Comparison of invasive and non-invasive blood pressure monitoring during clinical anaesthesia in dogs

被引:0
作者
Paul D. MacFarlane
Nicola Grint
Alexandra Dugdale
机构
[1] University of Liverpool,Department of Clinical Veterinary Medicine
来源
Veterinary Research Communications | 2010年 / 34卷
关键词
Anaesthesia; Blood pressure; Clinical; Dogs; Non-invasive;
D O I
暂无
中图分类号
学科分类号
摘要
Monitoring blood pressure during anaesthesia is widely recommended in man and animals. The accuracy of any device used to measure blood pressure is an important consideration when selecting monitoring equipment, the ANSI/AAMI SP10 standard is widely cited in this respect in recent veterinary publications. Blood pressure was monitored using invasive and non-invasive techniques during clinical anaesthesia in 19 dogs. The results were compared using Bland-Altman analysis. The bias (and limits of agreement) between invasive and non-invasive measurement was 7.1 mmHg (+/−34.7) for systolic blood pressure, −1.8 mmHg (+/−27.4) for mean blood pressure and 6.9 mmHg (+/−27.5) for diastolic blood pressure. In a clinical setting the bias between invasive and non-invasive measurement techniques was similar or smaller than laboratory reports, however the limits of agreement were considerably wider suggesting that care should be exercised when interpreting NIBP values.
引用
收藏
页码:217 / 227
页数:10
相关论文
共 65 条
[1]  
Binns SH(1995)American College of Veterinary Anesthesiology Suggestions for monitoring anesthetized veterinary patients J Am Vet Med Assoc 206 936-937
[2]  
Sisson DD(1995)Doppler ultrasonographic, oscillometric sphygmomanometric, and photoplethysymographic techniques for non-invasive blood pressure measurement in anesthetized cats J Vet Int Med 9 405-414
[3]  
Buoscio DA(1986)Statistical methods for assessing agreement between two methods for clinical measurement Lancet 327 307-310
[4]  
Bland JM(1996)Epidemiological study of blood pressure in domestic dogs J Small Anim Pract 37 116-125
[5]  
Altman DG(1996)Comparison of direct and indirect (oscillometric) measurements of arterial blood pressure in conscious dogs Res Vet Sci 61 17-21
[6]  
Bodey AR(2007)Comparison of Doppler oscillometric, and direct arterial blood pressure in dogs during normotension, hypotension, and hypertension J Vet Emerg Crit Care 17 1-12
[7]  
Michell AR(1997)Evaluation of an oscillometric blood pressure monitor on anesthetized cats and the effect of cuff placement and fur on accuracy Vet Surg 26 347-353
[8]  
Bodey AR(2008)Results of the confidential enquiry into perioperative small animal fatalities regarding risk factors for anesthetic-related deaths in dogs J Am Vet Med Assoc 233 1096-1104
[9]  
Michell AR(2008)Clinical evaluation of the surgivet V60046, a non invasive blood pressure monitor in anaesthetized dogs Vet Anaesth Analg 35 13-21
[10]  
Bovee KC(1995)Comparison of direct and indirect blood pressure measurements in anesthetized dogs Can J Vet Res 59 238-240