Graphene and graphene nanohybrid composites-based electrodes for physiological sensing applications

被引:0
作者
Bani Gandhi
Nallanthighal Srinivasa Raghava
机构
[1] Delhi Technological University (DTU),Department of Electronics and Communication Engineering
来源
Biomedical Microdevices | 2022年 / 24卷
关键词
Graphene; MWCNT-COOH; SWCNT-COOH; PDMS; Electrocardiogram (ECG); Internet-of-Things (IoT);
D O I
暂无
中图分类号
学科分类号
摘要
In this paper, three categories of ECG electrodes were fabricated. Graphene/PDMS(Polydimethylsiloxane)(G-I), Graphene/MWCNT-COOH(Carboxylic-acid functionalized Multi-walled Carbon Nanotubes)/PDMS(G-II),and Graphene/SWCNT-COOH(Carboxylic-acid functionalized Single-walled Carbon Nanotubes)/PDMS(G-III). Each group had thirteen electrodes with varying concentrations ranging from 0.1-5wt%. Since CNTs get tangled easily, it becomes necessary to disperse them properly. To achieve optimal dispersion, CNTs were first sonicated with Isopropyl Alcohol (IPA), and then with PDMS. Mold casting was the technique used for fabricating the electrodes. The results were compared with the conventional ECG electrodes. Best results were achieved from G-III at 3wt% as the value of capacitance is high (0.172nF) as compared to G-I and G-III values at 3wt% which are 0.036nF (0.036nF) and 0.015nF respectively. As capacitance has an inverse relationship with the resistance and impedance, thus at 3wt% the resistance (0.361MΩ) and impedance (0.36MΩ) values are low, which satisfies the relationship. The values of resistance and impedance of G-II are low when compared with the values of G-I and G-II. Great results and ECG waveform are achieved with 3wt% for G-II, which also uses less nanomaterials to produce such great ECG results. It was observed that even after using the electrodes for 5 days, the ECG signal did not degrade over time and no skin allergies were detected for any of the three groups. The ECG tracking system was developed on the concept of the Internet-of-Things (IoT) using various electronic hardware components and software solutions. The results from the fabricated electrodes were promising and were suitable for long-term, and continuous ECG monitoring.
引用
收藏
相关论文
共 53 条
  • [1] Baek JY(2008)Flexible polymeric dry electrodes for the long-term monitoring of ECG Sens. Actuators. a. Phys. 143 423-429
  • [2] An JH(2020)Fabrication Techniques for Carbon Nanotubes Based ECG Electrodes: A Review IETE. J. Res. 10 325-1479
  • [3] Choi JM(2019)Paper-Based Flexible Electrode Using Chemically-Modified Graphene and Functionalized Multiwalled Carbon Nanotube Composites for Electrophysiological Signal Sensing Information 59 1472-11
  • [4] Park KS(2012)CNT/PDMS composite flexible dry electrodes for long-term ECG monitoring IEEE. Trans. Biomed. Eng. 8 1-4774
  • [5] Lee SH(2018)Simple and cost-effective method of highly conductive and elastic carbon nanotube/ polydimethylsiloxane composite for wearable electronics Sci. Rep. 10 4770-7
  • [6] Gandhi B(2016)Bioinspired, Highly Stretchable, and Conductive Dry Adhesives Based on 1D–2D Hybrid Carbon Nanocomposites for All-in-One ECG Electrodes ACS Nano 26 1-1300
  • [7] Raghava NS(2015)Self-adhesive epidermal carbon nanotube electronics for tether-free long-term continuous recording of biosignals Sci. Rep. 79 1297-109935
  • [8] Hossain MF(2015)A novel method of fabricating carbon nanotubes polydimethylsiloxane composite electrodes for electrocardiography Biomater. Sci. Polym. e. 6 109916-155
  • [9] Heo JS(1997)Elastic properties of carbon nanotubes and nanoropes Phys. Rev. Lett. 251 148-12
  • [10] Nelson J(2016)Surface functionalization of carbon nanotubes: fabrication and applications RSC. Adv. 40 1-640