Intubation using video laryngeal mask airway SaCoVLM and laryngeal mask airway Ambu® Aura-i in anesthetized children with microtia: a randomized controlled study

被引:0
作者
Juan Zhi
Fu-Xia Yan
Ling-Xin Wei
Dong Yang
Xiao-Ming Deng
机构
[1] Chinese Academy of Medical Sciences and Peking Union Medical College,Department of Anesthesiology, Plastic Surgery Hospital
[2] Chinese Academy of Medical Sciences and Peking Union Medical College,Department of Anesthesiology, Fuwai Hospital, National Center for Cardiovascular Diseases
来源
Journal of Clinical Monitoring and Computing | 2023年 / 37卷
关键词
Laryngeal mask-guided tracheal intubation; Airway management; Ambu Aura-i; SaCoVLM;
D O I
暂无
中图分类号
学科分类号
摘要
The Ambu Aura-i laryngeal mask is considered to be a device for blind intubation as well as for fiberoptic guided intubation. The novel video laryngeal airway mask SaCoVLM is a supraglottic airway device that allows intubation under direct vision. We hypothesized that success rates for device placement and tracheal intubation with the SaCoVLM would be comparable with the Ambu Aura-i mask. A prospective, randomized clinical trial was conducted from March 2021 to December 2021. One hundred and twenty patients were enrolled and randomized in the study. Direct intubation was performed with the SaCoVLM, and fiberoptic guided intubation was performed with the Ambu Aura-i mask. The primary outcome measure was the first success rate of LMA placement. Secondary outcome measures were the time from device placement and time from endotracheal intubation (as well as the time for LMA removal after successful intubation), differences in airway leak pressure, fiberoptic grade of the laryngeal view, and incidence of blood staining. The first success rate of LMA placement was similar for the two devices. There was no difference in the time for successful endotracheal intubation between the Ambu Aura-i and SaCoVLM groups (24.1 s ± 6.3 versus 25.7 s ± 2.1; p > 0.05). The time for removal was slower in the SaCoVLM group than in the Ambu Aura-i group (20.8 s ± 0.8 versus 14.7 s ± 6.1; p < 0.01). The airway leak pressure was higher in the SaCoVLM group than in the Ambu Aura-i group (27.0 s ± 1.0 versus 22.3 s ± 3.6; p < 0.01), and the incidence of blood staining was higher in the SaCoVLM group (16.7%). The SaCoVLM has an overall comparable performance to the Ambu Aura-i mask. However, the SaCoVLM is better relative to direct intubation without the assistance of a flexible intubation scope, which reduces the device’s demand.
引用
收藏
页码:857 / 865
页数:8
相关论文
共 68 条
  • [1] Uezono S(2001)Prediction of difficult airway in school-aged patients with microtia Paediatr Anaesth 11 409-13
  • [2] Holzman RS(2020)Prediction of difficult laryngoscopy in school-aged patients with microtia Minerva Anestesiol 86 387-93
  • [3] Goto T(2018)Management of the difficult airway in the pediatric patient J Pediatr Intensive Care 7 115-25
  • [4] Xu J(2011)The difficult airway society ‘ADEPT’ guidance on selecting airway devices: the basis of a strategy for equipment evaluation Anesth 66 726-37
  • [5] Chen K(2020)Comparison of fiberoptic-guided tracheal intubation through intubating laryngeal mask airway (ILMA) FastrachTM and Ambu® Aura-i™: a Randomized Clinical Study Cureus. 12 e10178-34
  • [6] Deng X(2021)Features of new vision-incorporated third-generation video laryngeal mask airways J Clin Monit Comput 32 429-75
  • [7] Wei L(1985)A clinical sign to predict difficult tracheal intubation: a prospective study Can Anaesth Soc J 81 69-70
  • [8] Yang D(1994)What is the best way to determine oropharyngeal classification and mandibular space length to predict difficult laryngoscopy? Anesthesiology 51 1167-44
  • [9] Wang Y(1996)Jaw thrusting as a clinical test to assess the adequate depth of anaesthesia for insertion of the laryngeal mask Anesth 67 139-21
  • [10] Krishna SG(2012)A randomised trial comparing the laryngeal mask airway supreme with the laryngeal mask airway unique in children Anesth 11 319-64