Preparation and Properties of Zn-Cu Alloy for Potential Stent Material

被引:0
作者
Jiajun Huang
Yonglai Lai
Hualan Jin
Hongmin Guo
Fanrong Ai
Qi Xing
Xiangjie Yang
David J. Ross
机构
[1] Nanchang University,School of Materials Science and Engineering
[2] Nanchang University,School of Mechanical and Electrical Engineering
[3] Mayo Clinic,Department of Cardiovascular Diseases
[4] Michigan Technological University,Department of Biomedical Engineering
来源
Journal of Materials Engineering and Performance | 2020年 / 29卷
关键词
biocompatibility; corrosion rate; mechanical properties; stent; zinc-copper alloys;
D O I
暂无
中图分类号
学科分类号
摘要
Among degradable metal cardiac stent materials, zinc has great biocompatibility and corrosion properties, which make it become the most potential stent material. However, the mechanical properties of zinc cannot meet the performance requirements of stent material which severely limit its application. In this paper, Zn-xCu (x = 1, 2 and 3 wt.%) alloys were prepared, and their mechanical properties, corrosion properties and biocompatibility were studied. Tensile testing showed the tensile strength and hardness of Zn-xCu alloys both increased with the addition of copper, but the elongation decreased at first and then upturned. Since the formation of galvanic cell, the corrosion rates of Zn-xCu alloys increased. The main corrosion mechanism of Zn-xCu alloy was pitting corrosion, and the corrosion products mainly included ZnO and Zn(OH)2. The cytotoxicity evaluation showed that Cu2+ and Zn2+ would contribute to cell proliferation, while the concentrations of them reached a suitable range like the concentration of soaking solution of Zn-3Cu alloy was 25%. However, it would inhibit proliferation, while the concentrations of Zn2+ and Cu2+ were too large. In general, Zn-3Cu alloy had the best comprehensive properties.
引用
收藏
页码:6484 / 6493
页数:9
相关论文
共 95 条
[1]  
Yılmaz E(2018)Mechanical Properties and Electrochemical Behavior of Porous Ti-Nb Biomaterials J. Mech. Behav. Biomed. Mater. 87 59-67
[2]  
Gökçe A(2018)Assessment of Ti-16Nb- J. Therm. Anal. Calorimet. 134 7-14
[3]  
Findik F(2013)Zr Alloys Produced Via PIM for Implant Applications Adv. Mater. 25 2577-566
[4]  
Gulsoy O(2015)Zinc Exhibits Ideal Physiological Corrosion Behavior for Bioabsorbable Stent Sci. Rep. 5 10719-1181
[5]  
Iyibilgin O(2016)Development of Biodegradable Zn-X Binary Alloys with Nutrient Alloying Elements Mg, Ca and Sr ACS Biomater. Sci. Eng. 2 634-3200
[6]  
Yılmaz E(2016)Endothelial Cellular Responses to Biodegradable Metal Zinc ACS Biomater. Sci. Eng. 2 634-692
[7]  
Gökçe A(2015)In vitro Cytotoxicity, Adhesion, and Proliferation of Human Vascular Cells Exposed to Zinc Mater. Sci. Eng., C 56 467-192
[8]  
Findik F(2015)Metallic Zinc Exhibits Optimal Biocompatibility for Bioabsorbable Endovascular Stents Mater. Sci. Eng., C 49 560-63
[9]  
Gulsoy O(2017)Cytotoxicity Evaluation of Biodegradable Zn-3 Mg Alloy Toward Normal Human Osteoblast Cells Mater. Sci. Eng., C 77 1170-640
[10]  
Bowen PK(2018)Fabrication, Mechanical Properties and in Vitro Degradation Behavior of Newly Developed ZnAg Alloys for Degradable Implant Applications Adv. Mod. Biomed. 18 3196-86