Surface Electromyography Characteristics for Motion Intention Recognition and Implementation Issues in Lower-limb Exoskeletons

被引:0
作者
Seulki Kyeong
Jirou Feng
Jae Kwan Ryu
Jung Jae Park
Kyeong Ha Lee
Jung Kim
机构
[1] Korea Advanced Institute of Science and Technology (KAIST),Department of Mechanical Engineering
[2] LIG Nex 1,undefined
来源
International Journal of Control, Automation and Systems | 2022年 / 20卷
关键词
Disturbance force; exoskeleton; surface electromyography (sEMG); walking environment;
D O I
暂无
中图分类号
学科分类号
摘要
Recognizing the user’s motion intentions is a crucial challenge to develop human augmented robotic devices due to safety and easiness of interactions. Among the possible sensorial modalities, surface electromyography (sEMG) signals have been tested to be a primary motion intention channel due to the inherent advantage of electromechanical delay and the muscle activation information. However, the lack of detailed sEMG characteristics as motion recognition has been difficult issues to develop safe and intuitive interactions with the robots. In this study, we evaluated the sEMG characteristics for their potential applicability to recognizing the motion intentions of humans. For the discrete motion intention recognition, the walking environments were classified using only sEMG signals by support vector machine (SVM) and linear discriminated analysis (LDA) models with accuracy of 79.1% and 76.3%. Due to the fact that it is crucial to identify an unexpected disturbance by the collision between the exoskeleton and surrounding environment in recognizing the user intention to guarantee the safety of the user, sEMG and torque sensors were used to classify user-intended interaction forces and disturbance forces in the event of collisions. A control algorithm was proposed that detects and compensates for collisions, and its performance showed that robust motion intention recognition and control of powered exoskeletons are possible. We investigated the effect of muscle fatigue caused by long-term walking with heavy load wearing an exoskeleton. The sEMG amplitude and frequency were analyzed for muscle fatigue due to single-joint (knee extensions) and multi-joint (walking) exercises, and muscle fatigue due to walking was prominent in the signal from the vastus medialis (VM). The characteristics of sEMG due to muscle fatigue should be seriously considered in continuous motion estimation.
引用
收藏
页码:1018 / 1028
页数:10
相关论文
共 143 条
  • [1] Dollar A M(2008)Lower extremity exoskeletons and active orthoses: Challenges and state-of-the-art IEEE Transactions on Robotics 24 144-158
  • [2] Herr H(2017)Lower-limb exoskeletons: Research trends and regulatory guidelines in medical and non-medical applications International Journal of Advanced Robotic Systems 14 1-27
  • [3] Rupal B S(2013)Developing a multi-joint upper limb exoskeleton robot for diagnosis, therapy, and outcome evaluation in neurorehabilitation IEEE Transactions on Neural Systems and Rehabilitation Engineering 21 490-499
  • [4] Rafique S(2015)Three-stage design analysis and multicriteria optimization of a parallel ankle rehabilitation robot using genetic algorithm IEEE Transactions on Automation Science and Engineering 12 1433-1446
  • [5] Singla A(2013)Rehabilitation exoskeleton design: Exploring the effect of the anterior lunge degree of freedom IEEE Transactions on Robotics 29 838-846
  • [6] Singla E(2018)Design and experimental verification of hip exoskeleton with balance capacities for walking assistance IEEE/ASME Transactions on Mechatronics 23 274-285
  • [7] Isaksson M(2019)An elbow exoskeleton for upper Limb rehabilitation with series elastic actuator and cable-driven differential IEEE Transactions on Robotics 35 1464-1474
  • [8] Virk G S(2020)Development of a soft exosuit system for walking assistance during stair ascent and descent International Journal of Control, Automation, and Systems 18 2678-2686
  • [9] Ren Y(2015)Review of assistive strategies in powered lower-limb orthoses and exoskeletons Robotics and Autonomous Systems 64 120-136
  • [10] Kang S H(2019)sEMG based human motion intention recognition Journal of Robotics 2019 3679174-2175