Single versus double row suture anchor fixation for greater tuberosity fractures – a biomechanical study

被引:0
作者
Gernot Seppel
Tim Saier
Frank Martetschläger
Johannes E. Plath
Alberto Guevara-Alvarez
Julia Henschel
Martin Winkler
Peter Augat
Andreas B. Imhoff
Stefan Buchmann
机构
[1] Klinikum rechts der Isar,Department of Orthopedic Sports Medicine
[2] Technical University Munich,Department of Orthopedics and Trauma Surgery
[3] Krankenhaus Barmherzige Brüder,Department of Reconstructive Joint Surgery and Sportstraumatology
[4] Berufsgenossenschaftliche Unfallklinik Murnau,Center for Shoulder and Elbow Surgery
[5] ATOS Clinic Munich,Department of Trauma Surgery
[6] Klinikum Augsburg,Institute of Biomechanics
[7] Berufsgenossenschaftliche Unfallklinik Murnau,Institute of Biomechanics
[8] Paracelsus Medical University,undefined
[9] Orthopädisches Fachzentrum,undefined
来源
BMC Musculoskeletal Disorders | / 18卷
关键词
Greater tuberosity fracture; Suture anchor; Arthroscopic; Double row fixation; Single-row;
D O I
暂无
中图分类号
学科分类号
摘要
引用
收藏
相关论文
共 127 条
[1]  
Bahrs C(2006)Mechanism of injury and morphology of the greater tuberosity fracture Journal of shoulder and elbow surgery/American Shoulder and Elbow Surgeons [et al.] 15 140-147
[2]  
Lingenfelter E(2001)Effect of displacement of fractures of the greater tuberosity on the mechanics of the shoulder The Journal of bone and joint surgery British volume 83 1056-1062
[3]  
Fischer F(2007)Operative treatment of greater tuberosity fractures of the humerus--a biomechanical analysis Clin Biomech 22 652-657
[4]  
Walters EM(2000)A stepwise approach to arthroscopic rotator cuff repair based on biomechanical principles Arthroscopy : the journal of arthroscopic & related surgery : official publication of the Arthroscopy Association of North America and the International Arthroscopy Association 16 82-90
[5]  
Schnabel M(1991)Open reduction and internal fixation of two-part displaced fractures of the greater tuberosity of the proximal part of the humerus The Journal of bone and joint surgery American 73 1213-1218
[6]  
Bono CM(2003)Isolated fractures of the greater tuberosity of the proximal humerus Journal of shoulder and elbow surgery/American Shoulder and Elbow Surgeons [et al] 12 641-649
[7]  
Renard R(2006)Fixation of greater tuberosity fractures: a biomechanical comparison of three techniques Bulletin 63 98-99
[8]  
Levine RG(2010)Arthroscopic fixation technique for comminuted, displaced greater tuberosity fracture Arthroscopy : the journal of arthroscopic & related surgery : official publication of the Arthroscopy Association of North America and the International Arthroscopy Association 26 600-609
[9]  
Levy AS(2007)Outcomes after percutaneous reduction and fixation of proximal humeral fractures Journal of shoulder and elbow surgery/American Shoulder and Elbow Surgeons [et al.] 16 330-338
[10]  
Braunstein V(2014)Arthroscopic reduction and internal fixation for displaced anterior glenoid rim and greater tuberosity fractures Journal of orthopaedic science : official journal of the Japanese Orthopaedic Association 19 497-501