical Engineering
来源
KSME International Journal | 2004年 / 18卷
关键词
Hot Strip Finishing Mill; Tension; Looper System; Conventional PI; Cross Control; CDM;
D O I
暂无
中图分类号
学科分类号
摘要
We describe a looper controller design for a hot strip finishing mill in steel plants. The main function of the looper system is to balance the mass flow of the strip by accumulating material in the middle of the stands. Another function is to control the strip tension which influences the width of the strip. To ensure strip quality, it is very important to control the tension of the hot strip finishing mill. However, because there is a mutual interaction between the looper angle and the strip tension, it is difficult to control the looper system. Previous researches examined only the operation of a single stand. But it is not sufficient to examine the operation and effect of whole stands because the operation is wholly interdependent. In this paper, we present a full model of the hot strip finishing mill in order to more effectively control strip tension. We propose several control methods for the full-stand hot strip finishing mill, denoted as conventional PI, PI with cross gain, and coefficient diagram method (CDM) PID control. In the real plants, there are some problems by using higher order controllers such as LQ, LQG and H∞. By comparison, the PID controller is very simple and easy to apply to all real plants. To that end, we present our findings on PID controls and their potential use in the hot strip finishing mill.
引用
收藏
页码:1062 / 1073
页数:11
相关论文
共 8 条
[1]  
Hesketh T.(1998)Controller Design for Hot Strip Finishing Mills IEEE Trans, on Control System Techology 6 208-219
[2]  
Jiang Y. A.(1998)Real-Time Tension Control in a Multi-Stand Rolling System KSME International Journal 12 12-21
[3]  
Climents D. J.(2001)Application of CDM to MIMO System : Control of Hot Rolling Mill Transactions on Control, Automation and Systems Engineering 3 250-256
[4]  
Butler D. H.(undefined)undefined undefined undefined undefined-undefined
[5]  
van der Laan R.(undefined)undefined undefined undefined undefined-undefined
[6]  
Shin K. H.(undefined)undefined undefined undefined undefined-undefined
[7]  
Hong W. K.(undefined)undefined undefined undefined undefined-undefined
[8]  
Young-Choi Kim(undefined)undefined undefined undefined undefined-undefined