System Maps for the Retention of Neutral Compounds on an Electrostatic-Shielded Reversed-Phase Column

被引:0
作者
Sanka N. Atapattu
Kevin R. D. Johnson
Colin F. Poole
机构
[1] CanAm Bioresearch Inc.,Department of Chemistry
[2] Wayne State University,undefined
来源
Chromatographia | 2019年 / 82卷
关键词
Reversed-phase liquid chromatography; Retention; Selectivity; Solvation parameter model; System maps; Octadecylsiloxane-bonded silica stationary phase; Positive shield; Electrostatic shield; Steric shield;
D O I
暂无
中图分类号
学科分类号
摘要
The system constants of the solvation parameter model are used to prepare system maps for the retention of small neutral compounds on an octadecylsiloxane-bonded positive shield porous silica stationary phase (Luna Omega PS C18) for aqueous mobile phases containing 10–70% (v/v) methanol or acetonitrile. Electrostatic interactions (cation exchange) for weak bases were observed using acetonitrile–water but not methanol–water mobile phases at a similar level to a sterically shielded octadecylsiloxane-bonded silica column (Kinetex XB-C18). The system constants of the solvation parameter model and retention factor correlation plots for varied compounds indicated that the Luna Omega PS C18 stationary phase was (near) selectivity equivalent to the diisobutyloctadecylsiloxane-bonded superficially porous silica column Kinetex XB-C18. No specific interactions related to the embedded charged/chargeable functional group were observed compared with other high-purity type-B silica octadecylsiloxane-bonded stationary phases for typical reversed-phase separation conditions with unbuffered mobile phases.
引用
收藏
页码:799 / 808
页数:9
相关论文
共 100 条
  • [1] Unger KK(2012)Adsorbents and columns in analytical high-performance liquid chromatography: a perspective with regard to development and understanding J Sep Sci 35 1201-1212
  • [2] Liapis AI(2016)Recent advances in materials for stationary phases of mixed-mode high-performance liquid chromatography Trends Anal Chem 80 495-506
  • [3] Wang L(2018)Chromatographic test methods for characterizing alkylsiloxane-bonded silica columns for reversed-phase liquid chromatography J Chromatogr B 1092 207-219
  • [4] Wei W(2016)Chromatographic methods enabling the characterization of stationary phases and retention prediction in high-performance liquid chromatography and supercritical fluid chromatography J Sep Sci 39 115-131
  • [5] Xia Z(2015)The hydrophobic subtraction model of reversed-phase column selectivity Adv Chromatogr 50 297-376
  • [6] Ju X(2007)Description and comparison of chromatographic methods for packed column classification J Chromatogr A 1158 329-360
  • [7] Xia ZZ(2017)Applications of the solvation parameter model in reversed-phase liquid chromatography J Chromatogr A 1486 2-19
  • [8] Poole CF(2002)Column selectivity from the perspective of the solvation parameter model J Chromatogr A 965 263-299
  • [9] Sykora D(2016)Mixed-mode chromatography in pharmaceutical and biopharmaceutical applications J Pharm Biomed Anal 128 73-88
  • [10] Vozka J(2011)Mixed-mode chromatography and its applications to biopolymers J Chromatogr A 1218 8813-8825