Continuum absorption by water vapor in the 8–12 and 3–5 μm atmospheric transparency windows

被引:4
作者
T. E. Klimeshina
Yu. V. Bogdanova
O. B. Rodimova
机构
[1] V.E. Zuev Institute of Atmospheric Optics, Siberian Branch, Russian Academy of Sciences, pl. Akademika Zueva 1, Tomsk
[2] Tomsk State Pedagogical University, pr. Komsomol’skii 75, Tomsk
关键词
Asymptotic Theory; Water Vapor Absorption; Transparency Window; Continuum Absorption; Classical Potential;
D O I
10.1134/S102485601201006X
中图分类号
学科分类号
摘要
Water vapor absorption coefficients, obtained earlier within the framework of the asymptotic theory of line wings, are used for calculation of the continuum absorption in the frequency region between 0 and 3500 cm−1. The CKD continuum is compared with the continuum, found with the use of the asymptotic line wing theory. © 2012, Pleiades Publishing, Ltd.
引用
收藏
页码:71 / 76
页数:5
相关论文
共 22 条
  • [1] Clough S.A., Kneizys F.X., Davies R.W., Line Shape and the Water Vapor Continuum, Atmos. Res., 23, 3-4, pp. 229-241, (1989)
  • [2] Clough S.A., Shephard M.W., Mlawer E.J., Delamere J.S., Iaconj M.J., Cady-Pereira K., Boukabara S., Brown P.D., Atmospheric Radiative Transfer Modelling: a Summary of the AER Codes, J. Quant. Spectrosc. and Radiat. Transfer., 91, 2, pp. 233-244, (2005)
  • [3] Nesmelova L.I., Rodimova O.B., Tvorogov S.D., Spectral Line Profile and Intermolecular Interaction, (1986)
  • [4] Burch D.E., Gryvnak D.A., Patty R.R., Bartky C.E., Absorption of Infrared Radiant Energy by CO<sub>2</sub> and H<sub>2</sub>O. IV. Shapes of Collision-Broadened CO<sub>2</sub> Lines, J. Opt. Soc. Amer., 59, 3, pp. 267-280, (1969)
  • [5] Thomas M.E., Nordstrom R.J., Line Shape Model for Describing Infrared Absorption by Water Vapor, Appl. Opt., 24, 21, pp. 3526-3530, (1985)
  • [6] Nesmelova L.I., Rodimova O.B., Tvorogov S.D., Water Vapor Absorption Coefficients at Different Temperatures, Optical Spectroscopy and Frequency Standards, (2004)
  • [7] Paynter D.J., Ptashnik I.V., Shine K.P., Smith K.M., McPheat R.M., Williams R.G., Laboratory Measurements of the Water Vapor Continuum in the 1200–8000 cm<sup>−1</sup> Region between 293 K and 351 K, J. Geophys. Res., 114, 11, (2009)
  • [8] Ptashnik I.V., Smith K.M., Shine K.P., Newnham D.A., Laboratory Measurements of the Water Vapor Continuum in Spectral Region 5000–5600 cm<sup>−1</sup>: Evidence for Water Dimmers, Quart. J. Roy. Meteorol. Soc., 130, 602, pp. 2391-2408, (2004)
  • [9] Ptashnik I.V., Evidence for the Contribution of Water Dimers to the Near-IR Water Vapour Self-Continuum, J. Quant. Spectrosc. and Radiat. Transfer., 109, 5, pp. 831-852, (2008)
  • [10] Kjaergaard H.G., Garden A.L., Chaban G.M., Gerber R.B., Matthews D.A., Stanton J.F., Calculation of Vibrational Transition Frequencies and Intensities in Water Dimer: Comparison of Different Vibrational Approaches, J. Phys. Chem., A, 112, 18, pp. 4324-4335, (2008)