Fluorescent biosensor for the detection of hyaluronidase: intensity-based ratiometric sensing and fluorescence lifetime-based sensing using a long lifetime azadioxatriangulenium (ADOTA) fluorophore

被引:0
|
作者
Rahul Chib
Mark Mummert
Ilkay Bora
Bo W. Laursen
Sunil Shah
Robert Pendry
Ignacy Gryczynski
Julian Borejdo
Zygmunt Gryczynski
Rafal Fudala
机构
[1] University of North Texas Health Science Center,Department of Cell Biology, Immunology and Microbiology, Center for Fluorescence Technologies and Nanomedicine
[2] University of North Texas Health Science Center,Mental Sciences Institute
[3] University of Copenhagen,Nano
[4] Texas Christian University,Science Center & Department of Chemistry
来源
关键词
Hyaluronidase sensing; Azadioxatriangulenium fluorophore; Ratiometric sensing; Fluorescence lifetime-based sensing; Fluorescence-based assay;
D O I
暂无
中图分类号
学科分类号
摘要
In this report, we have designed a rapid and sensitive, intensity-based ratiometric sensing as well as lifetime-based sensing probe for the detection of hyaluronidase activity. Hyaluronidase expression is known to be upregulated in various pathological conditions. We have developed a fluorescent probe by heavy labeling of hyaluronic acid with a new orange/red-emitting organic azadioxatriangulenium (ADOTA) fluorophore, which exhibits a long fluorescence lifetime (∼20 ns). The ADOTA fluorophore in water has a peak fluorescence lifetime of ∼20 ns and emission spectra centered at 560 nm. The heavily ADOTA-labeled hyaluronic acid (HA-ADOTA) shows a red shift in the peak emission wavelength (605 nm), a weak fluorescence signal, and a shorter fluorescence lifetime (∼4 ns) due to efficient self-quenching and formation of aggregates. In the presence of hyaluronidase, the brightness and fluorescence lifetime of the sample increase with a blue shift in the peak emission to its original wavelength at 560 nm. The ratio of the fluorescence intensity of the HA-ADOTA probe at 560 and 605 nm can be used as the sensing method for the detection of hyaluronidase. The cleavage of the hyaluronic acid macromolecule reduces the energy migration between ADOTA molecules, as well as the degree of self-quenching and aggregation. This probe can be efficiently used for both intensity-based ratiometric sensing as well as fluorescence lifetime-based sensing of hyaluronidase. The proposed method makes it a rapid and sensitive assay, useful for analyzing levels of hyaluronidase in relevant clinical samples like urine or plasma.
引用
收藏
页码:3811 / 3821
页数:10
相关论文
共 50 条
  • [21] Phase-sensitive flow cytometry: fluorescence lifetime-based sensing technology for analyzing free fluorophore and cells/particles labeled with fluorescent probes
    Steinkamp, JA
    ADVANCED MATERIALS AND OPTICAL SYSTEMS FOR CHEMICAL AND BIOLOGICAL DETECTION, 1999, 3858 : 151 - 160
  • [22] Lifetime-based ammonia sensing utilizing fluorescence resonance energy transfer.
    Chang, Q
    Rao, G
    Sipior, J
    Lakowicz, JR
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1996, 211 : 196 - BIOT
  • [23] Fluorescence lifetime-based determination of cyanide using a carbonic anhydrase-based biosensor
    Thompson, RB
    Lin, HJ
    Ge, Z
    Johnson, K
    Fierke, CA
    BIOPHYSICAL JOURNAL, 1997, 72 (02) : THAM6 - THAM6
  • [24] Method for lifetime-based chemical sensing using the demodulation of the luminescence signal
    Andrzejewski, D
    Klimant, I
    Podbielska, H
    SENSORS AND ACTUATORS B-CHEMICAL, 2002, 84 (2-3) : 160 - 166
  • [25] Fluorescence lifetime based pH sensing using resorufin
    Ryder, AG
    Power, S
    Glynn, TJ
    OPTO-IRELAND 2002: OPTICS AND PHOTONICS TECHNOLOGIES AND APPLICATIONS, PTS 1 AND 2, 2003, 4876 : 827 - 835
  • [26] Steam-sterilizable, fluorescence lifetime-based sensing film dissolved carbon dioxide
    Chang, Qing
    Randers-Eichhorn, Lisa
    Lakowicz, Joseph R.
    Rao, Govind
    Biotechnology Progress, 14 (02): : 326 - 331
  • [27] Steam-sterilizable, fluorescence lifetime-based sensing film for dissolved carbon dioxide
    Chang, Q
    Randers-Eichhorn, L
    Lakowicz, JR
    Rao, G
    BIOTECHNOLOGY PROGRESS, 1998, 14 (02) : 326 - 331
  • [28] Fluorescence lifetime-based sensing of pH, Ca2+, K+ and glucose
    Lakowicz, Joseph R.
    Szmacinski, Henryk
    Sensors and Actuators, B: Chemical, 1993, B11 (1-3) : 133 - 143
  • [29] FLUORESCENCE LIFETIME-BASED SENSING OF PH, CA-2(+), K+ AND GLUCOSE
    LAKOWICZ, JR
    SZMACINSKI, H
    SENSORS AND ACTUATORS B-CHEMICAL, 1993, 11 (1-3) : 133 - 143
  • [30] Lifetime-based sensing of glucose using luminescent ruthenium (II) metal complex
    Murtaza, Z
    Lakowicz, JR
    ADVANCES IN FLUORESCENCE SENSING TECHNOLOGY IV, PROCEEDINGS OF, 1999, 3602 : 326 - 334