Coronary vessel visualization using true 16-row multi-slice computed tomography technology

被引:0
作者
Axel Kuettner
Christof Burgstahler
Torsten Beck
Tanja Drosch
Andreas F. Kopp
Martin Heuschmid
Claus D. Claussen
Stephen Schroeder
机构
[1] Eberhard-Karls-University,Department of Diagnostic Radiology
[2] Eberhard-Karls-University Tuebingen,Department of Internal Medicine, Division of Cardiology
来源
The International Journal of Cardiovascular Imaging | 2005年 / 21卷
关键词
coronary artery disease; image quality; imaging technique; multi-slice computed tomography; 16 row;
D O I
暂无
中图分类号
学科分类号
摘要
Background :Multi-slice computed tomography (MSCT) scanners with retrospective ECG-gating permit visualization of the coronary arteries. Limited spatial and temporal resolution as well as breathing artefacts due to the scan time can cause poor distal vessel segment and side branch visualization. The latest MSCT generation with true 16-detector slices (Sensation 16 ®, Siemens, Forchheim, Germany) provides furthermore improved temporal and spatial resolution, as well as significantly reduced scan time. To assess, whether this technical improvement has also an impact on image quality we conducted the following study. Methods and material :Sixty-two consecutive patients (33 male, 29 female, mean age 63±8 [47–79] years, heart rate after β-blockade 63±7 [45–86] bpm) with suspicion of coronary artery disease (CAD) were examined by cardiac MSCT. Parameter settings were: 0.75mm collimation, 2.8mm table feed/rotation, caudocranial scan direction, 80cc contrast media biphasic injection protocol, gantry rotation time 375ms, temporal resolution 188ms). Thirteen coronary segments (sgts) were evaluated in each patient (total number: 806sgts). Image quality of each segment was determined as: excellent – free of motion artefacts, good – mild motion artefacts, relevant artefacts – still diagnostic value, severe calcification and insufficient image quality – not visualized segment. Results :301/806 (37%) sgts showed excellent and 294/806 (36%) sgts good image quality. Relevant artefacts were seen in 107/806 (13%) sgts, calcifications in 41/806 (5%) sgts. 63/806 (8%) sgts could not be visualized (34 of them (54%) either segment 9 or 10). Diagnostic image quality was achieved in 702/806 (87%) sgts. Conclusions :Due to true 16-slice technology and faster gantry rotation time MSCT image quality could be improved and allows a visualization of the entire coronary tree. Larger, randomized, catheter-controlled studies have to be conducted to determine, whether this improved visualization also translates into better diagnostic accuracy.
引用
收藏
页码:331 / 337
页数:6
相关论文
共 50 条
  • [21] Multi-slice computed tomography assessment of bronchial compression with absent pulmonary valve
    Zhong, Yu-Min
    Jaffe, Richard B.
    Liu, Jin-Fen
    Sun, Ai-Min
    Gao, Wei
    Wang, Qian
    Zhu, Ming
    Qiu, Hai-Sheng
    Berdon, Walter E.
    PEDIATRIC RADIOLOGY, 2014, 44 (07) : 803 - 809
  • [22] Multi-slice computed tomography assessment of bronchial compression with absent pulmonary valve
    Yu-Min Zhong
    Richard B. Jaffe
    Jin-Fen Liu
    Ai-Min Sun
    Wei Gao
    Qian Wang
    Ming Zhu
    Hai-Sheng Qiu
    Walter E. Berdon
    Pediatric Radiology, 2014, 44 : 803 - 809
  • [23] Can multi-slice computed tomography of the heart be useful in patients with epicardial leads?
    Mlynarska, Agnieszka
    Mlynarski, Rafal
    Wilczek, Jacek
    Sosnowski, Maciej
    CARDIOLOGY JOURNAL, 2013, 20 (01) : 87 - 89
  • [24] Performance of approximate cone-beam reconstruction in multi-slice computed tomography
    Bruder, H
    Kachelriess, M
    Schaller, S
    Mertelmeier, T
    MEDICAL IMAGING 2000: IMAGE PROCESSING, PTS 1 AND 2, 2000, 3979 : 541 - 553
  • [25] Visualization of pulmonary vein stenosis after radio frequency ablation using multi-slice computed tomography: initial clinical experience in 33 patients
    Burgstahler, C
    Trabold, T
    Kuettner, A
    Kopp, AF
    Mewis, C
    Kuehlkamp, V
    Claussen, CD
    Schroeder, S
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2005, 102 (02) : 287 - 291
  • [26] The Diagnostic Performance of Multi-slice Coronary Computed Tomographic Angiography: a Systematic Review
    Ollendorf, Daniel A.
    Kuba, Michelle
    Pearson, Steven D.
    JOURNAL OF GENERAL INTERNAL MEDICINE, 2011, 26 (03) : 307 - 316
  • [27] The Diagnostic Performance of Multi-slice Coronary Computed Tomographic Angiography: a Systematic Review
    Daniel A. Ollendorf
    Michelle Kuba
    Steven D. Pearson
    Journal of General Internal Medicine, 2011, 26 : 307 - 316
  • [28] Assessment of left ventricular volumes and ejection fraction with 16-slice multi-slice computed tomography; comparison with 2D-echocardiography
    Schuijf, J. D.
    Bax, J. J.
    Jukema, J. W.
    Lamb, H. J.
    Salm, L. P.
    de Roos, A.
    van der Wall, E. E.
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2007, 116 (02) : 201 - 205
  • [29] Cone-Beam Computed Tomography vs. Multi-Slice Computed Tomography in paleoimaging: where we stand
    Izzetti, Rossana
    Gaeta, Raffaele
    Caramella, Davide
    Giuffra, Valentina
    HOMO-JOURNAL OF COMPARATIVE HUMAN BIOLOGY, 2020, 71 (01) : 63 - 72
  • [30] Non-invasive coronary angiography: the clinical value of multi-slice computed tomography in the assessment of patients with prior coronary bypass surgery
    von Kiedrowski, Helge
    Wiemer, Marcus
    Franzke, Krista
    Preuss, Rainer
    Vaske, Bernhard
    Butz, Thomas
    Oldenburg, Olaf
    Bitter, Thomas
    Mahmood, Khalid
    Burchert, Wolfram
    Horstkotte, Dieter
    Langer, Christoph
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2009, 25 (02) : 161 - 170