Assessment of myocardial perfusion with real-time myocardial contrast echocardiography: Methodology and clinical applications

被引:0
作者
Abdou Elhendy
Thomas R. Porter
机构
[1] University of Nebraska Medical Center,Department of Internal Medicine, Section of Cardiology
来源
Journal of Nuclear Cardiology | 2005年 / 12卷
关键词
Myocardial Perfusion; Wall Motion; Nuclear Cardiology; Dobutamine Stress; Dobutamine Stress Echocardiography;
D O I
暂无
中图分类号
学科分类号
摘要
Real-time myocardial contrast perfusion imaging (RTMCI) with echocardiography is a promising technique for evaluation of patients with known or suspected coronary artery disease. The technique is based on the utilization of small (<10 µm) microbubbles, which are capable of crossing the pulmonary circulation after intravenous injection. Unlike radioactive isotopes, which are taken actively or diffuse passively in the myocytes, myocardial contrast agents remain extracellularly in the capillaries and present a measure of the myocardial capillary blood volume and microvascular integrity. RTMCI has been shown to be a safe and feasible method for the assessment of myocardial perfusion at rest and with pharmacologie stress. Recent studies have shown the value of RTMCI with dobutamine stress in improving overall and regional detection of coronary artery disease and detecting of abnormalities at submaximal stress, therefore improving sensitivity in patients who are unable to achieve the target heart rate. The advantages of the technique include the ability to assess perfusion at bedside in one setting, simultaneous assessment of myocardial function, shorter imaging time, no need for ionizing irradiation, immediate availability of the results, and the ability to determine the ischemic threshold. Recent studies have shown that RTMCI improves the prognostic utility of standard dobutamine stress in addition to wall motion analysis. Patients with normal perfusion had a better outcome than those with normal wall motion. The combination of abnormal wall motion and perfusion identified patients at greatest risk of death and nonfatal myocardial infarction. Perfusion abnormalities were also shown to predict short-term cardiac events in patients presenting to the emergency department with chest pain and no ST-segment elevation. Refinement of imaging techniques is expected to improve the specificity of RTMCI, particularly in differentiating true perfusion defects from artifacts. This review will discuss the physiologic basis, methodology, clinical utility, and limitations of RTMCI in the assessment of patients with known or suspected coronary artery disease. (J Nucl Cardiol 2005;12:582-90.)
引用
收藏
页码:582 / 590
页数:8
相关论文
共 252 条
[1]  
Cheitlin MD(2003)ACC/AHA/ASE 2003 Guideline Update for the Clinical Application of Echocardiography: summary article. A report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines (ACC/AHA/ASE Committee to Update the 1997 Guidelines for the Clinical Application of Echocardiography J Am Soc Echocardiogr 16 1091-110
[2]  
Armstrong WF(1997)Methodology, feasibility, safety and diagnostic accuracy of dobutamine stress echocardiography J Am Coll Cardiol 30 595-606
[3]  
Aurigemma GP(2003)Direct effects of dobutamine on the coronary microcirculation: comparison with adenosine using myocardial contrast echocardiography J Am Soc Echocardiogr 16 871-9
[4]  
Beller GA(2001)comparative value of dobutamine and adenosine stress in the detection of coronary stenosis with myocardial contrast echocardiography Circulation 103 2724-30
[5]  
Bierman FZ(2002)Dobutamine versus dipyridamole in inducing reversible perfusion defects in chronic multivessel coronary artery stenosis J Am Coll Cardiol 40 167-74
[6]  
Davis JL(2002)Dobutamine stress myocardial perfusion imaging in coronary artery disease J Nucl Med 43 1634-46
[7]  
Geleijnse ML(2000)Accuracy of dobutamine technetium 99m sestamibi SPECT imaging for the diagnosis of single-vessel coronary artery disease: comparison with echocardiography Am Heart J 139 224-30
[8]  
Fioretti PM(1997)Gender differences in the accuracy of dobutamine stress echocardiography for the diagnosis of coronary artery disease Am J Cardiol 80 1414-8
[9]  
Roelandt JR(2002)Perfusion versus function: the ischemic cascade in demand ischemia: implications of single-vessel versus multivessel stenosis Circulation 105 987-92
[10]  
Bin JP(1996)Dobutamine-induced hypoperfusion without transient wall motion abnormalities: less severe ischemia or less severe stress? J Am Coll Cardiol 27 323-9