Heart patient health monitoring system using invasive and non-invasive measurement

被引:0
|
作者
Mastoi, Qurat-ul-Ain [1 ]
Alqahtani, Ali [2 ]
Almakdi, Sultan [3 ]
Sulaiman, Adel [3 ]
Rajab, Adel [3 ]
Shaikh, Asadullah [4 ]
Alqhtani, Samar M. [4 ]
机构
[1] Univ West England, Sch Comp Sci & Creat Technol, Bristol BS1 6QY, England
[2] Najran Univ, Coll Comp Sci & Informat Syst, Dept Networks & Commun Engn, Najran 61441, Saudi Arabia
[3] Najran Univ, Coll Comp Sci & Informat Syst, Dept Comp Sci, Najran 61441, Saudi Arabia
[4] Najran Univ, Coll Comp Sci & Informat Syst, Dept Informat Syst, Najran 61441, Saudi Arabia
来源
SCIENTIFIC REPORTS | 2024年 / 14卷 / 01期
关键词
ARRHYTHMIA RECOGNITION; INFORMATION ENTROPY; ECG; CLASSIFICATION; KNN; REGRESSION; MORPHOLOGY; SELECTION; INTERVAL; DISEASE;
D O I
10.1038/s41598-024-60500-0
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
The abnormal heart conduction, known as arrhythmia, can contribute to cardiac diseases that carry the risk of fatal consequences. Healthcare professionals typically use electrocardiogram (ECG) signals and certain preliminary tests to identify abnormal patterns in a patient's cardiac activity. To assess the overall cardiac health condition, cardiac specialists monitor these activities separately. This procedure may be arduous and time-intensive, potentially impacting the patient's well-being. This study automates and introduces a novel solution for predicting the cardiac health conditions, specifically identifying cardiac morbidity and arrhythmia in patients by using invasive and non-invasive measurements. The experimental analyses conducted in medical studies entail extremely sensitive data and any partial or biased diagnoses in this field are deemed unacceptable. Therefore, this research aims to introduce a new concept of determining the uncertainty level of machine learning algorithms using information entropy. To assess the effectiveness of machine learning algorithms information entropy can be considered as a unique performance evaluator of the machine learning algorithm which is not selected previously any studies within the realm of bio-computational research. This experiment was conducted on arrhythmia and heart disease datasets collected from Massachusetts Institute of Technology-Berth Israel Hospital-arrhythmia (DB-1) and Cleveland Heart Disease (DB-2), respectively. Our framework consists of four significant steps: 1) Data acquisition, 2) Feature preprocessing approach, 3) Implementation of learning algorithms, and 4) Information Entropy. The results demonstrate the average performance in terms of accuracy achieved by the classification algorithms: Neural Network (NN) achieved 99.74%, K-Nearest Neighbor (KNN) 98.98%, Support Vector Machine (SVM) 99.37%, Random Forest (RF) 99.76 % and Na & iuml;ve Bayes (NB) 98.66% respectively. We believe that this study paves the way for further research, offering a framework for identifying cardiac health conditions through machine learning techniques.
引用
收藏
页数:18
相关论文
共 50 条
  • [1] NON-INVASIVE MONITORING IN THE PATIENT WITH HEART-DISEASE
    GRAVENSTEIN, JS
    CLEVELAND CLINIC QUARTERLY, 1981, 48 (01): : 37 - 43
  • [2] Non-Invasive Health Monitoring System (NIHMS)
    Doyle, T. E.
    Kalsi, M.
    Aiyush, B.
    Yousuf, J.
    Waseem, O.
    IEEE TIC-STH 09: 2009 IEEE TORONTO INTERNATIONAL CONFERENCE: SCIENCE AND TECHNOLOGY FOR HUMANITY, 2009, : 703 - 707
  • [3] A non-invasive monitoring system
    Hancock, Christopher Paul
    Chaudhry, Sabih
    2007 EUROPEAN MICROWAVE CONFERENCE, VOLS 1-4, 2007, : 313 - 316
  • [4] INVASIVE OR NON-INVASIVE MONITORING
    HUGENHOL.PG
    HEIKKILA, J
    HAGEMEIJ.F
    ARNTZENI.AC
    POOL, J
    PALADINO, D
    CIRCULATION, 1972, 46 (04) : 75 - &
  • [5] Development of Non-Invasive Ventilator for Homecare and Patient Monitoring System
    Menniti, Michele
    Lagana, Filippo
    Oliva, Giuseppe
    Bianco, Maria
    Fiorillo, Antonino S.
    Pullano, Salvatore A.
    ELECTRONICS, 2024, 13 (04)
  • [6] A Non-Invasive Remote Health Monitoring System using Visible Light Communication
    Al-Qahtani, Abdulla
    Al-hajri, Hamad
    Al-kuwari, Saad
    Al-yaarabi, Naseer
    Al-hababi, Abdulrahman
    Al-kubaisi, Essa
    Ahmed, Abdulla
    Kashef, Mohamad
    Abbasi, Qammer H.
    2015 2ND INTERNATIONAL SYMPOSIUM ON FUTURE INFORMATION AND COMMUNICATION TECHNOLOGIES FOR UBIQUITOUS HEALTHCARE (UBI-HEALTH TECH), 2015,
  • [7] Heart Rate Monitoring by using Non-invasive Wearable Sensor
    Maria, Aileni Raluca
    Pasca, Sever
    Strungaru, Rodica
    2017 IEEE INTERNATIONAL CONFERENCE ON E-HEALTH AND BIOENGINEERING CONFERENCE (EHB), 2017, : 587 - 590
  • [8] Non-Invasive Heart Rate Monitoring System using Giant Magneto Resistance Sensor
    Kalyan, Kubera
    Chugh, Vinit Kumar
    Anoop, C. S.
    2016 38TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2016, : 4873 - 4876
  • [9] A non-invasive telemetric heart rate monitoring system based on phonocardiography
    Torres-Pereira, L
    Ruivo, P
    Torres-Pereira, C
    Couto, C
    ISIE '97 - PROCEEDINGS OF THE IEEE INTERNATIONAL SYMPOSIUM ON INDUSTRIAL ELECTRONICS, VOLS 1-3, 1997, : 856 - 859
  • [10] NON-INVASIVE MONITORING
    Turmelle, Michael
    JOURNAL OF HOSPITAL MEDICINE, 2010, 5 : 58 - 58