Navigation surgery for intraoperative sentinel lymph node detection using Indocyanine green (ICG) fluorescence real-time imaging in breast cancer

被引:0
作者
U. Toh
N. Iwakuma
M. Mishima
M. Okabe
S. Nakagawa
Y. Akagi
机构
[1] Kurume University School of Medicine,Department of Surgery
来源
Breast Cancer Research and Treatment | 2015年 / 153卷
关键词
Breast cancer; Sentinel lymph node; Indocyanine green (ICG); Near-infrared fluorescence;
D O I
暂无
中图分类号
学科分类号
摘要
A new sensitive fluorescence imaging system was developed for the real-time identification of sentinel lymph nodes (SLNs) in patients with early breast cancer. The purpose of this study was to evaluate the utility of a color charge-coupled device camera system for the intraoperative detection of SLNs and to determine its clinical efficacy and sensitivity in patients with operable breast cancer. We assessed a total of 168 patients diagnosed with or suspected of having early-stage breast cancer without metastasis in SLNs. The intraoperative detection of SLNs was performed using the conventional Indigo Carmine dye (indigotindisulfonate sodium) technique combined with a new Indocyanine green (ICG) imaging system (HyperEye Medical System: HEMS, MIZUHO IKAKOGYO, Japan) to map SLNs, in which the lymphatic vessels and SLNs were visualized transcutaneously with illuminating ICG fluorescence. Between January 2012 and May 2013, SLNs were successfully identified in all 168 patients (detection rate: 100 %). By histopathology, the sensitivity was 93.8 % for the detection of the metastatic involvement of SLNs (15 of 16 nodal-positive patients). After a median follow-up of 30.5 months, none of the patients presented with axillary recurrence. These results suggest that the HEMS imaging system is a feasible and effective method for the detection of SLNs in breast cancer. Furthermore, the HEMS device permitted the transcutaneous visualization of lymphatic vessels under light conditions, thus facilitating the identification and detection of SLNs without affecting the surgical procedure, together with a high sensitivity and specificity.
引用
收藏
页码:337 / 344
页数:7
相关论文
共 107 条
[21]  
Cody HS(2008)Imaging of lymph flow in breast cancer patients after microdose administration of a near-infrared fluorophore: feasibility study Radiology 246 734-1294
[22]  
De Gournay E(2009)Sentinel lymph node biopsy in breast cancer guided by indocyanine green fluorescence Br J Surg 96 1289-14
[23]  
Guyomard A(1999)Will the true sentinel node please stand? Ann Surg Oncol 6 12-398
[24]  
Coutant C(1994)Lymphatic mapping and sentinel lymphadenectomy for breast cancer Ann Surg 220 391-276
[25]  
Ram R(1997)Histopathologic validation of the sentinel lymph node hypothesis for breast carcinoma Ann Surg 226 271-7720
[26]  
Singh J(2005)American Society of Clinical Oncology guideline recommendations for sentinel lymph node biopsy in early-stage breast cancer J Clin Oncol 23 7703-518
[27]  
McCaig E(2013)Image-guided cancer surgery using near-infrared fluorescence Nat Rev Clin Oncol 10 507-332
[28]  
Verbelen H(2011)The clinical use of indocyanine green as a near-infrared fluorescent contrast agent for image-guided oncologic surgery J Surg Oncol 104 323-154
[29]  
Gebruers N(2009)Preliminary experience for the evaluation of the intraoperative graft patency with real color charge-coupled device camera system: an advanced device for simultaneous capturing of color and near-infrared images during coronary artery bypass graft Interact Cardiovasc Thorac Surg 9 150-77
[30]  
Eeckhout FM(2010)New device for intraoperative graft assessment: HyperEye charge-coupled device camera system Gen Thorac Cardiovasc Surg 58 68-2952