Pesticide analysis at ppt concentration levels: coupling nano-liquid chromatography with dielectric barrier discharge ionization-mass spectrometry

被引:0
|
作者
Mario F. Mirabelli
Jan-Christoph Wolf
Renato Zenobi
机构
[1] ETH Zurich,Department of Chemistry and Applied Biosciences
[2] Plasmion UG,undefined
来源
Analytical and Bioanalytical Chemistry | 2016年 / 408卷
关键词
DBDI; Nano-liquid chromatography; Active capillary plasma ionization; Ambient ionization; Pesticides; QuEChERS;
D O I
暂无
中图分类号
学科分类号
摘要
We report the coupling of nano-liquid chromatography (nano-LC) with an ambient dielectric barrier discharge ionization (DBDI)-based source. Detection and quantification were carried out by high-resolution mass spectrometry (MS), using an LTQ-Orbitrap in full scan mode. Despite the fact that nano-LC systems are rarely used in food analysis, this coupling was demonstrated to deliver extremely high sensitivity in pesticide analysis, with limits of detection (LODs) as low as 10 pg/mL. In all cases, the limits of quantification (LOQs) were compliant with the current EU regulation. An excellent signal linearity over up to four orders of magnitude was also observed. Therefore, this method can easily compete with conventional GC-(EI)-MS or LC-ESI-MS/MS methods and in some cases outperform them. The method was successfully tested for food sample analysis, with apples and baby food, extracted using the QuEChERS approach. Our results demonstrate an outstanding sensitivity (at femtogram level) and reproducibility of the nano-LC-DBDI coupling, capable of improving routine pesticide analysis. To the best of our knowledge, this is the most sensitive and reproducible plasma-MS-based method for pesticide analysis reported to date.
引用
收藏
页码:3425 / 3434
页数:9
相关论文
共 50 条
  • [1] Pesticide analysis at ppt concentration levels: coupling nano-liquid chromatography with dielectric barrier discharge ionization-mass spectrometry
    Mirabelli, Mario F.
    Wolf, Jan-Christoph
    Zenobi, Renato
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2016, 408 (13) : 3425 - 3434
  • [2] Use of dielectric barrier discharge ionization to minimize matrix effects and expand coverage in pesticide residue analysis by liquid chromatography-mass spectrometry
    Lara-Ortega, Felipe J.
    Robles-Molina, Jose
    Brandt, Sebastian
    Schuetz, Alexander
    Gilbert-Lopez, Bienvenida
    Molina-Diaz, Antonio
    Garcia-Reyes, Juan F.
    Franzke, Joachim
    ANALYTICA CHIMICA ACTA, 2018, 1020 : 76 - 85
  • [3] Pressurized nano-liquid-junction interface for coupling capillary electrochromatography and nano-liquid chromatography with mass spectrometry
    D'Orazio, Giovanni
    Fanali, Salvatore
    JOURNAL OF CHROMATOGRAPHY A, 2013, 1317 : 67 - 76
  • [4] Nano-liquid chromatography-direct electron ionization mass spectrometry: improving performance by a new ion source adapter
    Flender, Cornelia
    Wolf, Christian
    Leonhard, Peter
    Karas, Michael
    JOURNAL OF MASS SPECTROMETRY, 2011, 46 (10): : 1004 - 1010
  • [5] Nano-liquid chromatography and capillary electrochromatography hyphenated with mass spectrometry for tryptic digest protein analysis: A comparison
    Fanali, Chiara
    D'Orazio, Giovanni
    Fanali, Salvatore
    ELECTROPHORESIS, 2012, 33 (16) : 2553 - 2560
  • [6] Impact of homogeneous and filamentary discharge modes on the efficiency of dielectric barrier discharge ionization mass spectrometry
    Cordula Meyer
    Saskia Müller
    Bienvenida Gilbert-Lopez
    Joachim Franzke
    Analytical and Bioanalytical Chemistry, 2013, 405 : 4729 - 4735
  • [7] Impact of homogeneous and filamentary discharge modes on the efficiency of dielectric barrier discharge ionization mass spectrometry
    Meyer, Cordula
    Mueller, Saskia
    Gilbert-Lopez, Bienvenida
    Franzke, Joachim
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2013, 405 (14) : 4729 - 4735
  • [8] Chiral nano-liquid chromatography-mass to amino acids analysis for orange spectrometry applied juice profiling
    D'Orazio, Giovanni
    Cifuentes, Alejandro
    Fanali, Salvatore
    FOOD CHEMISTRY, 2008, 108 (03) : 1114 - 1121
  • [9] THE PROTEOME ANALYSIS OF RAT PLATELET WITH NANO-LIQUID CHROMATOGRAPHY-MATRIX-ASSISTED LASER DESORPTION/IONIZATION TIME-OF-FLIGHT MASS SPECTROMETRY TECHNIQUE
    Gromotowicz-Poplawska, A.
    Kasprzyk, J.
    Marcinczyk, N.
    Stepien, E.
    Piekoszewski, W.
    Chabielska, E.
    JOURNAL OF PHYSIOLOGY AND PHARMACOLOGY, 2018, 69 (06): : 963 - 968
  • [10] Determination of carbamate pesticide residues in vegetables and fruits by liquid chromatography-atmospheric pressure photoionization-mass spectrometry and atmospheric pressure chemical ionization-mass spectrometry
    Takino, M
    Yamaguchi, K
    Nakahara, T
    JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2004, 52 (04) : 727 - 735