Accurate description and modeling of fouling on hollow fibers imposes a serious challenge to more effective fouling mitigation and performance optimization of the membrane system. Although the governing equations for membrane fouling can be constructed based on the known theories from membrane filtration and fluid dynamics, they are unsolvable analytically due to the complex spatially and temporally varying nature of fouling on hollow fibers. The current available numerical solutions for the governing equations are either unreliable or inconvenient to use because of the uses of unfounded assumptions or cumbersome calculation methods. This work presented for the first time a rigorous numerical procedure to solve the governing equations for fouling development on hollow fibers. A critical step to achieve the goal is the use of bisection method to determine the transmembrane pressure at the dead end of the fibers. With this procedure, fouling behavior in the hollow fiber membrane system under a given condition can be simulated within a second. The model simulations were well calibrated and verified with the published experimental data from literature. Also presented in the paper were simulations for performances of the hollow fiber membrane system under various operation conditions.
引用
收藏
页码:14346 / 14354
页数:8
相关论文
共 102 条
[11]  
Carroll T(2001)Hydrophobic hollow fiber membranes for treating MTBE-contaminated water Environ Sci Technol 35 1875-1879
[12]  
Carroll T(2011)Laminar flow with injection through a long dead-end cylindrical porous tube: application to a hollow fiber membrane AICHE J 57 1997-2006
[13]  
Booker NA(2011)Determination of MBR fouling and chemical cleaning interval using statistical methods applied on dynamic index data J Membr Sci 375 345-353
[14]  
Chang S(2012)Analysis of local fouling in a pilot-scale submerged hollow-fiber membrane system for drinking water treatment by membrane autopsy Sep Purif Technol 95 227-234
[15]  
Fane AG(2005)Prediction model for transmembrane pressure in a submerged hollow-fiber microfiltration membrane Sep Sci Technol 39 1833-1856
[16]  
Chang S(2008)Analysis of filtration characteristics in submerged microfiltration for drinking water treatment Water Res 42 3109-3121
[17]  
Fane AG(2014)Experimental investigation of local flux distribution and fouling behavior in double-end and dead-end submerged hollow fiber membrane modules J Membr Sci 453 18-26
[18]  
Vigneswaran S(2015)A filtration model for prediction of local flux distribution and optimization of submerged hollow fiber membrane module AICHE J 61 4377-4386
[19]  
Chang S(2016)Modeling of filtration characteristics during submerged hollow fiber membrane microfiltration of yeast suspension under aeration condition J Membr Sci 510 455-465
[20]  