Wide and fast wavelength-swept fiber lasers based on dispersion tuning and their application to optical coherence tomography

被引:25
|
作者
Yamashita S. [1 ]
Takubo Y. [1 ]
机构
[1] Research Center for Advanced Science and Technology (RCAST), University of Tokyo, 4-6-1 Komaba, Meguro-ku
基金
日本学术振兴会;
关键词
dispersion tuning; OCT; swept lasers;
D O I
10.1007/s13320-013-0129-0
中图分类号
学科分类号
摘要
We recently proposed a new class of wavelength-swept lasers for swept-source optical coherence tomography (SS-OCT). It uses the same gain medium with the conventional swept lasers, but does not require any tunable filters. It is based on a principle called "dispersion tuning", in which a highly dispersive medium is inserted in the laser cavity, and loss/gain modulation is applied to mode-lock the laser. Since the cavity contains no mechanical components, such as tunable filters, we could achieve the very high sweep rate. In this review paper, we describe the principle of the dispersion-tuned swept lasers in detail and present our recent work on the application to the SS-OCT system. © 2013 The Author(s).
引用
收藏
页码:320 / 331
页数:11
相关论文
共 50 条
  • [41] Megahertz ultra-wide-field swept-source retina optical coherence tomography compared to current existing imaging devices
    Lukas Reznicek
    Thomas Klein
    Wolfgang Wieser
    Marcus Kernt
    Armin Wolf
    Christos Haritoglou
    Anselm Kampik
    Robert Huber
    Aljoscha S. Neubauer
    Graefe's Archive for Clinical and Experimental Ophthalmology, 2014, 252 : 1009 - 1016
  • [42] Evaluation of a swept-laser optical coherence tomography light source based on a novel quantum-dot based semiconductor optical amplifier
    Krstajic, Nikola
    Childs, David
    Peyvast, Negin
    Kasaragod, Deepa
    Matcher, Stephen J.
    Krestnikov, Igor
    Hogg, Richard
    OPTICAL COHERENCE TOMOGRAPHY AND COHERENCE TECHNIQUES V, 2011, 8091
  • [43] Kalman-Based Real-Time Functional Decomposition for the Spectral Calibration in Swept Source Optical Coherence Tomography
    Zavareh, Amir Tofighi
    Hoyos, Sebastian
    IEEE TRANSACTIONS ON BIOMEDICAL CIRCUITS AND SYSTEMS, 2020, 14 (02) : 257 - 273
  • [44] Impact of lens opacity and axial length on concomitant screening of maculopathy by swept-source optical coherence tomography-based optical biometer
    Qin, Yingyan
    Ye, Shaobi
    Liu, Liangping
    Wu, Mingxing
    ANNALS OF TRANSLATIONAL MEDICINE, 2022, 10 (15)
  • [45] Dual-core ytterbium fiber amplifier for high-power 1060 nm swept source multichannel optical coherence tomography imaging
    Harduar, Mark K.
    Mariampillai, Adrian
    Vuong, Barry
    Gu, Xijia
    Standish, Beau A.
    Yang, Victor X. D.
    OPTICS LETTERS, 2011, 36 (15) : 2976 - 2978
  • [46] Chromatic dispersion based axial length estimation using retinal spectral domain optical coherence tomography
    Kuebler, Johannes
    Fischer, JoeRG P.
    DE Boer, Johannes f.
    BIOMEDICAL OPTICS EXPRESS, 2025, 16 (02): : 793 - 805
  • [47] Long-range and wide field of view optical coherence tomography for in vivo 3D imaging of large volume object based on akinetic programmable swept source
    Song, Shaozhen
    Xu, Jingjiang
    Wang, Ruikang K.
    BIOMEDICAL OPTICS EXPRESS, 2016, 7 (11): : 4734 - 4748
  • [48] Retinal choroidal vessel imaging based on multi-wavelength fundus imaging with the guidance of optical coherence tomography
    Huang, Zhiyu
    Jiang, Zhe
    Hu, Yicheng
    Zou, Da
    Yu, Yue
    Ren, Qiushi
    Liu, Gangjun
    Lu, Yanye
    BIOMEDICAL OPTICS EXPRESS, 2020, 11 (09) : 5212 - 5224
  • [49] All-fiber wavelength swept ring laser based on Fabry-Perot filter for optical frequency domain imaging
    Jun, Changsu
    Villiger, Martin
    Oh, Wang-Yuhl
    Bouma, Brett E.
    OPTICS EXPRESS, 2014, 22 (21): : 25805 - 25816
  • [50] Spectrally encoded common-path fiber-optic-based parallel optical coherence tomography
    Lee, Kye-Sung
    Hur, Hwan
    Sung, Ha-Young
    Kim, I. Jong
    Kim, Geon-Hee
    OPTICS LETTERS, 2016, 41 (18) : 4241 - 4244