Reusable Electrical Activity of the Heart Monitoring Patch for Mobile/Ubiquitous Healthcare

被引:0
作者
Jeong-Whan Lee
Kang-Hwi Lee
Young-Jae Lee
Lee-Yon Hong
Dong-Jun Kim
Kyeong-Seop Kim
Bongsoo Lee
Myoungho Lee
机构
[1] Konkuk University,School of Biomedical Engineering, Research Institute of Biomedical Engineering, College of Biomedical and Life Science
[2] Chongju University,School of Computer and Communication Engineering
[3] Yonsei University,Department of Electrical and Electronic Engineering
来源
Journal of Medical Systems | 2009年 / 33卷
关键词
Concentric ring; Electrode; Electrical activity of the heart; Physiological signal monitoring; Mobile/ubiquitous healthcare;
D O I
暂无
中图分类号
学科分类号
摘要
In order to monitor electrical activity of the heart during daily life, we present an electrode of a medical instrument system which is able to measure the body surface potential difference by minimizing the electrode distance. The designed electrode is composed of concentric circles. It was made from the basis of the Laplacian equation, and implemented on PCB coated with gold. So that it does not cause the uncomfortable feeling of contact and possible skin troubles which are typical shortcoming of the conventional ECG measurement. The suggested method utilized three concentric circles on FR-4 substrate, so new amplifier design regarding measuring of small biological signal, is considered which has the characteristics of asymmetric input impedance since the area of concentric circular ring electrodes is not identical. Thereby, electrical activity of the heart was obtained successfully. However, its signal quality is a little bit degraded and the motion artifact still remains as a major problem as is in conventional electrocardiography measurement. Certainly stable measurement setup was needed to reduce the motion artifact originated from variation in static electricity between skin and electrode interfaces.
引用
收藏
页码:41 / 46
页数:5
相关论文
共 10 条
  • [1] Hjorth B.(1975)An on-line transformation of EEG scalp potentials into orthogonal source derivation Electroencephalogr. Clin. Neurophysiol 39 526-530
  • [2] He B.(1992)Body surface ECG Laplacian mapping IEEE Trans. Biomed. Eng BME-39 1179-1191
  • [3] Cohen R. J.(1971)Electrocardiogram recording with pasteless electrode IEEE Trans. Biomed. Eng BME-18 206-211
  • [4] Bergey G. E.(2000)A micropower dry-electrode ECG preamplifier IEEE Trans. Biomed. Eng 47 155-162
  • [5] Squires R. D.(1969)The performance of transistor ECG amplifier World Medical Instruments 7 12-22
  • [6] Sipple W. C.(undefined)undefined undefined undefined undefined-undefined
  • [7] Burke M. J.(undefined)undefined undefined undefined undefined-undefined
  • [8] Gleeson D. T.(undefined)undefined undefined undefined undefined-undefined
  • [9] Hill O. W.(undefined)undefined undefined undefined undefined-undefined
  • [10] Khandpur R. S.(undefined)undefined undefined undefined undefined-undefined