Fixation techniques and stem dimensions in hinged total knee arthroplasty: a finite element study

被引:0
作者
Bilal Farouk El-Zayat
Thomas J. Heyse
Nelson Fanciullacci
Luc Labey
Susanne Fuchs-Winkelmann
Bernardo Innocenti
机构
[1] University Hospital Marburg,Center of Orthopaedics and Traumatology
[2] University of Florence,Department of Mechanics and Industrial Technology
[3] KU Leuven,Mechanical Engineering Technology TC
[4] Université Libre de Bruxelles,BEAMS Department (Bio Electro and Mechanical Systems)
来源
Archives of Orthopaedic and Trauma Surgery | 2016年 / 136卷
关键词
Stem length; Hinged total knee arthroplasty; Finite element model; Cemented; Press fit;
D O I
暂无
中图分类号
学科分类号
摘要
引用
收藏
页码:1741 / 1752
页数:11
相关论文
共 50 条
[31]   Explicit Non-linear Finite Element Analysis for Prediction of Primary Stability in Uncemented Total Hip Arthroplasty [J].
Ovesy, Marzieh ;
Zysset, Philippe K. .
COMPUTER METHODS, IMAGING AND VISUALIZATION IN BIOMECHANICS AND BIOMEDICAL ENGINEERING II, 2023, 38 :128-142
[32]   A three-dimensional finite element model of a human knee joint - A preliminary study [J].
Tan, S. H. N. ;
Li, J. Z. ;
Cheong, C. H. ;
Lee, P. V. S. .
PROCEEDINGS OF THE FIFTH IASTED INTERNATIONAL CONFERENCE ON BIOMECHANICS, 2007, :131-134
[33]   The assessment of implant shape-dependent failure mechanisms in primary total hip arthroplasty using finite element analysis [J].
Kazemirad, Siavash ;
Yazdi, Mohammad Ali .
COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING, 2025, 28 (06) :750-763
[34]   Biomechanical Comparison of Four Different Atlantoaxial Posterior Fixation Constructs in Adults A Finite Element Study [J].
Chun, Dong Hyun ;
Yoon, Do Heum ;
Kim, Keung Nyun ;
Yi, Seong ;
Shin, Dong Ah ;
Ha, Yoon .
SPINE, 2018, 43 (15) :E891-E897
[35]   Comparative Biomechanical In Vitro Study of Different Modular Total Knee Arthroplasty Revision Stems With Bone Defects [J].
Guttowski, Dario ;
Polster, Valerie ;
Huber, Gerd ;
Morlock, Michael M. ;
Pueschel, Klaus ;
Nuechtern, Jakob .
JOURNAL OF ARTHROPLASTY, 2020, 35 (11) :3318-3325
[36]   Similar survival between uncemented and cemented fixation prostheses in total knee arthroplasty: a meta-analysis and systematic comparative analysis using registers [J].
Wang, Hongchuan ;
Lou, Hua ;
Zhang, Huiwei ;
Jiang, Junwei ;
Liu, Kai .
KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2014, 22 (12) :3191-3197
[37]   Similar survival between uncemented and cemented fixation prostheses in total knee arthroplasty: a meta-analysis and systematic comparative analysis using registers [J].
Hongchuan Wang ;
Hua Lou ;
Huiwei Zhang ;
Junwei Jiang ;
Kai Liu .
Knee Surgery, Sports Traumatology, Arthroscopy, 2014, 22 :3191-3197
[38]   Biomechanical Effect of Constraint in Lumbar Total Disc Replacement A Study With Finite Element Analysis [J].
Chung, Sang Ki ;
Kim, Young Eun ;
Wang, Kyu-Chang .
SPINE, 2009, 34 (12) :1281-1286
[39]   Effects of anterior offsetting of humeral head component in posteriorly unstable total shoulder arthroplasty: Finite element modeling of cadaver specimens [J].
Lewis, Gregory S. ;
Conaway, William K. ;
Wee, Hwabok ;
Kim, H. Mike .
JOURNAL OF BIOMECHANICS, 2017, 53 :78-83
[40]   Biomechanical study of using patient-specific diaphyseal femoral cone in revision total knee arthroplasty (rTKA) [J].
Nourishirazi, Reza ;
Moradkhani, Ghazaleh ;
SharafatVaziri, Arash ;
Nematy, Hamidreza ;
Shayan-moghadam, Ramin ;
Karimpour, Morad .
JOURNAL OF ORTHOPAEDICS, 2024, 57 :65-71