Does prostate configuration affect the efficacy and safety of GreenLight HPS™ laser photoselective vaporization prostatectomy (PVP)?

被引:0
|
作者
Xiao Gu
Kurt Strom
Massimiliano Spaliviero
Carson Wong
机构
[1] The University of Oklahoma Health Sciences Center,Department of Urology
[2] The First Clinical Medical College at Yangzhou University,Department of Urology
[3] SouthWest Urology Inc.,Center for Minimally Invasive and Robotic Surgery
[4] Parma Community General Hospital,undefined
来源
Lasers in Medical Science | 2013年 / 28卷
关键词
Benign prostatic hyperplasia; Clinical outcomes; Lithium triborate (LBO) laser; Photoselective vaporization of the prostate; Prostate configuration;
D O I
暂无
中图分类号
学科分类号
摘要
We evaluate the efficacy and safety of GreenLight HPS™ laser photoselective vaporization prostatectomy (PVP) for the treatment of benign prostatic hyperplasia (BPH) with different prostate configuration. Patients were stratified into two groups: bilobe (group I) and trilobe (group II) BPH. Transurethral PVP was performed using a 120 W GreenLight HPS™ side-firing laser system. American Urological Association Symptom Score (AUASS), Quality of Life (QoL) score, maximum flow rate (Qmax), and postvoid residual (PVR) were measured preoperatively and at 1 and 4 weeks and 3, 6, 12, 18, 24 and 36 months postoperatively. A number of 160 consecutive patients were identified (I: 86, II: 74). Among the preoperative parameters, there were significant differences (p < 0.05) in prostate volume (I: 46.0 ± 19.8; II: 87.5 ± 39.6 ml), Qmax (I: 9.9 ± 3.9; II: 8.7 ± 3.5 ml/sec), PVR (I: 59.2 ± 124.6; II: 97.7 ± 119.1 ml) and PSA (I: 1.4 ± 1.4; II: 3.6 ± 2.6 ng/ml), while AUASS and QoL were similar (p > 0.05). Significant differences (p < 0.05) in laser utilization (I: 9.5 ± 6.6; II: 19.5 ± 11.6 min) and energy usage (I: 63.1 ± 43.9; II: 132.5 ± 81.1 kJ) were noted. Clinical outcomes (AUASS, QoL, Qmax, and PVR) showed immediate and stable improvement from baseline (p < 0.05) within each group, but no significant differences between the two groups were observed during the follow-up period (p > 0.05). The incidences of adverse events were low and similar in both groups. Our experience suggests that BPH configuration has little effect on the efficacy and safety of GreenLight HPS™ laser PVP.
引用
收藏
页码:473 / 478
页数:5
相关论文
共 50 条
  • [31] A systematic review and meta-analysis of efficacy and safety comparing greenlight laser vaporization with transurethral resection of the prostate for benign prostatic hyperplasia with prostate volume less than 80 ml
    Liu, Shangjing
    Liu, Hongquan
    Yao, Huibao
    Sun, Fengze
    Wu, Jitao
    Zhou, Zhongbao
    LASERS IN MEDICAL SCIENCE, 2023, 38 (01)
  • [32] Does prostate size impact upon perioperative outcomes associated with photoselective vaporization of the prostate using the 180W lithium triborate laser?
    West, Kellie E.
    Woo, Henry H.
    UROLOGY ANNALS, 2015, 7 (01) : 17 - 20
  • [33] A systematic review and meta-analysis of efficacy and safety comparing greenlight laser vaporization with transurethral resection of the prostate for benign prostatic hyperplasia with prostate volume less than 80 ml
    Shangjing Liu
    Hongquan Liu
    Huibao Yao
    Fengze Sun
    Jitao Wu
    Zhongbao Zhou
    Lasers in Medical Science, 38
  • [34] 180-W XPS GreenLight laser vaporization for benign prostate hyperplasia: 12-month safety and efficacy results for glands larger than 80 mL
    Altay, Bulent
    Erkurt, Bulent
    Kiremit, Murat Can
    Guzelburc, Vahit
    Boz, Mustafa Yucel
    Albayrak, Selami
    LASERS IN MEDICAL SCIENCE, 2015, 30 (01) : 317 - 323
  • [35] 180-W XPS GreenLight laser vaporization for benign prostate hyperplasia: 12-month safety and efficacy results for glands larger than 80 mL
    Bulent Altay
    Bulent Erkurt
    Murat Can Kiremit
    Vahit Guzelburc
    Mustafa Yucel Boz
    Selami Albayrak
    Lasers in Medical Science, 2015, 30 : 317 - 323
  • [36] CHANGES OF SEXUAL FUNCTION AFTER PHOTOSELECTIVE VAPORIZATION OF THE PROSTATE BY 120W GREENLIGHT HIGH PERFORMANCE SYSTEM LASER: LONG-TERM FOLLOW-UP
    Son, Hwancheol
    Park, Juhyun
    Jeong, Seung-hwan
    Cho, Sung Yong
    JOURNAL OF SEXUAL MEDICINE, 2015, 12 : 356 - 356
  • [37] Laser transurethral resection of the prostate: Safety study of a novel system of photoselective vaporization with high power diode laser in prostates larger than 80 mL
    Andres, G.
    Arance, I.
    Gimbernat, H.
    Redondo, C.
    Garcia-Tello, A.
    Angulo, J. C.
    ACTAS UROLOGICAS ESPANOLAS, 2015, 39 (06): : 375 - 382
  • [38] Safety and efficacy of 120w high performance system greenlight laser vaporization for non-muscle-invasive bladder cancer
    Tao, Wei
    Yang, Dongrong
    Shan, Yuxi
    Xue, Boxin
    Sun, Chuanyang
    Zang, Yangchen
    Zhang, Yuanyuan
    JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY, 2013, 21 (02) : 309 - 316
  • [39] GreenLight HPS laser 120 W vs diode laser 300 W vaporization of the prostate for the treatment of benign prostatic hyperplasia in Japanese patients: A prospective, single-center, randomized clinical trial
    Kobayashi, Takeshi
    Seki, Narihito
    Song, Yoo H.
    Dejima, Takashi
    LUTS-LOWER URINARY TRACT SYMPTOMS, 2021, 13 (01) : 31 - 37
  • [40] The Comparison Study of Anatomic Vapor-incision Technique (AVIT) Using the 180W-XPS Greenlight Laser and Photoselective Vaporization of the Prostate for the Treatment of Benign Prostatic Hyperplasia br
    Tao, Wei
    Xu, Ming
    Hu, Guangmo
    Sun, Chuanyang
    Xue, Boxin
    UROLOGY, 2022, 167 : 191 - 197