Monitoring reduced scattering coefficient in pedicle screw insertion trajectory using near-infrared spectroscopy

被引:0
作者
Weitao Li
Yangyang Liu
Haixiang Sun
Yue Pan
Zhiyu Qian
机构
[1] Nanjing University of Aeronautics and Astronautics,Department of Biomedical Engineering
来源
Medical & Biological Engineering & Computing | 2016年 / 54卷
关键词
Pedicle screw; Spectroscopy; Near-infrared; Reduced scattering coefficient;
D O I
暂无
中图分类号
学科分类号
摘要
Pedicle screw (PS) implantation is an ideal treatment for severe multilevel vertebra instabilities. The accuracy of fixating PS is a key factor of spinal surgery. We developed a near-infrared spectroscopy device with a needlelike optical fiber probe to monitor optical parameters (reduced scattering coefficient) of vertebra models in real time. The fresh-frozen cadaver, cats and porcine vertebras were first studied in the experiments. Moreover, the reduced scattering coefficient (μ′s) along the different trajectories of PS insertion was obtained. In the fresh-frozen cadavera experiment, μ′s values could be used to distinguish the different compositions of the thoracic vertebra. In cat vertebra experiment, μ′s values of vertebrae bones, including cortical bone (15.30 ± 0.18 cm−1), cancellous bone (7.84 ± 1.11 cm−1) and spinal cord (19.46 ± 0.21 cm−1), were different in vivo. In the pig vertebrae experiment, there were obvious differences between the normal and abnormal PS puncture curves based on μ′s values. Thus, μ′s values measured by using the proposed device could be used as the pattern factor in spinal fusion surgery. Our studies demonstrate that near-infrared spectroscopy method may be potentially used for assisting the PS insertion.
引用
收藏
页码:1533 / 1539
页数:6
相关论文
共 148 条
  • [1] Abumi K(2000)Complications of pedicle screw fixation in reconstructive surgery of the cervical spine Spine 25 962-969
  • [2] Shono Y(2005)Tomographic bioluminescence imaging by use of a combined optical-PET (OPET) system: a computer simulation feasibility study Phys Med Biol 50 4225-4241
  • [3] Ito M(2006)A preliminary study of reliability of impedance measurement to detect iatrogenic initial pedicle perforation (in the porcine model) Eur Spine J 15 316-320
  • [4] Taneichi H(2007)Electrical conductivity measurement: a new technique to detect iatrogenic initial pedicle perforation Eur Spine J 16 1919-1924
  • [5] Kotani Y(1998)Fiber-optic bundle design for quantitative fluorescence measurement from tissue Appl Opt 37 7429-7436
  • [6] Kaneda K(2008)In vivo detection of reduced scattering coefficient of C6 glioma in rat brain tissue by near-infrared spectroscopy J Biomed Opt 13 044003-343
  • [7] Alexandrakis G(2013)Treatment of lumbar instability by posterior interbody cage fusion and transpedicular fixation Egypt Orthop J 48 339-1898
  • [8] Rannou FR(2011)Prospective study of the effect of pedicle screw placement on development of the immature vertebra in an in vivo porcine mode Eur Spine J 20 1892-2550
  • [9] Chatziioannou AF(1997)Continuous electromyographic monitoring to detect nerve root injury during thoracolumbar scoliosis surgery Spine 22 2547-1898
  • [10] Bolger C(2011)Neurosensory tissue morphology with intraoperative optical fiber probe in aqueous medium Optik 122 1895-465