Non-invasive Angiographic-based Fractional Flow Reserve: Technical Development, Clinical Implications, and Future Perspectives

被引:0
作者
Joyce Peper
Michiel L. Bots
Tim Leiner
Martin J. Swaans
机构
[1] St. Antonius Hospital,Department of Cardiology
[2] University Medical Center Utrecht,Department of Radiology
[3] University Medical Center Utrecht,Julius Center for Health Sciences and Primary Care
来源
Current Medical Science | 2023年 / 43卷
关键词
coronary artery disease; quantitative flow ratio; fractional flow reserve; diagnostic accuracy; physiology guided percutaneous coronary intervention;
D O I
暂无
中图分类号
学科分类号
摘要
New non- and less-invasive techniques have been developed to overcome the procedural and operator related burden of the fractional flow reserve (FFR) for the assessment of potentially significant stenosis in the coronary arteries. Virtual FFR-techniques can obviate the need for the additional flow or pressure wires as used for FFR measurements. This review provides an overview of the developments and validation of the virtual FFR-algorithms, states the challenges, discusses the upcoming clinical trials, and postulates the future role of virtual FFR in the clinical practice.
引用
收藏
页码:423 / 433
页数:10
相关论文
共 117 条
  • [31] Morris PD(2016)Visual-Functional Mismatch Between Coronary Angiography and Fractional Flow Reserve Int J Angiol 25 229-10
  • [32] Ryan D(2021)Angiographic quantitative flow ratio-guided coronary intervention (FAVOR III China): a multicentre, randomised, sham-controlled trial Lancet 398 2149-73
  • [33] Morton AC(2018)Diagnostic Accuracy of Quantitative Flow Ratio for Assessing Myocardial Ischemia in Prior Myocardial Infarction Circ J 82 807-753
  • [34] Papafaklis MI(2018)Quantitative Flow Ratio Identifies Nonculprit Coronary Lesions Requiring Revascularization in Patients with ST-Segment-Elevation Myocardial Infarction and Mu-ltivessel Disease Circ Cardiovasc Interv 11 1-1728
  • [35] Muramatsu T(2022)Performance of quantitative flow ratio in patients with aortic stenosis undergoing transcatheter aortic valve implantation Catheter Cardiovasc Interv 99 68-245
  • [36] Ishibashi Y(2018)Influence of Microcirculatory Dysfunction on Angiography-Based Functional Assessment of Coronary Stenoses JACC Cardiovasc Interv 11 741-157
  • [37] Tu S(2019)Comparison of Diagnostic Performance of Quantitative Flow Ratio in Patients With Versus Without Diabetes Mellitus Am J Cardiol 123 1722-undefined
  • [38] Barbato E(2015)Severity of morphological lesion complexity affects fractional flow reserve in intermediate coronary stenosis J Cardiol 66 239-undefined
  • [39] Köszegi Z(2013)Virtual Fractional Flow Reserve From Coronary Angiography: Modeling the Significance of Coronary Lesions JACC Cardiovasc Interv 6 149-undefined
  • [40] Tu S(undefined)undefined undefined undefined undefined-undefined