Asynchronous Adaptive Threshold Level Crossing ADC for Wearable ECG Sensors

被引:0
作者
Anita Antony
Shobha Rekh Paulson
D. Jackuline Moni
机构
[1] Karunya Institute of Technology & Sciences,Department of Electronics and Communication Engineering
来源
Journal of Medical Systems | 2019年 / 43卷
关键词
Asynchronous; Adaptive; LC; Level crossing; ADC; Analog to digital converter; ECG; Electrocardiogram; Wearable; Sensors; Low power;
D O I
暂无
中图分类号
学科分类号
摘要
The level crossing ADC generates digitized samples consisting of the magnitude of input signal and time interval between two consecutive level crossings when the input signal crosses the threshold level. This paper presents a new architecture of low power asynchronous adaptive threshold level crossing (LC) ADC suitable for wearable ECG sensors based on a novel algorithm for determining adaptive threshold. The adaptive threshold was determined by calculating the mean of maximum and minimum values of signal in a predetermined window. Polynomial interpolation was used to reconstruct the signal. A signal to noise distortion ratio of 57.50 dB and a mean square error (MSE) measure of 1.368*10−8 V2 was achieved by the proposed algorithm for a 1 mV, 10 Hz input sinusoidal signal in MATLAB. The asynchronous adaptive threshold LC ADC operating from a supply voltage of 0.8 V occupied a layout area of 266.33*331.385 μm2 when implemented in CADENCE virtuoso using 180 nm technology. The designed circuit consumes an average power of 367.6 nW for a 1mVpp, 10 Hz input sinusoidal signal when simulated in Virtuoso.
引用
收藏
相关论文
共 50 条
  • [41] Optimum threshold level of degraded structures based on sensors data
    Elsayed, E. A.
    Zhang, Hao
    TWELFTH ISSAT INTERNATIONAL CONFERENCE RELIABILITY AND QUALITY IN DESIGN, PROCEEDINGS, 2006, : 187 - +
  • [42] A Wearable ECG Monitoring System using Adaptive EMD Filter based on Activity Status
    Kim, Byeong-Hoon
    Noh, Yun-Hong
    Jeong, Do-Un
    2015 IEEE 29TH INTERNATIONAL CONFERENCE ON ADVANCED INFORMATION NETWORKING AND APPLICATIONS WORKSHOPS WAINA 2015, 2015, : 11 - 16
  • [43] 8-bit Nano Watt Level Crossing ADC for Bio-Medical Application
    Polineni, Sreenivasulu
    Gupta, Anil Kumar
    2015 INTERNATIONAL CONFERENCE ON COMPUTER, COMMUNICATION AND CONTROL (IC4), 2015,
  • [44] Wearable Mobile Ear-based ECG Monitoring Device Using Graphene-Coated Sensors
    Celik, Numan
    Balachandran, Wamadeva
    Manivannan, Nadarajah
    Winter, Eva-Maria
    Schnalzer, Bianca
    Burgsteiner, Harald
    2017 IEEE SENSORS, 2017, : 133 - 135
  • [45] Using Wearable ECG/PPG Sensors for Driver Drowsiness Detection Based on Distinguishable Pattern of Recurrence Plots
    Lee, Hyeonjeong
    Lee, Jaewon
    Shin, Miyoung
    ELECTRONICS, 2019, 8 (02)
  • [46] A Power-Efficient Level-Crossing Analog-to-Digital Converter with Adaptive Resolution Based on a Signal-Dependent Sampling Mechanism
    Zanjani, Amirhossein
    Jalali, Mohsen
    CIRCUITS SYSTEMS AND SIGNAL PROCESSING, 2023, 42 (01) : 63 - 83
  • [47] Detection of QRS Complexes in 12-lead ECG using Adaptive Quantized Threshold
    Chouhan, V. S.
    Mehta, S. S.
    INTERNATIONAL JOURNAL OF COMPUTER SCIENCE AND NETWORK SECURITY, 2008, 8 (01): : 155 - 163
  • [48] ECG Motion Artifact Filtering Based on Two-Stage Adaptive Threshold Rules
    Lü, Jian-Hang
    Li, Yu-Rong
    Chen, Jian-Guo
    Gao, Ning
    Tien Tzu Hsueh Pao/Acta Electronica Sinica, 2024, 52 (10): : 3493 - 3506
  • [49] An ECG Recording Front-End With Continuous-Time Level-Crossing Sampling
    Li, Yongjia
    Mansano, Andre L.
    Yuan, Yuan
    Zhao, Duan
    Serdijn, Wouter A.
    IEEE TRANSACTIONS ON BIOMEDICAL CIRCUITS AND SYSTEMS, 2014, 8 (05) : 626 - 635
  • [50] Background offset mismatch and loop delay mismatch calibration for fixed-window level crossing ADC
    Xin, Xin
    Mao, Wen
    Luo, Juyuan
    Song, Mengdi
    Tong, Xingyuan
    AEU-INTERNATIONAL JOURNAL OF ELECTRONICS AND COMMUNICATIONS, 2023, 171