A Weak Signal Extraction Method for Human Blood Glucose Noninvasive Measurement using Near Infrared Spectroscopy

被引:0
作者
Li-Na Li
Qing-Bo Li
Guang-Jun Zhang
机构
[1] Key Laboratory of Education Ministry,School of Instrumentation Science and Opto
来源
Journal of Infrared, Millimeter, and Terahertz Waves | 2009年 / 30卷
关键词
Uninformative variable elimination; Successive projections algorithm; Blood glucose noninvasive measurement; Near infrared spectroscopy;
D O I
暂无
中图分类号
学科分类号
摘要
Background interference from optical absorption of matrix components, low spectral selectivity and low spectral sensitivity are the main interference factors for human blood glucose noninvasive measurement using near infrared (NIR) spectroscopy. In order to extract the weak glucose concentration information, a modified uninformative variable elimination (mUVE) method combined with successive projections algorithm (SPA) named as mUVE-SPA, is proposed. mUVE is used to eliminate matrix background and high-frequency noise by wavelet multi-resolution technology. SPA is followed to select variables with minimum colinearity by projection algorithm in a vector space. The proposed method was applied in two NIR spectra data sets (plasma samples experiment in vitro and human blood glucose noninvasive measurement experiment in vivo) respectively. The performance and adaptability of the proposed strategy were discussed. The results indicate that the proposed hybrid method can give an alternative path to extract weak glucose information and yield more parsimonious models with higher precision.
引用
收藏
页码:1191 / 1204
页数:13
相关论文
共 50 条
[31]   Noninvasive Human Triglyceride Detecting with Near-Infrared Spectroscopy [J].
Yuan Jing-ze ;
Lu Qi-peng ;
Wu Chun-yang ;
Ding Hai-quan ;
Gao Hong-zhi ;
Li Wan-xia ;
Wang Yang .
SPECTROSCOPY AND SPECTRAL ANALYSIS, 2018, 38 (01) :42-48
[32]   Noninvasive Measurement of Serum Bilirubin Employing Near-Infrared Spectroscopy [J].
Li Gang ;
Li Zhe ;
Wang Meng-Jun ;
Lin Ling ;
Zhang Bao-Ju .
CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2013, 41 (02) :263-267
[33]   Noninvasive measurement of cerebral hemoglobin oxygen saturation using two near infrared spectroscopy approaches [J].
Quaresima, V ;
Sacco, S ;
Totaro, R ;
Ferrari, M .
JOURNAL OF BIOMEDICAL OPTICS, 2000, 5 (02) :201-205
[34]   A Noninvasive Accurate Measurement of Blood Glucose Levels with Raman Spectroscopy of Blood in Microvessels [J].
Li, Nan ;
Zang, Hang ;
Sun, Huimin ;
Jiao, Xianzhi ;
Wang, Kangkang ;
Liu, Timon Cheng-Yi ;
Meng, Yaoyong .
MOLECULES, 2019, 24 (08)
[35]   Non-invasive Blood Glucose Measurement Scheme Based on Near-infrared Spectroscopy [J].
Wang Shulei ;
Yuan Xueguang ;
Zhang Yangan .
2017 CONFERENCE ON LASERS AND ELECTRO-OPTICS PACIFIC RIM (CLEO-PR), 2017,
[36]   Application of genetic algorithms in fundamental study of non-invasive measurement of human blood glucose concentration with near infrared spectroscopy [J].
Wang, H ;
Li, QB ;
Liu, ZY ;
Xu, KX .
CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2002, 30 (07) :779-783
[37]   Macrostickies measurement by an automated method using laser triangulation and near infrared spectroscopy [J].
Huber, Patrick ;
Borel, Pascal ;
Soysouvanh, Davy ;
Ossard, Sylvie ;
Delagoutte, Thierry .
NORDIC PULP & PAPER RESEARCH JOURNAL, 2015, 30 (02) :234-242
[38]   Measurement of glucose and other analytes in undiluted human serum with near-infrared transmission spectroscopy [J].
Hazen, KH ;
Arnold, MA ;
Small, GW .
ANALYTICA CHIMICA ACTA, 1998, 371 (2-3) :255-267
[39]   Noninvasive Cellular Oxygenation Measurement During Graded Hypoxia Using Visible-Near-Infrared Spectroscopy [J].
Arakaki, Lorilee S. L. ;
Ciesielski, Wayne A. ;
McMullan, D. Michael ;
Schenkman, Kenneth A. .
APPLIED SPECTROSCOPY, 2020, 74 (10) :1263-1273
[40]   Application of Two-Dimensional Near-Infrared Correlation Spectroscopy in the Specificity Analysis of Noninvasive Blood Glucose Sensing [J].
Hu Yong-xiang ;
Liu Rong ;
Zhang Wen ;
Xu Ke-xin .
SPECTROSCOPY AND SPECTRAL ANALYSIS, 2017, 37 (02) :491-496