Determination of Arsenic in Dolomites with a Simple Field Spectrometric Device

被引:0
作者
Katarzyna Stec
Andrzej Bobrowski
Kurt Kalcher
Helmut Moderegger
Walter Goessler
机构
[1] Institute of Refractory Materials,Department of Building Materials Technology, Faculty of Materials Science and Ceramics
[2] AGH – University of Science and Technology,undefined
[3] Institute of Chemistry,undefined
[4] Analytical Chemistry,undefined
[5] Karl-Franzens University,undefined
来源
Microchimica Acta | 2006年 / 153卷
关键词
Key words: Arsenic; dolomite samples; hydride generation; spectrophotometry; ICP-OES; ICP-MS; field device; SupraLab.;
D O I
暂无
中图分类号
学科分类号
摘要
A simple and an inexpensive procedure for the determination of total arsenic in dolomites is proposed. The method applies the spectrometric field device Supralab SD which was initially designed for the determination of arsenic in drinking water. The method relies on the formation of the volatile AsH3 and its reaction with mercuric bromide, immobilized in a membrane, to yield a yellowish-brown reaction product, which is spectrophotometrically detected. The dolomite samples were rapidly dissolved in hot hydrochloric acid in an open vessel and then were analyzed with the portable instrument. The 3 s detection limit of the developed method was 0.1 µg L−1 as in the solution containing dissolved dolomites. The time of As determination in the solution did not exceed 5 min.
引用
收藏
页码:45 / 49
页数:4
相关论文
共 50 条
  • [21] Electrothermal atomic absorption spectrometric determination of arsenic in essential lavender and rose oils
    Karadjova, IB
    Lampugnani, L
    Tsalev, DL
    TALANTA, 2005, 65 (04) : 1015 - 1021
  • [22] COMPARISON OF INORGANIC INTERFERENCES IN ATOMIC-ABSORPTION SPECTROMETRIC DETERMINATION OF ARSENIC AND SELENIUM
    PIERCE, FD
    BROWN, HR
    ANALYTICAL CHEMISTRY, 1977, 49 (09) : 1417 - 1422
  • [23] Sequential injection vapor generation atomic absorption spectrometric determination of mercury and arsenic
    Ma, HB
    Xu, SK
    Zhou, HY
    Wang, SL
    Fang, ZL
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2000, 20 (04) : 529 - 532
  • [24] Simple and sensitive determination of arsenic by volatile arsenic trichloride generation atomic fluorescence spectrometry
    Li, Xiaohong
    Su, Yingying
    Xu, Kailai
    Hou, Xiandeng
    Lv, Yi
    TALANTA, 2007, 72 (05) : 1728 - 1732
  • [26] A SIMPLE DEVICE FOR POSITION DETERMINATION DURING MYELOGRAPHY
    GREENBERG, IM
    JOURNAL OF NEUROSURGERY, 1952, 9 (01) : 108 - 110
  • [27] A SIMPLE DEVICE FOR THE DETERMINATION OF SPHERICITY FACTOR - COMMENT
    BEECKMANS, JM
    INDUSTRIAL & ENGINEERING CHEMISTRY FUNDAMENTALS, 1982, 21 (01): : 97 - 97
  • [28] SIMPLE DEVICE FOR DETERMINATION OF SOLUBILITY OF GASES IN LIQUIDS
    JANOVSKY, I
    CHEMICKE LISTY, 1971, 65 (08): : 857 - &
  • [29] A Portable Microplasma Optical Emission Spectrometric Device with Online Digestion Function for Field and Sensitive Determination of Lead in Biological Samples
    Cai, Ji-Ying
    Zhang, Xiao
    Wei, Yu-Jia
    Chen, Shuai
    Yu, Yong-Liang
    Wang, Jian-Hua
    ANALYTICAL CHEMISTRY, 2024, 96 (09) : 3733 - 3738
  • [30] A SIMPLE DEVICE FOR FIELD STUDIES OF ANIMAL ACTIVITY
    STEBBINS, L
    DAISLEY, D
    CANADIAN JOURNAL OF ZOOLOGY-REVUE CANADIENNE DE ZOOLOGIE, 1983, 61 (06): : 1401 - 1404